background image

    Spec 

Sheet 

    Accessories 

for 

the 

PYROMAT-ECO 

Functions of the boiler 

 

 

Köb Holzheizsysteme GmbH, Flotzbachstr. 33,  A-6922 Wolfurt, Tel. +43/5574/6770-0, Fax 65707, E-Mail: office@kob.cc 

Subject to technical changes 

2200-1

2009-03-01_GB

Burner Slide-out System 

[Art. No. KPM-E-OBA / 7387410]

 

 
For left- or right-hand side installation on the PYROMAT; manual retraction of the burner against spring pressure; when 
pulled out, a weighted shutter closes automatically, thus protecting the burner from soiling; protected by a limit switch. 
 
Flange diameter, inside:   

128 mm 

Hole circle diameter: 

 

150 mm 

Retracting stroke:  

160 

Weight without burner: 

 

24 kg 

 
Scope of delivery: 

-

 

1 limit switch mounted on slide-out system 

-

 

1 limit switch uninstalled, for installation by the customer on filler lid 

 

limit switch

weighted shutter

boiler casing

insulation

burner when moved in
(oil-burning operation)

burner when moved out

with shutter closed

(wood-burning operation)