background image

Section A. 

La Rose Component Locations

Hand held sprayer

Drain control

On/Off button for CleanJet motor

Water fill valve

Shiatsu massage back

1

Summary of Contents for spas

Page 1: ...Section A La Rose Component Locations Hand held sprayer Drain control On Off button for CleanJet motor Water fill valve Shiatsu massage back 1 ...

Page 2: ...rge pump optional ABS piping from drain to discharge Hot cold hoses Clean Jet pump Drain with P Trap Discharge pump 1 2 outlet Outlet switch Hot Cold flex hose 1 2 outlet Top View Sprayhead Switch for discharge pump optional Knob for drain On Off button for jet LED light switch ...

Page 3: ...nnections The La Rose hot and cold connections are located at the rear of the unit 1 2 Fittings 4 Electrical installation Have a qualified licensed electrician to install the wiring according to local codes The CleanJets are 1 5 hp 120V 15 AMP 60OHZ A GFI protected circuit must be used to supply power to the unit The roller back massage chair uses a 115V supply 5 Secure the base The La Rose base s...

Page 4: ...the sprayer handle This will turn on the water When you release pressure on the thumb control this will turn the water off 5 Adjustable footrest The La Rose utilizes a comfortable 3 position footrest system in which the footrest can be adjusted by pulling out the pin located at the centre of the La Rose base and placing the pin in one of the tree holes situated on the footrest stand You can also s...

Page 5: ...t unless they are supervised at all times 3 Use this unit only for its intended use as described in this manual Do not use attachments that are not recommended by the manufacturer 4 Never drop or insert any object into any opening 5 Do not block jets during whirlpool operation 6 The unit must be connected to an electrical supply circuit that is protected by a ground fault circuit interrupter 7 SAV...

Page 6: ...a with hot water to just above the jets Add disinfectant Run whirlpool for 15 minutes drain and then wipe dry with clean soft cloth NOTE Cleaning or sanitizing is NOT disinfecting According to the Centers for Disease Control and Prevention CDC and the US Environmental Protection Agency EPA disinfecting occurs only when there is a reduction of pathogenic microbes at 99 999 Sanitizing is only a redu...

Page 7: ... bristled brush or cloth and low foam soap to remove any visible residue Rinse with sprayhead Cold water Remove screen by turning counter clockwise Clean back of screen Jet with same soft brush or cloth Rinse with cold water Replace screen by turning clockwise 7 ...

Page 8: ...With discharge pump Section F Specifications 8 52 48 29 37 15 ...

Page 9: ...ble for shipping defective parts back to Gulfstream These parts must be packaged correctly in order to protect against any further damage 4 All parts are to be shipped by UPS Ground Service average 2 5 days 5 All defective parts must be shipped back to Gulfstream withing 30 days of receiving the new replacement parts or warranty will be void 6 Any warranty claim that cannot be determined over the ...

Reviews: