background image

KOBOLD Instruments, Inc. 1801 Parkway View Drive, Pittsburgh PA 15205
Telephone: (412) 788-2830 · FAX: (412) 788-4890 www.koboldusa.com

Power Requirements:

Two Wire Switching:

24 to 240 VAC/VDC 50-60 Hz.

Three Wire Switching: 24 VDC
SPDT Relay:

24 VDC or 110 VAC depending 

on model number

Solid State Switch Characteristics:

Max. Current:

500 mA.

Min. Current:

7.5 mA.

Leakage Current:

3 mA.

Voltage Drop:

2.5 Volts @ 500 mA.
5.0 Volts @ 20 mA.
10 Volts @ 7.5 mA.

SPDT Relay Characteristics:

10A @ 110 VAC, 
5A resistsive/2A inductive 
@ 24 VDC

Switching Delay:

Wet to Dry:

500 mSec.

Dry to Wet:

50 mSec.

Fluid Temperature Range:

-40 to 270°F

Max. Ambient Temp:

160°F with 200°F Fluid
120°F with 270°F Fluid

Max. Operating Pressure:

1000 PSIG @-40 to 120°F
760 PSIG @ 120 to 270°F

Electrical Protection:

NEMA 4/IP 65

Installation

In order to ensure a leak tight seal, a thread sealant such as 
Teflon tape should be used on the probe threads prior to instal-
lation.

The NWS should be installed with the cable penetration facing downward. This will 
prevent water from settling into the cable gland thereby minimizing leakage into 
the electronics. After the unit is installed in its fitting the housing can be roatated to 
achieve the proper cable gland orientation

Special Note:

To ensure reliable operation, the series NWS should be 
installed in the vessel with the forks of the sensing probe in the 
three o’clock and nine o’clock position. The Installation nut on 
the NWS has a slotted positioning guide which can be used to 
ensure that the probe is installed in the proper position (See 
Fig. 2).

Specifications

Series NWS Fork Level switch

Installation/Operation Instructions

Description

KOBOLD’s Series NWS is a compact, vibrating 
fork level switch which is suited for use with 
non-viscous and viscous liquids as well as 
many types of fine granular solids. The switch 
employs an forked probe which vibrates at a 
resonant frequency. When the probe is 
immersed in a medium, the resonant frequency 
is dampened. This frequency shift is sensed by 
a detecting circuit and results in activation of a 
solid state switch or SPDT relay depending on 
the model.The Series NWS can be configured 
either as a two wire or three wire controller and 
is switchable from a normally open to normally 
closed (wet-on or dry-on) switch function. Its 
solid state design uses no moving parts in the 
sensor or switch portions, making the switch 
exceptionally reliable.

Fig. 2: Probe Orientation

The guide slot on the probe installation
nut should be in the 12 O’clock or 6 O’clock
position to ensure that the probe is properly
oriented inside the tank