ø90mm

A. 

Cut a hole 90 mm diameter in the decking

or board ensuring it does not infringe with
any gas/water pipes or electrical cables that
may be hidden below the surface. 

B. 

With the 4 x machine screws (supplied) fix

the 2 x spring clips (supplied) to the body. 

Ensure the clips are pointing out  

C.

Connect the pre-installed flexible cable to

a suitable joint box ensuring correct polarity
is observed. 
BROWN- LIVE. BLUE-NEUTRAL. 

The joint box must be IP65 or above rated if
used externally or underground

D. 

Finally, push the fitting into the decking or

board

Check for correct operation.

DECKING INSTALLATION

LN

LN

A

B

C

D

PLEASE NOTE: IF CABLE IS BURIED UNDERGROUND IT IS ADVISED THAT A
SUITABLE NON -CORROSIVE CONDUIT IS USED.

INSTALLATION  & MAINTENANCE MANUAL

LEDM08B - LEDM08W 

230V

50Hz

IP

6

5

dim

02

IP65 LED  RECESSED LUMINAIRE

LEDM08B_LEDM08W_INSTRUCTIONS_Layout 1  15/11/2013  09:54  Page 1