KSI2300002.300
INSTALLATION AND PROGRAMMATION MANUAL
WIRELESS MODULE 2 INPUTS / 2 OUTPUTS
868 MHZ BIDIRECTIONAL
INDEX
INTRODUCTION
TECHNICAL DATA
auxi wls
is a wireless module with 2 built-in inputs and outputs. Powered directly from the mains,
auxi wls
is ideal to remotely manage lights, home
automations (
such as roller blinds and curtains
) and, generally, any load unreachable by cables.
auxi wls
can be used in conjunction with
lares
Control Panels or as a stand-alone device. In the second case, the outputs can be controlled locally (
using the inputs on board
) or remotely, using
the
opera
remote control. Up to 32 different remote controls can be enrolled for each
auxi wls
.
• Voltage ................................................................................................................................................................................................... 110 -230 VAC 50-60Hz
• Frequency .......................................................................................................................................................................................................................868 MHz
• Operative range in open air .........................................................................................................................................................................up to 150 meters
• Inputs ...........................................................................................................................................................................................................................................2
• Outputs......................................................................................................................................................................................... 2 (5A 250V~AC - 5A 30VDC)
• Operative range ......................................................................................................................................................................................................-20 / + 55°C
• Dimensions ........................................................................................................................................................................................42 x 35 x 20 mm (s x h x d)
• Protection class .....................................................................................................................................................................................................................IP20
Technical specifications, appearance, functionally and other product charateristics may change without notice.
1
2
5
3
6
4
7
A
1
2
3
4
6
7
5
B
C
D
PARTS IDENTIFICATION | TERMINALS | WIRING EXAMPLES
Input 1
Input 2
Common relay contacts
Power supply - neutral
Relay output 1
Power supply - phase
Relay output 2
A
B
C
D
E
Terminal blocks
Programmation button
Signalisation LED
Serial Number Label
Radio Antenna
DO NOT CUT
INPUTS SUPPLY
OUTPUTS
i1
i2
N
L
C
o1
o2
110-230 VAC
50-60 HZ
1
2
3
4
5
6
7
L
N
Resistive
Load
INPUTS SUPPLY
OUTPUTS
i1
i2
N
L
C
o1
o2
110-230 VAC
50-60 HZ
1
2
3
4
5
6
7
L
N