background image

Part No. 4455046 Rev. A

Installation Instructions

IMPORTANT:
Installer: 
Leave Installation 
Instructions with the homeowner.
Homeowner: Keep Installation 
Instructions for future reference.
Save Installation Instructions for local
electrical inspector’s use.

Write down the model and serial numbers
before installing cooktop.

Both numbers are on the model/serial
rating plate, located on the underside of
the cooktop burner box.

Model #___________________________

Serial # ___________________________

Questions regarding features,
operation, performance, parts or
service? Call 1-800-422-1230 or visit
our web site at www.kitchenaid.com.

IMPORTANT:
Read and save these
instructions.

36" (91.4 cm) Professional Gas Cooktop

for residential use only

OFF

OFF

OFF

OFF

OFF

OFF

Backguard 

(required for some installations)

For the way it’s made

®

®

Summary of Contents for KGCP467HSS0

Page 1: ...ing cooktop Both numbers are on the model serial rating plate located on the underside of the cooktop burner box Model ___________________________ Serial ___________________________ Questions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 36 91 4 cm Professional Gas Cooktop for res...

Page 2: ...rances specified on the model serial rating plate The model serial rating plate can be found on the underside of the cooktop burner box It is recommended that an overhead vent hood be used with this cooktop For island installations a 48 122 cm hood is recommended Check location where cooktop will be installed The location should be away from strong draft areas such as windows doors and strong heat...

Page 3: ... 8 18 1 cm 7 8 22 2 mm 2 3 16 55 6 mm 1 3 16 30 1 mm side view of cooktop gas inlet is located 1 7 8 4 8 cm from back of burner box and 4 7 8 11 7 cm in from L H side of burner box 9 22 9 cm 26 1 4 66 7 cm 36 91 4 cm long 3 prong ground type power supply cord backguard shown or island trim see P 4 and 7 22 55 9 cm ...

Page 4: ... 1 25 4 mm clearance to the back wall use the optional stainless steel island trim included with the cooktop to cover the backguard mounting flanges Provide an 8 x 8 20 3 cm x 20 3 cm cutout in left rear corner of cutout enclosure to provide clearance for gas inlet power supply cord and to allow the rating label to be visible Copies of the standards listed may be obtained from National Fire Protec...

Page 5: ...rican National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CANI B149 1 or 2 Explosion Hazard Use a new AGA or CSA approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 water column Examples of a qualified person include licensed heating personnel authorized gas co...

Page 6: ...t system at test pressures greater than 1 2 psig 3 5kPa Testing below 1 2 psi 3 5 kPa or 14 inches 35 6 cm W C gauge or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Electrical Shock Hazard Plug into a grounded 3 ...

Page 7: ...ill need to determine the fittings required depending on your installation 7 Attach the backguard or island trim as required for your installation Attachment screws are in the literature package 8 Place cooktop completely into cutout Note The cooktop must be level for best cooking performance 9 If the pressure regulator and flexible stainless steel gas supply were not assembled in Step 3 complete ...

Page 8: ...ompany Maintenance If removing the cooktop is necessary for maintenance shut off gas supply Disconnect the gas and electric supply After disconnecting the gas and electric supply finish removing the cooktop Generally the cooktop does not need to be removed for servicing 8 16 Push in and turn each control knob to the LO or simmer setting The LO setting of each burner has been factory set to the low...

Page 9: ...S Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing BLK BLK PLUG LINE 1 4 WIDE BLADE GROUND CONNECT 250 TERMINALS GROUND SPARK MODULE 120 VAC 60 Hz 1 PHASE 15 AMP VALVE SWITCHES IGNITOR ELECTRODES ROUND BLADE Part No 4455046 Rev A 2000 KitchenAid Registered Trademark Trademark of K...