TECHNICAL DATA

auxi wls

 is a wireless module with 2 built-in inputs and outputs. Powered directly from the mains, 

auxi wls

 is ideal to remotely manage lights, home 

automations (

such as roller blinds and curtains

) and, generally, any load unreachable by cables. 

auxi wls

 can be used in conjunction with 

lares

 

Control Panels or as a stand-alone device. In the second case, the outputs can be controlled locally (

using the inputs on board

) or remotely, using 

the 

opera

 remote control. Up to 32 different remote controls can be enrolled for each 

auxi wls

.

• Voltage ................................................................................................................................................................................................... 110 -230 VAC 50-60Hz

• Frequency .......................................................................................................................................................................................................................868 MHz

• Operative range in open air .........................................................................................................................................................................up to 150 meters

• Inputs ...........................................................................................................................................................................................................................................2

• Outputs......................................................................................................................................................................................... 2 (5A 250V~AC - 5A 30VDC)

• Operative range ......................................................................................................................................................................................................-20 / + 55°C

• Dimensions ........................................................................................................................................................................................42 x 35 x 20 mm (s x h x d)

• Protection class .....................................................................................................................................................................................................................IP20

Technical specifications, appearance, functionally and other product charateristics may change without notice.

1

2

5

3

6

4

7

A

1

2

3

4

6

7

5

B

C

D

PARTS IDENTIFICATION | TERMINALS | WIRING EXAMPLES

Input 1
Input 2

Common relay contacts

Power supply - neutral

Relay output 1

Power supply - phase

Relay output 2

A

B

C

D

E

Terminal blocks
Programmation button
Signalisation LED
Serial Number Label
Radio Antenna 

DO NOT CUT

INPUTS SUPPLY

OUTPUTS

i1

i2

N

L

C

o1

o2

110-230 VAC

50-60 HZ

1

2

3

4

5

6

7

L

N

Resistive
Load

INPUTS SUPPLY

OUTPUTS

i1

i2

N

L

C

o1

o2

110-230 VAC

50-60 HZ

1

2

3

4

5

6

7

L

N

INTRODUCTION ............................................................................................................................................................................................................................ 1

TECHNICAL DATA ........................................................................................................................................................................................................................ 1

PARTS IDENTIFI TERMINALS ......................................................................................................................................................................................... 1

WIRING EXAMPLES ...................................................................................................................................................................................................................... 1

OUTPUTS MANAGEMENT THROUGH LOCAL CONTACTS (STAND-ALONE | LARES) ................................................................................................................. 2

OUTPUTS WORKING MODES........................................................................................................................................................................................................ 2

FUNCTIONS .................................................................................................................................................................................................................................. 2

OUTPUT MANAGEMENT THROUGH OPERA REMOTE COMMANDS (STAND-ALONE) ............................................................................................................... 3

OUTPUT MANAGEMENT THROUGH PANEL SCENARIOS ............................................................................................................................................................. 3

PROGRAMMATION OF RADIO MODULE USING LARES CONTROL PANEL ................................................................................................................................ 4

PROGRAMMATION OF RADIO MODULE AS STAND-ALONE DEVICE ........................................................................................................................................ 4

PROGRAMMATION...................................................................................................................................................................................................................... 4

LED FUNCTIONS ........................................................................................................................................................................................................................... 4

FACTORY DATA RESTORAL .......................................................................................................................................................................................................... 5

CERTIFICATIONS .......................................................................................................................................................................................................................... 5

Reviews: