background image

INSTALLATION INSTRUCTIONS

INTELLIGENT TOILET

                  K-8423A-0

 

 

VEIL

  WALL FACED 

 

•  We appreciate your commitment to Kohler quality. Please take a few minutes before you begin installation to review 
    this manual to become familiar with tools, materials and installation methods. If you encounter any installation or 
    performance problems, please don't hesitate to contact us. Thanks again for choosing Kohler Co.

•  Please follow instructions closely to avoid costly mistakes caused by improper installation. Cover and protect the 
    components and fittings at all times during installation. Flush the plumbing lines before initial use.

•  All information in this manual is based upon the latest product information available at the time of publication. Kohler 
   Co. reserves the rights to make changes in product characteristics, packaging or availability at any time without notice.

• Before continuing, please ensure there is no existing damage to the toilet and that there is suitable space for installation 
   with no interference with other bathroom fixtures such as shower door openings. Before proceeding with installation, 
  ensure there is ample room (approx 600mm) down each side of the pan to allow for servicing.

• To prevent serious damage, do not use corrosive solutions (see back page for care and cleaning information).
  Any use of non-recommended products could void the Kohler warranty.

• This manual includes important care and cleaning information - please save these instructions.

 

Product Functions

 

                     

 

Advantages for the In-wall Water Tank

•  Hands-free flushing                                     
•  Manual dual-flush option
•  Backflow prevention

•  Pre-set water inlet level & flush volume
•  Suitable for either S-trap or P-trap installations

•  Anti-impact, rust-proof, macromolecule water tank reduces the possibility of leakages.
•  Advanced water tank system is able to adjust 4.5/3 litre water discharge. To maintain the 4-star WELS rating, switch    
    off the Auto-flush option.
•  No influence on wall structure, superb sound-proof effectiveness.
•  Easy and quick installation saves time and labour.
•  Easy servicing, wall reconstruction is not required.
•  Sanitary system with no residual waste.
•  Super thin tank body saves installation space and is applicable for all thin mounting walls.

COMPLIANCE

: Ensure installation adheres to local building code & applicable plumbing/electrical standards.

•  The Kohler Veil Intelligent Toilet - Wall Faced (

K-8423A-0

) is WaterMark certified according to ATS 5200.051 

Technical Specification for Plumbing and Drainage Products - Bidet Douche Seats.

•  Installation must comply with AS/NZS 3500.1 Plumbing and Drainage - Water Services and AS/NZS 6400 Water 
Efficient Products - Rating and Labelling.

Backflow Prevention

•  The supplied Dual Check Valve is WaterMark certified according to AS 2845.1 Water Supply - Backflow Prevention 
Devices - Materials, Design and Performance Requirements.

•  Each site must have High Hazard Backflow Prevention installed upstream of the installation.

•  For domestic installations, consult with a Licensed Practitioner (Plumber) before installation.

•  For commercial applications, refer to a Hydraulic Consultant before specification or installation.

      WARNING: Risk of electric shock. Disconnect power before servicing.

      WARNING: Risk of electric shock. Connect only to a properly-grounded, grounding-type receptacle which is 
protected by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD)

      WARNING: Risk of electric shock. This product must be grounded. Connect only to a dedicated 220~240V AC, 
50/60Hz circuit protected with grounded circuit-breaker or grounded electric leak circuit breaker

      WARNING: 10A power supply is required.

     

     

     

     

 

                Kohler Co.     Jan 2018                                                        1                                                    

                          1345889-A02-A

Summary of Contents for VEIL WALL FACED

Page 1: ...r tank reduces the possibility of leakages Advanced water tank system is able to adjust 4 5 3 litre water discharge To maintain the 4 star WELS rating switch off the Auto flush option No influence on wall structure superb sound proof effectiveness Easy and quick installation saves time and labour Easy servicing wall reconstruction is not required Sanitary system with no residual waste Super thin tan...

Page 2: ...let installation is not limited to certain locations It can be hung almost anywhere which affords a far greater use of bathroom space Component information Pan with faceplate 20313A 0 Remote assembly 1235953 Hydro Tower 500 in wall tank 18647A NA Faceplate 1268687 Required tools and materials 19mm spanner or adjustable wrench Blade File Hacksaw Hex key Impact drill Level Screwdriver Rulers measuri...

Page 3: ...rea for installation Reference area for application Remote control Finished wall Finished floor Finished floor 533 438 1027 150 215 1000 900 800 675 80 160 170 Finished wall 208 308 From floor to fixing hole centre 675mm x 438mm x 533mm Height shall be calculated from floor to the top of the product About 48 5Kg 1 40 C 70kPa Dynamic pressure 1600W 1000W 220V 50Hz 4 5L 3L 740kPa Static pressure SPE...

Page 4: ...ibacterial cover Antibacterial seat Bidet nozzle Bidet function detection zone A Hold the edge of toilet bowl and slide out from packaging box WARNING Risk of product damage or personal injury When lifting up the toilet please hold it by the rim Product is heavy please employ a two person lift Fig 3 Fig 4 ...

Page 5: ...of electric shock For plug in installation wall mounted electrical supply Connect only to a properly grounded grounding type circuit which is protected by a Ground Fault Circuit Interrupter GFCI or Earth Leakage Circuit Breaker ELCB WARNING Bathtub and sprinkler head shall be far away from electrical parts e g remote controller power receptacle etc if it is wall hung style water proof or splash pr...

Page 6: ...mm from the floor to the centre of the bowl fixing holes The frame should be installed on top of the bottom plate usually 45mm high Please allow for this height when adjusting the feet Ensure the adjustment is even by using a level and tighten the bolts to set the height IMPORTANT Protect electronic connection point and wires from accidental damage Bowl fixing holes Bidet water supply 1 metre height...

Page 7: ... a drill as shown in Fig A and B Insert coach screws with washers into the installation holes in the framework then tighten Repeat for all screws 4 Tighten screw by wrench as shown in Fig A Tighten screw by wrench as shown in Fig B Kohler Co Jan 2018 7 1345889 A02 A A B Bottom plate Gap for discharge elbow S trap install Coach screw Coach screw Stud Stud Nog Recommend M6x40 coach screw with 3mm wa...

Page 8: ...s clean with no residual debris fouling the inside of the pipeline 7 Place square cover within protection cover of water tank Snap the buckle into the slot and tighten square cover bolts on tank NOTE Square cover has the word TOP on it indicating which surface should face upwards when installed Fig 10 Fig 11 Kohler Co Jan 2018 8 1345889 A02 A ...

Page 9: ... lower end into discharge port Note To allow testing of the cistern for leaks and water level plug the water supply for bidet function 2 Place the bung into the discharge elbow Note Do not lubricate the connection between pan and waste connector Lubricate connection between waste connector and discharge elbow Proceed to Step E on pg10 Discharge elbow Water tank bracket Discharge elbow lower end Di...

Page 10: ...unting bracket to secure E Prepare and finish the wall IMPORTANT 1 When preparing the wall the wallboard tiling cut out must fit very neatly around the square cover of flush panel No large gaps are permitted tolerance of approx 1mm 2 There may be significant amounts of dust when preparing the wall be sure to fit dust cover over cistern opening and protect the electrical fittings and pipework Fig 14 Bow...

Page 11: ... signal wire and power cord through the wall and under the tank F Bowl installation 1 Remove the side panels 2 Install the discharge pipe and water inlet pipe as shown Place a ruler on the rear of the discharge pipe and water inlet and use a pencil to mark the position Adjust the space based on the rear of the toilet to wall discharge port Concealed conduit Control panel signal wire Bidet water su...

Page 12: ...r supply hose straight end onto the water supply fitting on tank frame Feed hose under the pan connector discharge pipe and attach the MF fitting onto the 90º bend Attach this end to the pan inlet Ensure the pan fixing bolts are tight against the wall as shown Apply grease to the discharge port to ease installation CAUTION Toilet is heavy use a two person lift Discharge Pipe Water Inlet Pipe Big rubb...

Page 13: ...crews on the right hand side of the toilet and remove the side panel Remove the 3 remaining screws and remove the junction box cover 8 Feed the power cord through the rubber gasket from the wall and connect to the junction box NOTE Wiring order shall be L N Ground from top to bottom L Live wire N Neutral wire Grounding wire Fig 23 Fig 24 Power switch is OFF Green light OFF Valve is OFF Kohler Co J...

Page 14: ...witch to ON and open water inlet valve 12 Apply silicone sealant around the back edge of the pan to ensure a clean adhesion to the wall Install the left and right side panels Power switch is OFF Green light OFF Valve is ON In Wall tank water outlet hose Kohler Co Jan 2018 14 1345889 A02 A G Water Level adjustment 1 Follow the steps 6 to 11 on page 19 and 20 of this document to remove the water inl...

Page 15: ...ing lock H Control panel installation 1 Slide water splash plate into Slot A and B in square cover NOTE After the splash plate is installed the locators should be under the surface Fig 29 Snap in position Locators Slot A Square cover Slot B Water splash plate Fig 28 2 Turn the screw clockwise to increase the water level by 5mm Place the water inlet vavle in its original position ...

Page 16: ...assembly signal wire and control panel signal Wire into U type hole of splash plate as shown below Kohler Co Jan 2018 16 1345889 A02 A 3 Screw two lag bolts into the bracket as shown Ensure the bolts are perpendicular to the wall Fig 32 Supporting bracket Bolt Lag Bolt 2 Tighten the four screws to LOCK mark after installing the supporting board Fig 31 Supporting board Locknut ...

Page 17: ...r assembly signal wire 1 Dismantle the control panel as shown Hold control panel bottom with both hands and push upward to open the panel Ope from the bottom up Dismantle motor assembly signal wire and control panel signal wire Dismantle and service discharge valve Flush FULL button Flush ECO button Fig 34 5 Once connected to the power and water supply the toilet is ready for use ...

Page 18: ... A Snap in position Slot A Square cover Water splash plate Fig 39 Fig 38 Supporting board 4 Dismantle supporting board as shown Fig 37 Locknut Supporting board 3 Pay special attention when dismantling supporting board All 4 lock nuts should align with the OPEN mark ...

Page 19: ...racket 8 Take discharge valve lever out from lag washers on both ends as shown Bracket Fig 41 Fig 42 Lever clip Lag washer Kohler Co Jan 2018 19 1345889 A02 A 6 Dismantle motor assembly snap in mechanism remove motor assembly Fig 40 Snap in mechanism Motor assembly ...

Page 20: ...1345889 A02 A Water inlet valve Tighten Filter Loose 10 Loosen filter nut as shown 11 Remove the water inlet valve for cleaning or adjusting 9 Open close water supply Rotate valve switch to open close water supply as shown Fig 43 On Valve Off ...

Page 21: ...lve along the arrow direction as shown It should make a click sound when installing or removing 14 Loosen discharge valve as shown and then take valve out for cleaning or adjusting Fig 46 Fastener Fastener 12 Hold fastener by hand as shown pull the top of fastener along with the direction of arrow Then remove fastener ...

Page 22: ...ntrol pole will cause the water level to change within the water tank Turn the pole clockwise to increase the water level and anti clockwise to reduce it Kohler Co Jan 2018 22 1345889 A02 A Fig 51 Fig 50 Control Pole Inlet Valve Adjustment Switch Floating Box Drainage valve Floating Box Fig 49 Loosen Locknut Tighten Filtration Net Filter I Clean Filter Loosen filter locknut as shown Clean filter dir...

Page 23: ... 1 Select a proper position for the control docking station to be installed The position shall be easily operated by the user when seated on the toilet 2 Based on the docking station hole positions drill two 6mm diameter holes 45mm deep 3 Insert lag bolt anchors into the holes 4 Remove the double sided tape and place docking station over the fixing holes 5 Fasten docking station with screws and pl...

Page 24: ...at sensor is not detecting the user A Remove object or wipe seat working B Accidental pressing of STOP button B If needed sit on again after 2 seconds C Auto deodorising function is disabled C Refer to Remote setting guide section 9 Unable to open or A The seat sensor is not detecting the user A Remove object or wipe seat close cover B Customer interference during previous B Use the remote or manu...

Page 25: ...on section connect toilet to remote 15 Seat temp is low A Seat temp is OFF A Refer to Remote guide section when seated for temperature settings B Energy saving mode B Refer to Remote guide section to exit energy saving mode 16 No water supply A Water inlet valve is not OPEN A Open water inlet valve from inlet valve B Water inlet float is covered by other parts B Adjust other parts to avoid anycont...

Page 26: ...id the KOHLER warranty WARNING Do not use cement to install toilet The cement thermal expansion may cause toilet feet to be damaged and or burst KOHLER will not be responsible for any toilet damage caused by unsuitable installation products or methods WARNING Prevent toilet damage Do not toss unusual products into toilet which may cause clogging Do not apply impact forces to bowl as it may cause d...

Reviews: