The menu button accesses the following settings or modes:
ProLaser 4 Quick Reference Guide
RCMP Configuration
Head-Up Display
6
ProLaser 4 Menus
Distance
Sets min/max range limits to target vehicle for school
and work zone enforcement. Fire the LASER at the
desired target or use up/down arrows to enter values.
Press enter to set min/max ranges. Any target measured
outside the range limits will not be displayed.
Set Direction
Sets target direction discrimination to Approaching
only, Receding only, or Both.
DIF-TEST
Two-target, differential distance accuracy test mode.
Continuous/
Single
Sets enforcement mode to continuous target
measurement or single shot mode (option).
Units
Select between mph/km/h; mph/knots; or km/h/knots (option).
HUD
Options
Toggle Range in HUD on/off. Select from four aiming
reticles.
Events
Displays last 100 locked targets with Speed, Range
and Direction with date and time stamp.
Set
Time/Date
Set date and time in 24 hour format (option).
Stopwatch
Average speed over distance enforcement mode (option).
Self-Test
Press the test button to run internal accuracy tests.
HUD Alignment
Test
Place the ProLaser 4 in range mode. Select an isolated
target ~100 feet away and sweep HUD horizontally and
vertically across target. Listen for audio tone and verify
aiming reticle on target coincides with tone and range
measurement in HUD.
Differential
Distance Test
Select two targets ~ 50 and 100 feet away. Target each
when prompted and verify range accuracy.
KSI p/n 006-0966-12 Rev 3
(800)4KUSTOM
(800) 458-7866
www.kustomsignals.com