Touch Screen Weather Center Model WS-3610
QUICK SET UP GUIDE
1 Shipping
Contents
The shipping contents of the WS-3610 Touch Screen Weather Center include a Base
Station (Receiver), a Thermo-Hygro Sensor (433 MHz Transmitter), a Rain Sensor
and a Wind Sensor, the respective Connecting Cables, an AC Adapter and a CD-
ROM with a Package of PC Software for collected Weather Data.
2 Connections
Connect the Rain Sensor and Wind sensor cables to their respectively marked jacks
in the Thermo-Hygro sensor
BEFORE
powering up the Base Station or the Thermo-
Hygro Sensor.
The Thermo-Hygro Sensor and Base Station can be directly connected via cable if
the wireless 433 MHz radio transmission is not desired, and data transmission free of
localized radio interference is an important factor.
(The use of the direct cable connection between the Base Station and Thermo-Hygro
Sensor depends on the finally chosen operating mode (see Item
3 Power Supply
).
3 Power
Supply
Depending on the type of data transmission from transmitter to receiver the Base
Station and Thermo-Hygro Sensor can be supplied with power in the following
possible combinations:
•
With cable connection or 433 MHz radio transmission: Base Station uses batter-
ies, Thermo-Hygro Sensor uses batteries.
•
With 433 MHz radio transmission: Base Station uses AC/DC adapter, Thermo-
Hygro Sensor batteries.
•
With cable connection: Base Station and Thermo-Hygro Sensor use the AC/DC
adapter.
The last mentioned cable connection eliminates the need for batteries (they may still
be used as backup if there is a power outage) and provides data transmission that is
less prone to interference.
4
To Begin Operation
To begin it is necessary to decide whether to use AC power (adapter included) or
batteries to operate the system. Either method will ensure a connection to the
Thermo-Hygro Sensor and Base Station by cable or by a 433 MHz wireless radio
signal.
Note:
When first setting up the Weather Center, it is important to temporarily
set up the entire system in close proximity on a table or counter top as it is
intended to be used (wired or wireless). This step serves as a test to ensure
that all components function correctly prior to final installation.
In all cases the Thermo-Hygro sensor must be powered up prior to the Base Station
since the Sensor will send an identification code that must be received and stored by
the Base Station within the first few minutes of operation. It is also important to allow
the Base Station to operate for at least 15 minutes prior to touching any fields on the
display.