background image

GLD060-0-0803

Vent-Free Gas Log Heater

MODEL:  GLD1850

                GLD2440

                GLD2450

Questions  about  installation,  operation,  or  troubleshooting?

  Before  returning  to  your  retailer,  call  

the 

KOZY WORLD PHONE NUMBER (814)643-1775

.

 

CAUTION - FOR YOUR SAFETY

  

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED   

       EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY  
       DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

--

    

Do not store or use gasoline or other flammable vapors and liquids in vicinity   

     of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do not use any phone in your building.

 

Immediately call your gas supplier from a neighbor’s phone. Follow the  

            gas supplier’s instructions.

 

If you cannot reach your gas supplier, call the fire department.

--   Installation and service must be performed by a qualified installer, service     

     agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which   

it is installed. Provisions for adequate combustion and ventilation air must be 

provided. Refer to Air For Combustion and Ventilation section on page 5 of this 

manual.

INSTALLER: DO NO DISCARD THIS MANUAL – LEAVE FOR HOMEOWNER’S 

FUTURE REFERENCE

This appliance may be installed in an aftermarket, permanently located, 

manufactured  (mobile)  home,  where  not  prohibited  by  local  codes.  This 

appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

WARNING: 

This appliance is equipped

for (Natural and Propane) gas. Field
conversion is not permitted other than
between natural or propane gases.

  

Kozy-World

 

®

 

 

Summary of Contents for GLD1850

Page 1: ...tructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas...

Page 2: ...before starting installation Failure to fol low these instructions may result in a possible fire hazard and will void the warranty ITEM NO GLD2440 GLD2450 Input Rating 32 000BTU Hr 32 000BTU Hr Gas Ty...

Page 3: ...heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Natural and Propane LP Gas Natural or propane LP gas is odorless An odor producing agent is added to n...

Page 4: ...om you must open the vents before operating log set Always operate heater with glass doors fully open 8 This log heater is designed to be smokeless If logs ever appear to be smoking turn off heater an...

Page 5: ...nd fuel burning appliances draw air from the house To operate you must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PRODUCING ADEQU...

Page 6: ...adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air From Outdoors page 7 Ve...

Page 7: ...ETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there...

Page 8: ...nspect chimney flue for damage WARNING Maintain the minimum clearances If possible provide greater clearances from the floor ceiling and adjoining wall than required Minimum Fireplace Clearance to Com...

Page 9: ...E This heater is intended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source If you have a central heating sys t...

Page 10: ...requirements IMPORTANT If these minimum clear ances are not met you must operate heater with chimney flue damper open Go to Installing Damper Clamp Accessory for Vented Operation page 11 MANTEL CLEARA...

Page 11: ...e three reasons for operating your heater as a vented model 1 The fireplace does not meet the clearance requirements for vent free operation 2 State or local codes do not permit vent free operation 3...

Page 12: ...ove when you adjust controls Moving heater may cause a gas leak WARNING If installing in a sunken fireplace special care is needed You must raise the fireplace floor to allow access to heater control...

Page 13: ...re 14 To pre vent performance problems Propane LP tank of less than 100 lbs capacity is not recommended IMPORTANT Install an equipment shutoff valve in an accessible location The equipment shutoff val...

Page 14: ...d in the NG position Do not operate heater between locked positions 3 Remove hex plug with wrench provided from natural gas inlet of regulator and install into LP inlet of regulator use thread sealant...

Page 15: ...soap and water to gas joints Bubbles forming indicate a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pres...

Page 16: ...is very important to install these logs exactly as instructed Do not modify logs After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs or burne...

Page 17: ...ry important to install these logs exactly as instructed Do not modify logs After installing logs add decorative cinders around the grate base do not place any decorative cinders on logs or burner 1 I...

Page 18: ...ors fully open FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life When...

Page 19: ...ian or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Turn gas control knob clockwise to OFF position Do not force 2 If applicable Turn off all electric power to the appliance MATCH LIGHTING INSTRUCTIONS...

Page 20: ...g the thermocouple This will cause he thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 35 Turn heater off see To Turn O...

Page 21: ...e unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 38 3 Blow air through the ports slots and holes in the bur...

Page 22: ...ntrol knob while pressing ignitor button 3 Continue holding down control knob Repeat igniting operation until air is removed 4 Clean ODS pilot see Care and Maintenance page 21 or replace ODS pilot ass...

Page 23: ...on 1 Residues from manufactory 2 Not enough combustion ventila tion air 1 Problem will stop after a few hours 2 Refer to air for combustion and venti lation requirements 1 Control knob not fully press...

Page 24: ...nections page15 2 Replace control valve 1 Gas leak See Warning statement page 21 2 Control valve defective Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See W...

Page 25: ...KOZY WORLD PHONE NUMBER 814 643 1775 When contacting your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used natural or pro...

Page 26: ...26 26 This list contains replaceable parts for your heater When ordering replacement parts follow the instructions listed under Replacement Parts on page 25 of this manual GLD1850 GLD2450...

Page 27: ...27 27...

Page 28: ...28 28 This list contains replaceable parts for your heater When ordering replacement parts follow the instructions listed under Replacement Parts on page 25 of this manual GLD2440...

Page 29: ...29 29 Printed in China...