background image

SYVA

rigging manual (EN)

Summary of Contents for Syva

Page 1: ...SYVA rigging manual EN...

Page 2: ...manual EN version 1 1 Distribution date June 8 2017 2017 L Acoustics All rights reserved No part of this publication may be reproduced or transmitted in any form or by any means without the express w...

Page 3: ...procedures 18 Wall mounting Syva 18 Flying Syva 22 Pole mounting Syva 23 Stacking Syva on Syva Low 24 APPENDIX A Mounting a truss clamp on Syva Wall 25 APPENDIX B Storing Syva Low Syva Sub in SyvaLF...

Page 4: ...h the safety precautions recommended by L Acoustics model the system in Soundvision and refer to the warnings in Mechanical Data section Be cautious when ying a loudspeaker con guration Always verify...

Page 5: ...rranty Symbols The following symbols are used in this document This symbol indicates a potential risk of harm to an individual or damage to the product It can also notify the user about instructions t...

Page 6: ...ly As part of a continuous evolution of techniques and standards L Acoustics reserves the right to change the speci cations of its products and the content of its document without prior notice Please...

Page 7: ...e Baseplate for Syva system Syva Pole Pole mount adapter for Syva Syva Bar Rigging bar for Syva Syva Cov Protective cover for Syva enclosure SyvaLF Cov Protective cover for Syva Low or Syva Sub enclos...

Page 8: ...System components Rigging elements Syva Wall Syva Base Syva Pole Syva Bar CLAMP250 Syva Cov SyvaLF Cov Syva rigging manual EN version 1 1 8...

Page 9: ...ety factor can be compliant with the 2006 42 EC Machinery Directive when the other deployment parameters provide the best mechanical conditions Syva Con guration Rigging accessory Maximum Safe limit F...

Page 10: ...n Assessing the safety with Soundvision The overall safety factor of a speci c mechanical con guration always corresponds to the lowest safety factor among all the linking points Always model the syst...

Page 11: ...d rigging accessories At the top an M8 insert can be tted with a DIN 580 eye bolt to implement a secondary safety safety point M8 linking points Syva can be stacked on top of Syva Low Four magnets and...

Page 12: ...te conceal and protect the rigging elements and connectors when they are not in use T30 3 N m T25 3 N m Always put the bottom plate screws back in place to avoid leaks Remove the bottom plate to stack...

Page 13: ...ow and Syva Sub Two anti vibration mats are provided to ground stack the subwoofers Syva Low features four studs on top to ensure stability when stacking Syva A top plate conceals them T25 3 N m 13 Sy...

Page 14: ...The bracket is secured to the enclosure It features a toothed wheel to set the azimut angle up to 90 by steps of 15 A safety pin secures the assembly base bracket wall mount linking points angle selec...

Page 15: ...or stability These can be removed to secure the base plate to the oor Risk of crushing injury Always hold Syva Base by the handle Ground stacking Syva Do not ground stack Syva without Syva Base Syva P...

Page 16: ...bar for Syva linking points Seven pickup points provide site angle settings between 10 and 5 5 2 0 2 5 7 5 10 Syva Bar and Syva can be own with the provided 12 mm shackle WLL 1 t or secured to a stru...

Page 17: ...sure protection plates storage shoulder strap handle fins top SyvaLF Cov is the reference cover for Syva Low and Syva Sub The front face with the logo is reinforced to protect the grill A ap covers th...

Page 18: ...perators 1 Secondary safety Secure a DIN 580 eye bolt to the dedicated insert on the enclosure to implement a secondary safety The speakON connector is only accessible if Syva Wall is used with a wedg...

Page 19: ...e to allow an azimut angle Azimut angle 15 30 45 60 75 90 Wedge depth 16 mm 0 6 in 32 mm 1 2 in 45 mm 1 8 in 55 mm 2 2 in 70 mm 2 8 in 80 mm 3 1 in 120 mm 4 7 in 6 mm 0 2 in 16 80 mm 0 6 3 1 in 201 mm...

Page 20: ...Rigging procedures 4 Secure the Syva Wall bracket to the enclosure T30 5 N m 5 Install the enclosure on the base and secure the safety pin CLICK Syva rigging manual EN version 1 1 20...

Page 21: ...the safety pin before changing the azimuth angle with Syva Wall Do not touch Syva Wall while changing the azimuth angle 6 Lift the enclosure by the bottom and rotate it to change the azimuth angle 90...

Page 22: ...ety Secure a DIN 580 eye bolt to the dedicated insert on the enclosure to implement a secondary safety Access to the screw terminal is limited after rigging Prepare the cabling before rigging the syst...

Page 23: ...nsion T30 Torx bit 17 mm wrench additional material 35 mm pole mount min number of operators 1 Procedure 1 Remove the backplate from Syva and secure Syva Pole on Syva Store plates and unused screws in...

Page 24: ...t additional material 4 x 6 mm 0 2 in screws depending on oor material optional min number of operators 1 Procedure Risk of crushing injury Always hold Syva Base by the handle Secure Syva Base on the...

Page 25: ...bolt with thread locking device or sealant min number of operators 1 About this task Syva Wall can be tted with a truss clamp to mount Syva on a truss bridge Exploded view Follow the clamp manufactur...

Page 26: ...Sub in SyvaLF Cov Procedure 1 Put the cover on the upright subwoofer with the logo on the front 2 Tilt the subwoofer to the side using the handles 3 Tilt the subwoofer upside down and close the zipper...

Page 27: ...8 Connectors IN 4 point speakON and screw terminal AutoConnect Rigging and handling DIN580 compatible M8 threaded insert for secondary safety 2 integrated inserts for rigging accessory Weight net 21...

Page 28: ...Speci cations Syva dimensions 144 mm 5 7 in 1301 mm 51 2 in 170 mm 6 7 in 209 mm 8 2 in 1304 mm 51 3 in Syva rigging manual EN version 1 1 28...

Page 29: ...W SYVA Maximum SPL 1 142 dB SYVA LOW SYVA Connectors IN 4 point speakON Weight net 50 kg 110 lb 1 Peak level at 1 m under half space conditions using pink noise with crest factor 4 preset speci ed in...

Page 30: ...nt speakON AutoConnect Weight net 29 kg 64 lb Cabinet rst grade Baltic beech and birch plywood Front steel grill with anti corrosion coating acoustically neutral 3D fabric Finish ne grain dark grey br...

Page 31: ...speakON AutoConnect Weight net 27 kg 60 lb Cabinet rst grade Baltic beech and birch plywood Front steel grill with anti corrosion coating acoustically neutral 3D fabric Finish ne grain dark grey brow...

Page 32: ...g 1 6 lb Material high grade steel with anti corrosion coating Syva Wall dimensions 41 mm 1 6 in 51 mm 2 in 74 mm 2 9 in 38 mm 1 5 in 224 mm 8 8 in 201 mm 7 9 in 35 mm 1 4 in 32 mm 1 3 in 65 mm 2 6 in...

Page 33: ...ription Baseplate for Syva system Weight net 11 kg 24 lb Material high grade steel with anti corrosion coating Syva Base dimensions 490 mm 19 3 in 18 5 mm 0 7 in 530 mm 20 9 in 7 mm 0 3 in x4 5 mm 0 2...

Page 34: ...on Pole mount adapter for Syva Weight net 0 8 kg 1 8 lb Material high grade steel with anti corrosion coating Syva Pole dimensions 124 mm 4 9 in 48 mm 1 9 in 38 mm 1 5 in 36 mm 1 4 in 100 mm 3 9 in 18...

Page 35: ...mm shackle WLL 1 t Weight net 1 3 kg 2 9 lb Material high grade steel with anti corrosion coating Syva Bar dimensions 13 mm 0 5 in x7 208 mm 8 2 in 30 mm 1 2 in 339 mm 13 3 in 75 mm 3 in 38 mm 1 5 in...

Page 36: ...m www l acoustics com L Acoustics GmbH Steierm rker Str 3 5 70469 Stuttgart Germany 49 7 11 89660 323 L Acoustics Ltd PO Box Adler Shine Aston House Cornwall Avenue London N3 1LF United Kingdom 44 722...