     I. INTRODUCTION
This Uninterruptible Power Supply (UPS) is a high quality product 

designed to protect your computer system against information loss and 

damages to computer peripherals like monitors and modems in case of 

a blackout.

All Koblenz UPS models feature RJ11 / RJ45 telephone jacks to protect 

your computer modem against voltage spikes and surges coming 

through your telephone line (cable not included). Selected models have 

coaxial cable protector (see table 1).

USB/R models (see table 1) also include an integrated USB port that with 

the Koblenz Protek Software gives you on screen warnings in case of 

power failure (cable not included). If the blackout continues and your 

computer is unattended, the Koblenz Protek Software will save and 

close your open files and safely shut down your computer. 

You can download the Koblenz Protek Software free of charge at 

www.koblenz-protek.com

 

   

 II. INSTALLATION AND USE

1. Place the UPS to avoid:

  a. Direct sunlight

  b. Excessive heat

  c. Excessive humidity or contact with liquids

2. Plug the UPS directly into a properly grounded 3-prong outlet. The UPS 

begins charging when connected to utility power and turned on. Charge 

the UPS 24 hours before using for the first time.

3. Turn off your UPS. Plug your equipment into the battery backup outlets. 

Do not plug surge protectors or power strips into battery backup 

outlets.

a. To make sure that your computer or video equipment is protected 

against a power failure it is important to know its volt / ampere rating 

and compare it with your UPS capacity (see table 3). You may plug 

one or more pieces of equipment into the UPS making sure that the 

total power requirement does not exceed the UPS capacity.

b. If the UPS is overloaded, a red light will flash and the UPS will beep, 

this will turn off when the extra load is disconnected.

c. Battery backup plus surge protection outlets (silver).

   These outlets should be used for sensitive equipment such as 

computers, monitors and external drives. Battery power is 

automatically provided in case of power outage. Power (utility or 

battery) is not supplied to these outlets when the UPS is switched off.

     Do not plug in laser printers to battery backup outlets, if so the UPS 

warranty is voided.

d. Surge Protection Outlets.

    These outlets should be used for all others peripherals such a printer, 

scanner, fax machine, etc. These outlets do not provide power 

during a power outage.

4. Hook up your telephone line to the UPS jack marked "TEL LINE". Using a 

regular telephone cable (not included) hook up the UPS "MODEM" jack to 

your computer's LINE IN jack. Finally, connect your telephone or fax to the 

computer's TELEPHONE / LINE OUT jack (figure A).

5. Turn on your UPS, when the ON LINE light is on the UPS is ready.

6. If you want to install the Koblenz Protek Software connect a USB cable 

(not included) from the USB port in the UPS to the computer. Insert the 

CD in your computer and follow the instructions. Only models USB/R.

* In case of a blackout:

All models will emit a beep and the "ON BATTERY" light will flash. As the 

battery depletes the pace of the beep will become faster.

If you have installed the Koblenz Protek Software and the USB cable, you 

will also receive a warning message on your computer screen and the 

software will automatically save your files and shut down your system 

before the battery runs out.

     III. STATUS INDICATORS
Placed on the front panel to indicate UPS status.

1. On Line (green): This indicator is lit when there is utility power.

2. On Battery (red): This indicator is lit when the UPS battery is powering the 

battery backup outlets.

3. Battery Level: If the light is green the battery is totally charged; if it is 

yellow, the battery has less than the 50% of the charge and if it is red, the 

UPS is almost run out of battery.

4. Overload (red): This indicator is lit when the equipment connected to 

battery backup outlets (silver) consume more than the UPS capacity. 

Remove one or more pieces of equipment to the surge protection outlets 

until the light and the beep turn off.

5. Replace Suppressor (yellow): This indicator is lit when the surge 

suppressor is burnt out. It is necessary to take the UPS to a service center 

or to connect a surge suppressor to it. The UPS continues working 

normally but it does not protect against spikes any more.

6. Replace Battery (red): This indicator is lit when the battery is near to the 

end of its useful life. The battery should be replaced. Failure to replace the 

battery may result in insufficient runtime during a power outage.

     IV. BATTERY
1. The battery automatically recharges whenever the UPS is plugged into an 

electrical outlet and turned it on.

2. Average battery life is 2 to 3 years.

3. To buy a new battery, call toll free: 1-800-548-5741.

4. Koblenz batteries are sealed and maintenance free.

     V. SAFETY
1. Keep your Koblenz UPS away from moisture and liquids.

2. Do not expose the UPS to direct sunlight.

3. Do not use for medical or life support equipment.

4. Plugging any domestic appliance (i.e. blender, iron, refrigerator, etc.) into 

the UPS will void  the warranty.

5. Black outlets should not be used to plug in laser printers.

Congratulations!

 

You have just acquired a Koblenz UPS. 

Please read this manual carefully before operating your 

new UPS. Keep manual for further references.

Operating Instruction Manual

UPS Battery Backup.

For computer and TV equipment.

Models: 12007- USB/R

TEL. LINE/MODEM

in                         out

COAXIAL LINE

SURGE PROTECTED OUTLETS. NOT BA

TTER

Y SUPPORTED

BA

TTER

Y PROTECTED PLUS   SURGE PROTECTED OUTLETS

W

ARNING: DO NOT CONNECT 

A

 LASER PRINTER

COMPUTER LOAD ONL

Y 120V

AC 60 HZ

Æ

in                 out

INPUT

120 V - 60 HZ

CIRCUIT BREAKER

PUSH TO RESET

USB PORT

ON

BATTERY

BATTERY

LEVEL

REPLACE

BATTERY

ON

LINE

REPLACE

SUPRESSOR

OVERLOAD

professional 500 

VA

Summary of Contents for 12007-USB

Page 1: ... LINE OUT jack figure A 5 Turn on your UPS when the ON LINE light is on the UPS is ready 6 If you want to install the Koblenz Protek Software connect a USB cable not included from the USB port in the UPS to the computer Insert the CD in your computer and follow the instructions Only models USB R In case of a blackout All models will emit a beep and the ON BATTERY light will flash As the battery de...

Page 2: ...rt Cable included lbs 12007 USB R 1200 800 4 3 Yes Yes Yes Yes 120 V 120 V 60 24 2 2 VIII TYPICAL RUN TIME MINUTES TABLE 2 IX SAMPLE EQUIPMENT REQUIREMENTS TABLE 3 Model With PC and 15 monitor Battery reserve Pentium III with 17 monitor 150 VA continuous beep alarm Pentium IV with 17 monitor 150 VA 12007 USB R Up to 85 minutes 2 3 minutes Mac G3 with 19 monitor 200 VA X DRAWING A return it freight...

Page 3: ...ría Si la batería está totalmente cargada el tono intermitente es pausado cuando la batería está en un nivel bajo el tono cambia a intermitente rápido una vez que la batería está a punto de agotarse el tono cambia a forma continua En caso de que tenga instalado el Koblenz Protek Software y conectado el cable USB no incluido aparecerá en el monitor el siguiente mensaje BATERÍA ACTIVADA y el softwar...

Page 4: ... PROTECCIÓN PARA LA LÍNEA TELEFÓNICA DIBUJO A XI GARANTÍA Koblenz Eléctrica S A de C V garantiza este producto por un término de 5 años en todas sus partes 2 años en la batería y mano de obra contra cualquier defecto de fabricación a partir de la fecha de entrega Tratándose de productos que requieran de enseñanza o adiestramiento en su manejo o instalación de aditamentos accesorios implementos o d...

Reviews: