Wireless Full Bin Alarm 

Installation and Operating Manual  
 

The Wireless Full Bin Alarm is designed 
to provide the ultimate in convenience 
and safety to perform tasks remotely. 
It is a radio frequency (RF) sensing 
device that helps prevent overfilling of 
grain bins by activating an alarm when 
the grain Sensor Probe is activated. 
The Sensor Probe, which operates at 

915.8 MHz FM, transmits securely encoded information to the Receiver, which 
then decodes the information and alerts the user that the bin is full. The Sensor 
Probe and Receiver are designed to operate within 300' but actual range is 
dependent on operating environment. 
 

 
 

 

Summary of Contents for XLOR Series

Page 1: ...vice that helps prevent overfilling of grain bins by activating an alarm when the grain Sensor Probe is activated The Sensor Probe which operates at 915 8 MHz FM transmits securely encoded information to the Receiver which then decodes the information and alerts the user that the bin is full The Sensor Probe and Receiver are designed to operate within 300 but actual range is dependent on operating...

Page 2: ...f Contents Table of Contents Table of Contents Table of Contents Specifications 1 FCC 2 Industry Canada 2 Overview 3 Mechanical Installation 4 Receiver Console 4 Sensor Probe 4 Electrical Installation 4 Receiver Console 4 Sensor Probe 5 Antenna Mounting 5 General Operation 5 Receiver Console 5 Sensor Probe 7 Sensor Self Test 8 Sensor Angle Setup 8 Limited Warranty 9 Table of Figures Table of Figur...

Page 3: ...ators Internal System Battery Test Case Size 3 dia x 13 long Range 300 depending on environment Antenna External 3 15 Flexible Tuned Security Code Preprogrammed Unique Identifier Environment Weatherproof Receiver Power in 12 VDC Standby Current 40mA Alarm Current 200mA Case Size 8 x 4 8 x 2 5 Power Input 15 16ga 2 conductor wire with plug and lock connectors Indicators Power On Red LED Transmitter...

Page 4: ... equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Indust...

Page 5: ...cates when the grain level in the bin is reaching its maximum The system consists of a Receiver Console with audible and visible alarms a Sensor Probe that hangs into the grain bin suspended from the spout of an auger and an antenna that connects to the sensor probe and is mounted at the top of the auger The battery powered Sensor Probe is fully sealed and communicates wirelessly via radio frequen...

Page 6: ...ng kit contains a 12 chain a U bolt two strap plates four hex nuts four flat washers and two quick link connectors Drill two holes 1 3 8 apart in the spout and attach the U bolt as shown in the following figure Use a quick link to attach the chain to the U bolt and the second quick link to attach the chain to the Sensor Probe The U bolt may be mounted on the inside of the spout if space is limited...

Page 7: ... receiver Do not point the antenna at the receiver reception will be better when the antenna s side faces the receiver General Operation General Operation General Operation General Operation Receiver Console Receiver Console Receiver Console Receiver Console The Receiver Console is powered by 12 volts DC and is equipped with a Power On Off button and a Cancel Alarm CAN button on the front of the c...

Page 8: ...e Sensor Probe battery needs to be replaced Once activated the green LED will remain on until the receiver is powered off FBA Receiver Console Self Test To test the Receiver Console alarm light and siren hold the cancel button for six seconds while the Full Bin Alarm is powered on Once tested the alarm will shut off when the cancel button is released The Receiver power may be turned off when not i...

Page 9: ...rd Factory default systems are set by default so that the Learn function is Enabled and the Erase function is Disabled Figure 3 Learn Erase Function Sensor Probe Sensor Probe Sensor Probe Sensor Probe The Sensor Probe is powered by one 9v battery If the battery voltage falls below 7 volts the transmitter will transmit a Low Battery signal approximately once per hour which will illuminate the green...

Page 10: ...he threshold To exit test mode hold the button again until the yellow LED remains off The Full Bin Alarm Sensor Probe will not transmit a signal while in test mode Ensure that the LEDs are not lit before reassembling the sensor Up to eight Sensor Probes can communicate to the same Receiver Console as long as the Receiver Console has learned the probes security codes Sensor Angle Setup Sensor Angle...

Page 11: ...mental policy at Kramble Industries Inc All customers can rely upon and expect to receive prompt efficient and courteous service on all Kramble Industries Inc manufactured equipment from each and every employee of the organization Kramble Industries Inc with its office at 102 2750 Faithfull Avenue Saskatoon SK warrants To the Original Purchaser User each product manufactured by Kramble Industries ...

Page 12: ...per installation re designing of assemblies ignorance or through any other cause beyond the control of the company 3 The warranty does not cover products of other manufacturers beyond such warranty as may be made by such manufacturer 4 The warranty shall not apply to normal maintenance services or to deterioration of appearance of items due to normal use and exposure 5 The warranty shall not apply...