Summary of Contents for PW 1000/LT Series

Page 1: ...Kohler PW 1000 LT 800 2200 VA ...

Page 2: ...or accidental personal or material damage due to any misinterpretation of or accidental errors in this manual 2019 Kohler Uninterruptible Power This manual may not be copied or reproduced without written permission of Kohler Uninterruptible Power PDF ISSUE DATE REVISION SUMMARY TS_602_00A 12 04 2018 First draft copy issued TS_602_00 12 11 2018 First Issue TS_602_01 20 03 2019 Kohler rebranding www...

Page 3: ... electrically live even when the UPS is disconnected from the AC mains DO NOT remove the UPS cover The unit does not contain any user serviceable components and if you remove the cover you will be exposed to potentially hazardous voltages DO NOT insert any object into ventilation holes or other openings The battery circuit is not isolated from the AC input and a hazardous voltage might exist betwe...

Page 4: ...urge protection option 1 2 3 4 5 Description Key AC Input power connector IEC Input fuse UPS Power outlets 4 x IEC USB interface standard RS232 interface option Modem network surge protection option 1 2 3 4 5 Fan 6 Description Symbol Led Red Green Green UPS ON OFF Switch ON System malfunction ON Line mode Flashing Battery mode Load or Battery capacity indicators Indicate the percentage load when t...

Page 5: ...ptimum UPS operation and long service life always install the UPS in a location that meets the following environmental standards The ambient temperature is between 0 C and 40 C A temperature of 20 C is ideal for optimum battery lifespan The ambient humidity does not exceed 90 non condensing The installed location is clean dry and free of excessive dust The UPS must not be installed in direct sunli...

Page 6: ... turn OFF and disconnect the power to the load 4 3 Cold Start function If the utility mains is not available you can start the UPS from its internal battery 1 Press the UPS ON OFF button until the buzzer beeps a The UPS will start and deliver power to the connected load Note The UPS battery will begin to discharge and the utility mains supply must be restored before the battery reaches its fully d...

Page 7: ...inal followed by the red battery positive terminal 6 Carefully withdraw the battery from the case taking care not to short circuit the battery terminals 7 Fit the replacement battery using the above instructions in reverse order Note that it is normal to see a small spark when connecting the new battery 8 Refit the front panel and top cover and secure in place using the four screws located at the ...

Page 8: ...ted securely 3 Check that the utility mains supply is within the UPS specified operating range 4 If the above checks are passed and the UPS is still not operating check the mains supply plug top fuse and the input fuse 2 on the back of the UPS and replace if found to be ruptured Seek trained assistance if the replacement fuse fails immediately the UPS is switched back ON 5 If all of the above are ...

Page 9: ...ry Type and number 12V 9Ah x 1 12V 9Ah x 2 Charging time 4 6 hours recover to 90 capacity Physical Dimensions WxHxD mm 100 x 140 x 192 148 x 198 x 315 Net weight kg 5 5 11 0 12 0 Packing dimensions WxHxD mm 137 x 226 x 321 229 x 302 x 411 Gross weight kg 6 0 12 0 13 0 Environment Humidity 0 90 0 40 C non condensing Noise level Less than 40 dBA at 1 metre from the front of the case Certification Sa...