background image

WS-7034TWC 

Wireless 433 MHz 

Temperature Station

 

 

 

 

Instruction Manual 

 
 

 

 
 
 
 
 
 
 
 
 

 

Summary of Contents for WS-7034TWC

Page 1: ...WS 7034TWC Wireless 433 MHz Temperature Station Instruction Manual...

Page 2: ...Setting the Time 9 10 Selecting Units of Measurement 10 Features Minimum and Maximum Temperatures 11 Resetting Minimum and Maximum Temperatures 12 Adding additional remote temperature sensors optiona...

Page 3: ...remote temperature sensor 3 to 5 feet apart 2 Batteries should be out of both units for 10 minutes 3 Place the batteries into the remote temperature sensor first then into the indoor temperature stati...

Page 4: ...ase retry the set up as stated above After both indoor and outdoor temperatures are displayed for 10 minutes you can place your remote temperature sensor outdoors and set your time The remote temperat...

Page 5: ...exceed 80 ft in a straight line NOTE Fog and mist will not harm your remote temperature sensor but direct rain must be avoided To complete the set up of your indoor temperature station after the 10 m...

Page 6: ...r temperature station Figure 1 2 The remote temperature sensor TX6U and mounting bracket Figure 2 3 3 each 1 2 Philips screws 4 One strip of double sided adhesive tape 5 Instruction Manual and Warrant...

Page 7: ...7 DDITIONAL EQUIPMENT crewdriver batteries A not included 1 1 Philips s 2 2 Fresh AAA Alkaline 3 2 Fresh AA Alkaline batteries...

Page 8: ...on e ure cur 2 ure ns B 1 Install 2 AA batteries in th remote temperat sensor Make sure they do not spring free or start up problems may oc Install 2 AAA batteries in the indoor temperat station Do no...

Page 9: ...ill appear in the TIME LCD Press and releas button to select either 12h time am pm or 24h time Press and release the times the hour will flash in the upper left corner Press and re button to set the h...

Page 10: ...f Measurement 1 Press and hold the SET button for 5 second until 12h or 24h appears in the TIME LCD 2 Press and release the SET button again F will appear in the TIME LCD 3 Press and release the MIN M...

Page 11: ...minimum outdoor temperature will also flash 3 Press the MIN MAX button MAX appears next to the indoor and remote temperatures 4 The recorded maximum temperature is displayed The time of the maximum o...

Page 12: ...12 Resetting Min and Max Temperatures To reset both the minimum and maximum temperatures press and hold the RESET button for 4 seconds...

Page 13: ...hased through the same dealer as this unit or by contacting La Crosse Technology directly A TX6U will monitor temperature only a TX3U will monitor temperature and display the temperature on its LCD an...

Page 14: ...for ten minutes Transmission problems will arise if this is not done correctly To view the temperature of a different remote temperature sensor unit press and release the SET CH button A shift from on...

Page 15: ...80ft obstacles such as walls concrete and large metal objects will reduce the range Place both units in their desired location before permanently mounting Remote Temperature Sensor 1 Remove the mount...

Page 16: ...is required is to place the indoor temperature station in an appropriate location 1 To wall mount the indoor temperature station first remove the table stand 2 Next insert an appropriate screw in your...

Page 17: ...ion 1 Remove all batteries reinsert into remote temperature sensor first then into the indoor temperature station 2 Place remote temperature sensor closer to the indoor temperature station 3 Be sure a...

Page 18: ...the shielding effect of the display s case In addition the case can act as a heat sink to absorb and store heat from external sources i e handling of the case or radiant heat Also the much greater ran...

Page 19: ...t use solvents or scouring agents they may mark the displays and casings Do not submerge in water Do not subject the units to unnecessary heat or cold by placing them in the oven or freezer Opening th...

Page 20: ...e Sensor 21 8 F to 156 2 F with 0 2 F resolution 29 9 C to 69 0 C with 0 1 C resolution Temp accuracy 1 F 5 C Transmitting range Maximum 80 feet 25m open space Temperature check Indoor Every 10 second...

Page 21: ...6 x 88 x 5 90 in excluding table stand 60 x 22 5 x 150 mm Remote Temperature Sensor 1 57 x 0 85 x 5 00 in Battery life Approximately 1 year WARRANTY INFORMATION La Crosse Technology provides a 1 year...

Page 22: ...erature stations inability to receive a signal due to any source of interference LA CROSSE TECHNOLOGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATE...

Page 23: ...a Crescent MN 55947 Phone 507 895 7095 Fax 507 895 8000 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other products Website www lacrossetechnology co...

Page 24: ...OMO 01TX transmitter THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST AC...

Page 25: ...This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or pr...

Reviews: