Architects’ and Engineers’ Specification

PLM

 Series: Powered Loudspeaker Management

PLM 10000Q

L a b . g r u p p e n   a b  

  S w e d e n

  i n t e r n a t i o n a L   c o n t a c t  

  i n f o @ L a b g r u p p e n . c o m       |       u S   c o n t a c t  

  i n f o @ t c u S . c o m

w w w . l a b g r u p p e n . c o m

Item no.  AES-PLM10000Q_V2

Overview and Functions

The  unit  shall  comprise  a  two-in/four-out  digital  loudspeaker  drive 
processor with power amplifier outputs. Additional capabilities and 
facilities  shall  include  load  verification  and  real-time  performance 
monitoring;  low-latency,  Ethernet-based  audio  networking;  control 
and monitoring of internal parameters from a remote computer; and 
optional  software  integration  of  industry-standard  acoustical  mea-
surement  tools.  All  control,  monitoring  and  measurement  facilities 
shall be remotely accessible via a custom PC software interface sup-
plied with the unit.

Digital Loudspeaker Processing

The unit shall include two modules of comprehensive digital audio 
processing configured specifically for loudspeaker drive applications. 
Facilities shall be included for raised cosine equalization, linear-phase 
and classical crossovers, peak and rms limiters, and floating ground 
isolation. The processor firmware, in conjunction with supplied PC 
software, shall accommodate flexible mixing and routing, including 
software-driven linkage of processing modules in two or more sepa-
rate units to function as a single module with extended capabilities.

Power Amplifier

Maximum  total  output  of  all  four  channels  shall  be  10,800  watts. 
In discrete four-channel mode, each amplifier channel shall deliver 
maximum  continuous  power  as  follows:  660  watts  into  16  ohms, 
1200  watts  into  8  ohms;  2300  watts  into  4  ohms;  2700  watts 
into 2.7 ohms; or 2350 watts into 2 ohms. When one channel pair  
(A - B or C - D) is driven at -3 dB, maximum continuous output power 
each of the other two channels shall be 2400 watts at 4 ohms and 
2900 watts at 2.7 ohms, with output at other impedances as above. 
Maximum output voltage per channel shall be 150 V; maximum out-
put current per channel shall be 35.5 Arms. Amplifier gain shall be 
adjustable in the DSP input module across a range of 22 to 44 dB in 
0.1 dB increments. 

The  unit  shall  exhibit  the  following  performance  parameters:  
Frequency response shall be 20 Hz to 20 kHz, +/-0.05 dB at 1 watt 
into 8 ohms. Dynamic range with digital inputs (all supported sam-
ple rates) shall be greater than 116 dBA. Propagation delay shall not 
exceed 1.9 ms in the worst-case scenario. The unit shall include a 
DSP-implemented  zero  overshoot  voltage  peak  limiter  individually 
adjustable per channel for maximum voltage between 18 and 150 V 
in 0.1 V increments.

Load Verification and Circuit Protection

The unit’s DSP and on-board firmware, in conjunction with supplied 
PC control software and loudspeaker database, shall enable the unit 
to verify that loudspeaker loads are connected as intended, and to 
identify defective drivers or faulty wiring. The DSP and associated 
software also shall allow real-time monitoring of critical performance 
parameters for both the power amplifier section and connected loud-
speakers. Circuits and sensors shall be provided for warning and pro-
tection against VHF (very high frequencies), DC at output, over-tem-
perature, open load, excessive current, and voltage peak clipping. 

Connectors, Network, and User Interfaces

The rear panel shall provide audio inputs for analog (2) and AES digital 
(1) audio signals on XLR-F connectors, with link outputs for all three 
inputs on adjacent XLR-M connectors. In addition, two EtherCon

®

-

housed RJ45 Ethernet jacks shall be provided for networked digital 
audio as well as monitoring and control via remote PC. The unit shall 
be compatible with use as part of a low-latency, self-configuring digi-
tal audio network that supports sampling frequencies from 44.1 to 
192 kHz. Output connectors on the unit shall be either binding post 
or Neutrik

®

 Speakon

®

 (2 x NLT4 and 1 x NLT8).

The front panel user interface shall include a high-brightness 2.5-inch 
LCD  panel,  a  moisture-resistant  silicone  touch  pad,  and  a  rotary  
encoder. The user interface shall be menu-driven, with screen dis-
plays  and  soft-keys  accessing  functions  of  the  digital  loudspeaker 
processor and the power amplifier. Dedicated keys shall be provided 
for Mute Enable, Meter and Menu functions. Multi-color LEDs shall 
indicate presence of any warning or fault conditions.

The unit shall be supplied with a custom software program for com-
prehensive monitoring of system status and operating parameters, 
as  well  as  control  of  DSP  and  amplifier  functions.  The  software  
program shall be compatible with use on a tablet PC, and shall of-
fer plug-in integration of SmaartLive

®

 audio and acoustical measure-

ment tools in the same user interface.

Power Supply, Protection, and Cooling 

The power supply shall be a regulated switch mode type. The ampli-
fier shall operate from AC line sources of either 230 V nominal or 115 
V nominal (not user selectable), with respective operating ranges of 
130 – 265 V and 65 – 135 V at line frequencies of 50 Hz or 60 Hz. 
Minimum power-up voltages shall be 171 V (230 V nominal) and 85 V 
(115 V nominal). A soft start circuit shall limit current inrush at power-
up to 5 A. The amplifier shall be equipped with an averaging power 
limiter circuit to prevent excessive current draw. The amplifier shall 
be cooled by two temperature-controlled, variable-speed fans, with 
air flow from front to back. An adaptive fan on/off function shall be 
dependent on presence of an output signal. 

Physical

The unit shall be 483 mm (19 in.) wide, 88 mm (3.5 in / 2 U) high, 
and 470 mm (18.5 in.) deep including handles and rear support. The 
weight  shall  be  13  kg  (29  lbs).  The  chassis  housing  shall  be  black 
painted steel with a black painted steel and aluminum front surround 
and handles. 

The unit shall be approved for use as specified by CE, ANSI/UL, ETL 
and the FCC. The unit shall be the Lab.gruppen PLM 10000Q.