background image

 

USER GUIDE 

 
 

 

KISS 4U V3 SKX 

Doc. Preliminary Rev. 0.6 

Doc. ID: 1065-2473 

 

 

Summary of Contents for KISS 4U V3

Page 1: ...USER GUIDE KISS 4U V3 SKX Doc Preliminary Rev 0 6 Doc ID 1065 2473...

Page 2: ...KISS 4U V3 SKX Preliminary Rev 0 6 www kontron com 2 This page has been intentionally left blank...

Page 3: ...ication will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and inst...

Page 4: ...USE OR RESALE FOR THE OPERATION OF APPLICATION IN A HAZARDOUS ENVIRONMENT OR REQUIRING FAIL SAFE PERFORMANCE OR IN WHICH THE FAILURE OF PRODUCTS COULD LEAD DIRECTLY TO DEATH PERSONAL INJURY OR SEVERE...

Page 5: ...Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths into a se...

Page 6: ...ts of them Failure to observe the precautions indicated and or prescribed by the law may endanger your life health and or result in damage to your material Please refer also to the High Voltage Safety...

Page 7: ...ges before performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be dis...

Page 8: ...necessary to store or ship the product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instr...

Page 9: ...duction 17 3 Scope of Delivery 18 3 1 Accessories and Spare Parts 18 3 2 Shipment Packaging and Unpacking 18 3 3 Type Label and Product Identification 18 4 Product Description 19 4 1 Front Side 21 4 1...

Page 10: ...ing System OS and Hardware Components Drivers 51 10 Maintenance and Prevention 52 10 1 Cleaning the Filter Pad 52 10 2 Replacing the Fan Assembly 54 10 3 Replacing the Lithium Battery 56 11 Technical...

Page 11: ...re 9 19 Handle Bracket 21 Figure 10 Front Side with Front Access Panel Opened 22 Figure 11 Front side Tower Variant with Front Access Panel Closed 22 Figure 12 Power Button 23 Figure 13 USB 2 0 Ports...

Page 12: ...Filter Pad Holder without Filter Pad 53 Figure 39 Filter Pad Holder with Filter Pad 53 Figure 40 Filter Pad 53 Figure 41 Removing the Fan Assembly 54 Figure 42 Fan Compartment without Fan Assembly 54...

Page 13: ...product To guarantee sufficient airflow to cool the product ensure that Ventilation openings are not covered or blocked Clean the filter pad regularly Do not place the system close to heat sources or...

Page 14: ...power Reliable protective earth connection is provided Suitable easily accessible disconnecting device is used in the application e g overcurrent protective device if the product cannot be disconnect...

Page 15: ...SD safe containers such as boxes or bags 2 Keep electrostatic sensitive parts in their containers until they arrive at the ESD safe workplace 3 Always be properly grounded when touching a sensitive bo...

Page 16: ...ery Danger of explosion when replacing with wrong type of battery Replace only with the same or equivalent type recommended by the manufacturer The lithium battery type must be UL recognized Do not di...

Page 17: ...ISS 4U V3 SKX is designed for high performance reliability and use in harsh Industrial environments offering total flexibility with installation options in a 19 industrial rack desktop or tower Genera...

Page 18: ...ructions for IT equipment Hold down clamp 1 Fastens to the expansion card bracket on one end and clamps on the expansion card using a notch of the free end height adjustable by shortening the free end...

Page 19: ...3 SKX platform s design enables installation in 19 industrial racks desktop or tower Figure 2 Rackmount Variant closed front access panel Figure 3 Tower Variant closed front access panel Figure 4 Desk...

Page 20: ...y system status and system ID LEDs Three system fans are installed at the front side of the system The three fans are part of interchangeable fan assembly The fan assembly simplifies the installation...

Page 21: ...mechanism 6 LED indicators 7 Front access panel side plate For use as a desktop system remove both handle brackets right side and left side see Chapter 8 2 Removing the Handle Brackets and attach the...

Page 22: ...ccess panel with air intake ventilation holes 3 Filter pad and filter pad holder with knurled screws 4 Securing lock mechanism two keys provided 5 D3 fixed front accessible slim drive bay 6 D2 shown w...

Page 23: ...ront panel power button or the PSU s power On Off switch may not disconnect the KISS 4U V3 SKX platform from the main power source A standby voltage of 5 VSB may remain The KISS 4V V3 SKX is only comp...

Page 24: ...D Button powers On Off the SYSID LED to identify the system in a multi system environment SYSF2 NC SYSF1 Red Indicates system status and signalizes if a signal failure occurs LED OFF system OK LED ON...

Page 25: ...lace a defective fan assemble only with Kontron s original fan assembly see Table 2 Accessories and Spares Parts Fan assembly replaceable during operation Replace fan only by qualified specialist or a...

Page 26: ...vable fixed or internal drives and may be used in combination to implement a three drive solution Front accessible drive option D1 1x 3 5 HDD or 2x 2 5 HDD SSD or 4x 2 5 HDD SSD D2 1x 3 5 HDD or 2x 2...

Page 27: ...on Figure 16 Rear Side 1 PSU power On Off switch 2 AC inlet connector 3 External mainboard interfaces see Chapter4 2 1 External Interface 4 7x PCIe 3 0 full height full length expansion slots 5 2x rea...

Page 28: ...only 4 2 1 1 PS 2 Port The PS 2 port is a combined keyboard or mouse port For the port s pin assignment see Chapter 12 1 PS 2 Keyboard Mouse Connector 4 2 1 2 USB BIOS Flashback Button The BIOS flash...

Page 29: ...ible devices For the port s pin assignment see Chapter 12 2 USB 2 0 Port 4 2 1 7 LAN Ports The dual LAN ports are IEEE1588 capable and enable the connection of Gigabit Ethernet 10 100 1000 Mb s device...

Page 30: ...tch may not disconnect the system from the main power source A standby voltage of 5 VSB may remain The KISS 4V V3 SKX is only completely disconnected from the main power source when the power cable is...

Page 31: ...e ventilation holes and can be removed to install a PCIe expansion card by releasing an internal screw at the top of the slot bracket Figure 19 PCIe Expansion Card Slot Numbering 1 Slot 1 2 Slot 2 3 S...

Page 32: ...he bottom side of the tower see Chapter 4 6 Bottom Side View Tower Variant Figure 20 Left Side View Figure 21 Right Side View 1 19 Handle bracket 2 6x M4 tapped holes for slide rails assembly on both...

Page 33: ...if the cover is attached and the cover s knurled screws are securely fastened Cover fastening screw Figure 10 pos 12 on the front side Two knurled screws Figure 16 pos 5 on the rear side The cover fa...

Page 34: ...cards 6 PSU 7 3x Serial ports openings optional 8 Mainboard interface panel 9 Expansion card slots 1 to slot 7 and fastening screw 10 Internal fastening screw short card hold down bracket 11 Internal...

Page 35: ...Chapter 8 1 Attaching the Rubber Feet in the positions shown in Figure 24 When the KISS 4U V3 SKX tower is upright the three system fans must be located in the lower part and the drive bays in the up...

Page 36: ...front accessible or a mix of front accessible and internal Table 4 Drive Bay Combinations Front Accessible Drive Bays Drive Bay Storage Device Capacity HDD SSD Type Description Bay1 1x 3 5 HDD 2 TB 4...

Page 37: ...e slot 7 Figure 19 pos 7 To improve graphical performance an optional GPU expansion cards can be implemented in the GPU default slot 3 Figure 19 pos 3 For information on Kontron reference GPU expansio...

Page 38: ...s Additionally each of the dual CPUs is equipped with an active cooler controlled by the mainboard The PSU is equipped with a fan to extract air directly at the rear of the system 6 2 Minimum System C...

Page 39: ...enance must be performed by qualified personnel aware of the associated dangers To open the cover proceed as follows 1 Switch off and disconnect the system from the mains power supply 2 If the front a...

Page 40: ...s shown in Figure 28 Figure 28 Removing the Cover 6 To close and secure the cover proceed in the reverse order step 5 to step 2 The KISS 4U V3 SKX is only properly closed when the cover is attached pr...

Page 41: ...afety instructions included in Chapter 1 General Safety Instructions for IT Equipment 7 2 1 Installing Removing Expansion Cards The expansion cards are secured using the front slot bracket Figure 23 p...

Page 42: ...g screw that secure the retaining bracket Figure 30 step 6 Lift the retaining bracket upwards Figure 30 step 7 to remove Retain the retaining bracket and two screws for later use 6 Loosen the internal...

Page 43: ...s firmly and the retaining bracket Only then tighten the internal screws at the notches that secure the card hold down brackets 9 Close the KISS 4U V3 SKX platform and secure the cover with the captiv...

Page 44: ...on cards before installing the KISS 4U V3 SKX 8 1 Attaching the Rubber Feet Attach the supplied four rubber feet to the KISS 4U V3 SKX platform to avoid scratching the user environment s surface For t...

Page 45: ...front access panel and front access side plates proceed as follows 1 Remove the handle brackets as described in Chapter 8 2 Removing the Handle Brackets steps 1 2 and retain the handle bracket and sc...

Page 46: ...the Rubber Feet 2 If required remove the handle brackets as described in Chapter 8 2 Removing the Handle Brackets 3 If required remove the front access panel and two front access panel side plates as...

Page 47: ...holes Figure 9 pos 3 5 Verify that the KISS 4U V3 SKX is securely mounted 8 6 Installing Slide Rails Option Kontron offers compatible 19 Slide Rails and Rack Slide Rails Kit for the KISS 4U V3 SKX For...

Page 48: ...Figure 33 Slide Rail in the Pulled out Position Figure 34 Slide Rail in the Pushed in Position 1 Side view of the KISS 4U V3 SKX 2 6x M4 rounded head screws per side 3 Inner part of the slide rail 4 L...

Page 49: ...ckets 2 Add the four rubber feet to the left side of system as described in Chapter 8 1 Attaching the Rubber Feet Attach the four rubber feet close to the four corners of the underside of the tower to...

Page 50: ...pletely disconnected from the main power source when the power cable is disconnected either from the mains power plug socket or the PSU s AC power cable connector Therefore for safety reasons the powe...

Page 51: ...e the system uses the last state before the AC power loss 9 2 Operating System OS and Hardware Components Drivers The KISS 4U V3 SKX is operational when switched on for the first time with a pre insta...

Page 52: ...e changed during operation Figure 36 Filter Pad Holder on the Front Side 1 Filter pad 2 Filter pad holder s knurled screws 3 Filter pad holder 4 Fan assembly with two knurled screws To replace the fil...

Page 53: ...e fan assembly Defective components may only be replaced by Kontron original spare parts For a list of spare parts see Table 2 Accessories and Spares Parts Figure 37 Fan Assembly without Filter Pad Ho...

Page 54: ...No tools required Key is required if the front access panel has been locked The filter pad holder can be fasten to the front side of the fan assembly either before or after the fan assembly is install...

Page 55: ...mbly housing 7 Reverse side of Figure 43 pos 1 Knurled screws 5 Replace the fan assembly with a new functional module 6 Insert the fan assembly s positioning plate Figure 43 pos 5 behind the fan compa...

Page 56: ...hium battery CR2032 on the mainboard proceed as follows 1 Switch off and disconnect the system from the mains power supply 2 Open the cover as described in the Chapter 7 1 Opening and Closing the Cove...

Page 57: ...KISS 4U V3 SKX Preliminary Rev 0 6 www kontron com 57 11 Technical Data 11 1 Block Diagram Figure 45 Block Diagram KISS4U V3 SKX...

Page 58: ...rt supports USB BIOS Flashback 4x USB 3 1 Gen1 1x USB 3 1 Gen2 Type A 1x USB 3 1 Gen2 Type C LAN 2x 1 Gb Intel I210 AT controllers 2x 1 Gb Intel i210 AT controllers With support share LAN failover LAN...

Page 59: ...256 GB to 1TB SSD removable 4x 2 5 HDD SSD 1TB HDD 256 GB to 1TB SSD removable Drive Bay 3 1x DVD fixed RW slimline Internal Drive Options Drive Bay 1 1x 3 5 HDD 2 TB 4 TB 6 TB fixed Drive Bay 2 1x 3...

Page 60: ...pecification Table 8 Environmental Specification Temperature Description Temperature operating 0 C 45 C 32 F 113 F Temperature storage 20 C 70 C 4 F 158 F Humidity Operating Storage 40 C 93 non conden...

Page 61: ...omagnetic Compatibility EMC Directive 2014 30 EU Restriction of Hazardous Substance Directive RoHS II 2011 65 EU Waste Electrical and Electronic Equipment Directive WEEE 2012 19 EU Electrical Safety E...

Page 62: ...Data 2 N C 3 GND 4 5 V 5 Keyboard Mouse Clock 6 N C 12 2 USB 2 0 Port Pin Signal Name 4 pin USB 2 0 Type A 1 VCC 2 Data 3 Data 4 GND 12 3 USB 3 1 Gen 1 and USB 3 1 Gen 2 Type A Port Pin Signal Name Pi...

Page 63: ...s data storage only USB 3 1 Gen 1 and USB 3 1 Gen 2 data transfer rates differ For optimum performance use USB devices that match the USB ports transfer rate 12 5 Ethernet Connector Ethernet Port LED...

Page 64: ...hannel 4 Channel 5 1 channel 7 1 channel Light Blue Line in Line in Line in Side Speaker Out Green Line out Front Speaker out Front speaker Out Front Speaker Out Pink Mic In Mic In Mic In Mic In Orang...

Page 65: ...tings for control or modification of the uEFI BIOS configuration The Setup program allows for access to various menus that provide functions or access to sub menus with further specific functions of t...

Page 66: ...13 2 BIOS Update To ensure compatibility with new operating systems OS hardware or software and to integrate new BIOS functions Kontron recommends updating the BIOS To update the BIOS easily use the...

Page 67: ...D blinks three times to indicate a successful BIOS update and wait until BIOS update is completed and the light goes out Do not switch off or interrupt the system during a BIOS update If interrupted t...

Page 68: ...repaired or replaced within the stipulated warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website RMA website http www kontron com support and...

Page 69: ...ered to avoid damage The storage facility must meet the products environmental storage requirements as stated within this user guide Kontron recommends keeping the original packaging material for futu...

Page 70: ...o honor the warranty even during the warranty period and shall be exempted from the statutory accident liability obligations in the event of damage caused to the product due to failure to observe the...

Page 71: ...Area Network LED Light Emitting Diode LVD Low Voltage Directive MEI Management Engine Interface NCSI Network Communications Services Interface NRTL Nationally Recognized Test Laboratory OS Operating...

Page 72: ...made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accele...

Reviews: