TAP6000 – 3 in 1 Hot Tap  

 

 

04-17

 

Guarantee (UK only): 

 
Your tap has the benefit of a comprehensive manufacturer’s guarantee, details of which are shown on your 
Proof of Purchase Document. Any claim during the period of the guarantee must be accompanied by the Proof 
of Purchase. The product must be correctly installed and operated in accordance with the manufacturer’s 
instructions and used for normal domestic purposes. This guarantee does not cover accidental damage, 
misuse or alterations which are likely to affect the product. The guarantee is invalid if the product is tampered 
with, or repaired by any unauthorized person. The guarantee in no way affects your statutory or legal rights. 
 

Care Instructions for your Kitchen Sink Mixer: 
 

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. 
A solution of warm water and a mild liquid detergent may be used where necessary, and then the fitting rinsed 
thoroughly and wiped dry. Any other cleaning action will invalidate your warranty.  
 
Abrasive cleaners, scouring cleaners and acidic cleaners 

must not be used 

under any circumstances. Avoid 

contact with all solvents (including chlorinated solvents, ketones or acetones as these may result in surface 
deterioration or etching). Also avoid contact with any harsh household chemicals such as oven cleaners, drain 
cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend or Brasso. 
 
Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to 
maintain optimum flow performance. 

Important Technical Data: 

 

Minimum operating pressure (hot): 0.75 bar 

 

Minimum operating pressure (cold): 2.5 bar (with filter) / 
1.0 bar (without filter) 

Maximum operating pressure: 5.5 bar* 

 

Maximum domestic hot water temperature:  70°C*   

Flow characteristics: Domestic Hot & Cold 
share outer single flow spout. 
Boiled water: Through centre spout channel. 

 

 
Recommended domestic hot water temperature:  46°C 

 
*If these temperatures or pressures are exceeded, even for short periods, damage can result. In these 
instances a thermostatic mixing or pressure reducing valve should be installed. 
 
This product is manufactured in accordance with recognised European standards. Please ensure that your 
kitchen mixer is fitted in accordance with Local Water Byelaws. 

Where hot and cold water mix within the 

tap, then suitable non return (check) valves should be installed to both the hot and cold supplies to 
prevent backflow

, a preinstalled non return valve on the cold supply flexi hose (B1) is already supplied (see 

instructions key). 
 
Hot and cold supply pressures should be as closely balanced as possible for best results. Supply pipes should 
maintain the maximum diameter until immediately before the fitting. The differential between the hot and cold 
water supply temperatures should be sufficient to allow correct mixing function. 
 
These installation guidelines have been prepared for your direction and you must exercise due care at all 
times. We do not accept responsibility for problems that may occur through improper installation. Whilst 
assembling the tap take care not to accidentally loosen any factory fixed assemblies. 
 
This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to 
remain in the tap when delivered. Any water marks can be removed using the above care advice. 

 
 

Summary of Contents for TAP6000

Page 1: ...nce Important Technical Data Minimum operating pressure hot 0 75 bar Minimum operating pressure cold 2 5 bar with filter 1 0 bar without filter Maximum operating pressure 5 5 bar Maximum domestic hot water temperature 70 C Flow characteristics Domestic Hot Cold share outer single flow spout Boiled water Through centre spout channel Recommended domestic hot water temperature 46 C If these temperatu...

Page 2: ...enance Ensure you have suitable domestic hot and cold water pressure before installing this product see technical data for more information All parts should be removed from their packaging and inspected for any transport damage and that all parts are present prior to installation Shut off your water heating system and ensure that your mains stopcock is closed Open the lowest hot and cold taps in t...

Page 3: ...r boiler flexible hose including seal 1 C2 3 8 M x F adaptor 1 C3 NPT M x pushfit 1 C4 outside diameter plastic pipe 1 C5 Filter bracket screw 1 C6 Filter bracket 1 C7 Filter cartridge 1 D1 110 rated hot water hose from boiler output 1 D2 3 8 fibre seal 1 E1 Boiler 1 E2 Flexible boiled water output pipe 1 E3 Connecting tundish assembly 1 E4 Flexible drain pipe 1 Part supplied with boiler pack For ...

Page 4: ...t the filter cartridge C7 under the sink it must be mounted vertically as shown easily accessible to be changed periodically away from any heat source and close enough not to exceed the available length of the plastic pipe C4 supplied 2 Using the self tapping screw C5 securely fix the filter bracket C6 to the cabinet wall 3 Write the installation date onto the filter label in permanent pen then cl...

Page 5: ...xtended periods then flush the product a longer time WARNING THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE ONLY IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND HAVE UNDERSTAND THE HAZARDS INVOLVED CHILDREN SHALL NOT PLAY WITH...

Reviews: