background image

Instruction Manual

Ionizer Blow Type [DTY-ELK01]

Thank  you  very  much  for  your  purchase  of  the  DTY-ELK01. Although  this 
product  is  not  classified  as  a  high -voltage  device  under  any  electrical 
equipment  standards,  it  uses  a  2000VAC  high  voltage.  Please  read this 
manual diligently in order to handle this unit carefully and correctly. Keep 
this manual in a safe place.

1. Safety Precautions

Because  a  high  voltage  is  used  in  this  product,  improper  use  of  the  unit 
may  cause  an  accident  resulting  in  injury  or  dea th,  or  may  lead  to  a 
malfunction  of the  product. Koganei  will not be  held liable for  any  usage 
outside  the  Product  Specifications  or  for  any  accident  caused  by 
noncompliance with the Safety Precautions.

DANGER

Expresses situations that can be clearly predicted as 
dangerous. If the noted danger is not avoided, it could 
result in death or serious injury.
It could also result in damage or destruction of assets.

WARNING

Expresses situations that, while not immediately 
dangerous, could become dangerous. If the noted danger 
is not avoided, it could result in death or serious injury.
It could also result in damage or destruction of assets.

CAUTION

Expresses situations that, while not immediately 
dangerous, could become dangerous. If the noted danger 
is not avoided, it could result in light or semi-serious injury.
It could also result in damage or destruction of assets.

ATTENTION

While there is little chance of injury, this content refers to 
points that should be observed for appropriate use of the 
product.

1.1

DANGER

Do  not  use  in  locations  where  explosives,  flammables,  or  other  dangerous 
substances are present. This product is not an explosion-proof type unit. Explosion 
or ignition may occur.
When any wiring, installation, or inspection work is to be carried out, make sure that
the unit is disconnected from the power supply, otherwise, an accident, an electrical 
shock or a malfunction may be caused.
Never  attempt  to  remodel  the  product. It  could  result  in abnormal  operation 
leading to injury, electric shock, fire, etc.
Do not splash water on the product. Spraying it with water, washing it, or using it 
underwater  could  result  in  malfunction of  the  product  leading  to  injury,  electric 
shock, fire, etc.
A  high  voltage  is  applied  to  the  discharge  needle. Do  not  allow  any  conductive 
material, including fingers, any part of the body, wires or tools to come close to the 
needle. Otherwise, an electric shock or a malfunction of the unit may occur.

1.2

WARNING

Do not use the product in excess of its specification range. Such use could result 
in  product  breakdowns,  function  stop, damage  or  drastic  reduction  in  the 
operating life.
The  discharge needle  has  a sharp  edge.  Pay  special  attention  to  handling  of  the 
needle, or you may injure yourself.
Always make sure that the air supply is active before turning ON the unit. If the 
air supply is not active when the power supply is applied there may be a build-up 
of ozone inside the unit  due to electrical discharge that could  have an adverse 
effect on the equipment and the environment.
When using the nozzle, do  not point it toward  a person’s body, and particularly 
not toward the face and eyes. You may injure yourself or other persons.

1.3

CAUTION

The  ionizer  generates  ozone  in  the  atmosphere.  Although  the  concentration  will 
become saturated and will not exceed a certain level when a single unit is used, if 
multiple  units  are  used  there  may  be  a  smell  of  ozone.  In  this  case,  increase 
ventilation. However,  putting  your  face  up  against  the  ozone  air  emission  port  to 
check for an ozone smell is not recommended. It could cause injury to the nose or 
throat.

1.4

ATTENTION

When the product can no longer  be used or is no longer  needed, dispose of it 
appropriately as industrial waste.

*  For  any  other  items  of  danger,  warning,  or  caution,  please  refer  to  the  “Safety 

Precautions” in the Catalog for the “Static Electricity Removing Unit: Ionizer” (Catalog 
No. BK-R0001). (Be sure to refer to the latest version of the Catalog.)

2. Product Overview

This  product  is  a  blow  type  ionizer  (a  device  for  eliminating  static  electricity).
This  product  is  helpful  in  quickly  resolving problems  with  static  electricity. 
Ionized  air  quickly  and  efficiently  neutralizes  the  static  electricity  on  charged 
objects,  and  rem oves  dust  attracted  by  the  static  e lectricity.  This  effectively 
controls static electricity problems and dust contamination problems .
You can also select an air-saving type of ionizer that reduces air consumption 
or a low-dust type that suppresses dust generation, depending on uses and 
needs.

3. Contents of the Package

On  receipt  of  the  product,  please  check  the  package  for  any  missing  parts  or 
for  any  abnormality  or dam age that may have  occurred  during delivery before 
using the unit. In case any dam age should be found or any abnormal oper ation 
should  be  observed,  please  contact  the  outlet  (the  agency) at  which  you 
purchased the product, or the nearest Koganei service station.

3.1 Content of Package

Main unit: 1

    ・

Discharge needle unit*

1

: 1

    ・

Mounting bracket: 1

Mounting bracket screws: 2

    ・

Power and signal cable (2 m): 1

Instruction Manual (this booklet): 1

Air-saving nozzle*

1,2

(DTY-ELK01-S only)

* 1. Attached to main unit at time of shipping.

2. For products other than DTY-ELK01-S, the nozzle is not included.         
Please purchase the nozzle separately.

4. Specifications

4.1 List of Specifications

Type

DTY-ELK01

DTY-ELK01-S

DTY-ELK01-L

(Standard)

(Air-saving)

(Low-dust)

Input power source

24VDC ± 5%

Current consumption

70 mA

Output voltage

Approx. 2 kV (High frequency type)

Displays

POWER LED 

(Green)

When the power is ON

H.V LED 

(Blue)

When discharge is in operation

CHECK LED 

(Yellow)

When abnormal discharge occurs 

(H.V LED goes OFF)

ALARM LED 

(Red)

When abnormal function occurs

(H.V LED goes OFF)

Output

Contact point output when CHECK LED and 

ALARM LED are ON

(24V 50 mA MAX Open Drain)

Ionizer ON/OFF control input

At 0V, discharge stops with short-circuited

(No-voltage input, internal drop voltage 0.5V or less)

Ion balance

*1

±15V or less

(at a distance of 50 mm

and air pressure of 0.3 MPa)

Static elimination time

*1,2

0.5 sec or less

0.8 sec or less

0.5 sec or less

Generated ozone volume

0.03 ppm or less

(at a distance of 300 mm 

and air pressure of 0.3 MPa)

Dust volume

-

-

50 particles or 

less

*1,3

Air tube connection diameter

6 quick fitting

Rc1/8

Range of air pressure used

0.05 MPa to 0.5 MPa

Air supply flow volume*

4

   

(ANR)

280 ℓ/min

60 ℓ/min

280 ℓ/min

Media

Air (Clean air devoid of moisture and oil)

Mass

60 g*

5

75 g*

6

66 g*

5

Operating 

environment

Temperature

Humidity

Altitude

0 to 40

C (indoor)

15% to 65% RH (with no condensation)

2000 m or less

Safety approvals

IEC61010-1

(Over voltage category I, Pollution degree 2)

*1. Measured under the measuring conditions specified by Koganei

2. Measurement distance 50 mm, air supply pressure 0.1 MPa, standard 

nozzle in use

3. 0.3 μm or more, 1 cf/min
4. Air supply pressure of 0.5 MPa
5. W hen the bracket and nozzle are not attached.
6. W hen the standard nozzle and bracket are not attached.

5. Appearance

DTY-ELK01 (Standard type)

DTY-ELK01-S (Air-saving type)

DTY-ELK01-L (Low-dust type)