background image

Ice Maker

PRODUCT MODEL NUMBERS

CABINET OPENING DIMENSIONS

KUIA18NNJ
KUIA18PNL
KUIC18NNT

KUIS18NNT
KUIC18PNT
KUIS18PNT

Electrical:

115 volt, 60 Hz, AC only, 15 or 20

amp grounded circuit is required. A time-delay
fuse or circuit breaker and separate circuit is
recommended.

Water:

A cold water supply with water pressure

of between 30 and 120 psi (207 and 827kPa) is
required to properly operate the ice maker. 

Drain:

Either a gravity drain system or a drain

pump system to carry water to an existing drain.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 2313820A

05-04-07

®

14

¹⁄₂

"

(36.8 cm)

18"

A

B

(45.7 cm)

24"

(60.1 cm)

9"

(22.9 cm)

28

¹⁄₂

"

(72.4 cm)

34"

(86.4 cm)

Min.

34

¹⁄₂

"

(87.6 cm)

Max.

3

¹⁄₂

"

(8.9 cm)

A. Recommended

location for electrical
and plumbing fixtures.

B. Floor level

REAR VIEW

A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)

C. Water supply line

A

C

B

SIDE VIEW 

1" (2.5 cm)

20" (50.80 cm)

1

⁷⁄₈

"

(1.9 cm)

B

D

C

A

2" - 1

¹⁄₂

"

(5 cm - 3.8 cm)

A. Drain  hose
B. 1" (2.54 cm) air gap

C. PVC drain reducer
D. Center of drain should be 20" (50.8 cm) from front of door, 

with or without the 

³⁄₄

" (1.91 cm) panel on the door. The 

drain should also be centered from left to right (8

¹³⁄₁₆

"

from either side of the ice maker). 

Drain lines must have a minimum of 5⁄8" 
(15.88 mm) inside diameter.

Drain lines must have a 1" drop per 48" (2.54 cm
drop per 122 cm) of run or 1⁄4" drop per 12" 
(6.35 mm per 30.48 cm) of run and must not have
low points where water can settle.

The floor drains must be large enough to
accommodate drainage from all drains.

The ideal installation has a standpipe with a 1-1⁄2"
(3.81 cm) to 2" (5.08 cm) PVC drain reducer installed
directly below the outlet of the drain tube as shown.
You must maintain a 1" (2.54 cm) air gap between the
drain hose and the standpipe.

It may be desirable to insulate the drain line
thoroughly up to the drain inlet.

DRAIN REQUIREMENTS

33

 

¹³⁄₁₆

"

(85.9 cm)
Min.

34

 

⁵⁄₁₆

"

(87.1 cm)
Max. with 
leveling 
legs fully 
extended

17

 

¹³⁄₁₆

"

(45.2 cm)

25

 

⁵⁄₈

"

(65.1 cm)

23

 

¹⁄₈

"

(58.7 cm)

PRODUCT DIMENSIONS

Reviews: