(P/N) 735.028 Rev F • 02/10
© copyright 2006-2010
Kaba Mas LLC
STANDARD FEATURES
Manager Mode
• Open Lock
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
User Combination
• Open Lock
• Change Combination
Wrong Try Penalty
• Four (4) consecutive invalid combinations initiates five minute delay period.
Low Battery Warning
• Repeated audio and visual signal (LED flashing and repeated beeping) during opening indicates
battery low.
Audio and Visual Signal
• Double signal (LED flashes and unit beeps) indicates entry is valid or accepted.
• Triple signal indicates invalid or not accepted.
Audit Trail
• On-board non-volatile memory records up to 63 last events, including user ID and action.
PRogRAMMABLE FEATURES
ACTiVE
Combination length
________________________
(from 6 to 9 digits)
Multiple Users
1
2
3
4
5
6
7
8
9
£ £ £ £ £ £ £ £ £
Time Delay
• Delay period 1 - 99 minutes
________________________
• Open period 1 - 19 minutes
________________________
Time Delay override
£
• If enabled User #9 will override the Delay Period and open the lock
Dual Mode
£
• Two combinations required to open
Silent Duress Alarm
(Alarm Box Required)
£
• To initiate Duress Alarm Signal, add or subtract 1 to the last digit of the combination(s)
Signal to Disable Lock opening
(Alarm Box Required)
£
• Disable Opening - External signal disables the lock opening by a valid combination
QUICK SETUP VIA KEYPAD
COMBOGARD
PRO
Dual-Handed Swing Bolt or Dead Bolt
Lock Instructions
Lock Choices
Suggested Entry Device
Dual-Handed Swingbolt
Deadbolt
3750-K Entry
ALL LoCKS ARE ShiPPED FRoM ThE FACToRy iN PRE-SETUP MoDE, WiTh No
FEATURES iNSTALLED.
• Lock will open when
1
is pressed.
EXiT PRE-SETUP
(Perform all Administrative Functions with the door open)
1. Press and hold the “0” key until unit double signals.
2. Enter the default Manager Combination, 5-5-5-5-5-5.
• Unit will signal twice and lock will open.
LoCK iS NoW iN SETUP AND TEST MoDE.