Page 1: ... COOKTOP SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WAR...

Page 2: ... cooktop should be installed away from strong draft areas such as windows doors fans or strong heating vents The cooktop should be located for convenient use in the kitchen Use the countertop opening dimensions that are given with these Installation Instructions Given dimensions are minimum clearances and provide 0 0 cm clearance Grounded electrical supply is required See Electrical Requirements s...

Page 3: ... connection and wire size are adequate and in conformance with the CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No O M91 1atest edition and all local codes and ordinances A copy of the above code standards can be obtained from CSA International 178 Rexdale Boulevard Toronto Ontario Canada M9W 1R3 A A Model serial number plate The cooktop is rated 240 volt This cooktop does not ...

Page 4: ...or more people place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to avoid scratching the countertop Insert bottom of mounting clip into bottom of pocket and push top over top of pocket to snap into place _ _ _ _ 0 II I CI 101 Electrical Shock Haz...

Page 5: ...rs 7 Connect the green or bare ground wire from the cooktop cable to the green or bare ground wire in the junction box using the UL listed wire connectors 8 Put a UL listed wire connector on the end of the white wire from the power supply NOTE Do not connect the bare ground wire to the neutral white wire in the junction box 9 Install junction box cover 10 Reconnect power 3 Wire Cable from Power Su...

Page 6: ... information see the Cooktop Care section oftheUse andCare Guide 5 Read the Cooktop Use section inthecooktop Use and Care Guide 6 Reconnect power NOTE Ifthecooktop does notwork after turning onthepower check thatacircuit breaker hasnottripped orahousehold fuse hasnotblown See Troubleshooting section intheUse and Care Guide forfurther information If you need Assistance or Service Please reference t...

Page 7: ...ssible de d6cbs ou de blessure grave si vous ne suivez pas les instructions Tous les messages de securite vous diront quel est le danger potentiel et vous disent comment reduire le risque de blessure et ce qui peut se produire en cas de non respect des instructions EXIGENCES D INSTALLATION Rassembler les pieces necessaires avant d entreprendre I installation Lire et observer les instructions fourn...

Page 8: ...terre est necessaire Voir la section Specifications electriques IMPORTANT Pour eviter tout dommage consulter le constructeur de la maison ou le fabricant de placards pour determiner si les materiaux utilises peuvent subir un changement de couleur une destratification ou autres dommages Dimensions du produit C A 20 51 0 cm B 24 61 0 cm C 1 4 0 cm A 23 60 0 cm B Zone de matiere combustible au dessus...

Page 9: ...dessus contacter CSA International 178 Rexdale Boulevard Toronto Ontario Canada M9W 1R3 A A Plaque signal_tique La capacite nominale de la table de cuisson est de 240 volts La table de cuisson ne comporte pas de conducteur neutre blanc La table de cuisson doit _tre raccordee directement au boiler de connexion par I intermediaire d un c ble flexible conducteur de cuivre avec blindage ou gaine non m...

Page 10: ... que les boutons ne reposent pas sur le polystyrene 2 Inserer les attaches de montage fournies dans les 4 poches situ6es le long des parois du cadre metallique sous la surface en verre InsUrer le bas de I attache de montage dans la poche inf_rieure et enfoncer le dessus de I attache sur le sommet de la poche pour I embofter Table de cuisson sur four encastr6 sous comptoir 1 A I aide d au moins 2 p...

Page 11: ... I afimentation _lectrique B Conducteur rouge depuis I afimentation _lectrique C Conducteur blanc depuis la table de cuisson D Conducteurs verts ou nus de fiaison _ la terre depuis le c ble de la table de cuisson E C ble _ 3 conducteurs depuis la table de cuisson E BoTtier de connexion G Conducteur blanc depuis I afimentation _lectrique H Connecteur de ills homologation UL I Conducteurs noirs J Co...

Page 12: ...sson au conducteur blanc neutre dans le boltier de connexion avec les connecteurs de ills homologation UL Installer le couvercle du boltier de connexion Reconnecter la source de courant electrique 1 Verifier que toutes les pieces sont maintenant installees S il reste une piece passer en revue les differentes etapes pour decouvrir laquelle aurait et6 oubliee 2 Verifier la presence de tousles outils...