FOR QUALIFIED INSTALLER ONLY

Ice Cooled Dispener Series 2300 & 2400

Operation Manual

PN: 28-0058/03

“Lancer” is the registered trademark of Lancer © 2014 by Lancer, all rights reserved.

2308

2406

ICD 2300 8-Valve Drop In

ICD 2400 6-Valve Free Standing

Summary of Contents for 2300 Series

Page 1: ...tserv lancercorp com lancercorp com Manual PN 28 0058 03 May 1998 FOR QUALIFIED INSTALLER ONLY Ice Cooled Dispener Series 2300 2400 Operation Manual PN 28 0058 03 Lancer is the registered trademark of...

Page 2: ...COUNTER LOCATION 10 1 3 WATER SUPPLY 10 1 4 ELECTRICAL SUPPLY 11 1 5 SYRUP CONTAINERS 11 1 6 INSTALLATION OF THE UNIT 11 1 7 CONNECTION OF THE UNIT 12 1 8 START UP 12 13 1 9 ADJUSTING WATER FLOW 13 1...

Page 3: ...inches 591 mm Depth 23 25 inches 591 mm ELECTRICAL 115 VAC 60 Hz WEIGHT Operating 206 lbs 93 kg Shipping 260 lbs 118 kg ICE Capacity 100 lbs 45 kg FITTINGS Soda water inlet 3 8 barb Brand syrup inlet...

Page 4: ...1377 mm COUNTER CUT OUT Width 23 25 inches 591 mm Depth 24 inches 603 mm ELECTRICAL 24 VAC 60 Hz WEIGHT Operating 290 lbs 132 kg Shipping 196 lbs 89 kg ICE Capacity 100 lbs 45 kg FITTINGS Soda water i...

Page 5: ...Rack BIB Regulator Set BIB Syrup Boxes BIB Connectors ensure you have the correct connectors for syrup lineup 5 TOOLS REQUIRED Oetiker Pliers Slotted Screwdriver Tubing Cutters Phillips Screwdriver Wr...

Page 6: ...los ni os sin supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere l...

Page 7: ...de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la corriente...

Page 8: ...ques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres app...

Page 9: ...local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo menos...

Page 10: ...UPPLY CONTAINS ANY APPRECIABLE AMOUNT OF SILT SAND OR ANY OTHER DEBRIS FAILURE TO DO SO CAN RESULT IN EQUIPMENT DAMAGE PRECAUCI N UN FILTRO EN LA TUBER A DE AGUA DEBE SER USADO SI EL SUMINISTRO DE AGU...

Page 11: ...RS NE BRANCHEZ PAS PLUSIEURS APPAREILS LECTRIQUES LA M ME PRISE DE COURANT 1 4 ELECTRICAL SUPPLY A A standard 15 AMP 110 VAC 60 Hz single phase electrical power outlet with a ground connector should b...

Page 12: ...OMMAGES MAT RIELS E Mount the water filter assembly if required and water regulator if required in a convenient location CAUTION FAILURE TO LIMIT WATER PRESSURE TO 50 PSI 0 345 MPA WILL RESULT IN IMPR...

Page 13: ...e ID panel UP until the flow controls are exposed see Figure 2 D Remove the nozzle by turning the nozzle counter clockwise and pulling down E Remove the diffuser by pulling the diffuser in a downward...

Page 14: ...eded Keep exterior surfaces to include drip tray and cup rest of dispenser cleaned with damp clean cloth 2 2 CLEANING AND SANITIZING SYSTEMS A General Information 1 Lancer equipment new or recondition...

Page 15: ...valves of the disconnect Rinse with clean potable water D Using a mechanical spray bottle and a sanitizing solution prepared in accordance with the instructions in Section 2 2 spray both halves of th...

Page 16: ...alves valve spouts and cup levers Allow to air dry Y Fill ice bin with ice Install ice bin cover on unit NOTE Thoroughly rinse inside and outside of syrup tank that was used for sanitizing solution wi...

Page 17: ...procedure Remove nozzle and diffuser Wash these parts in cleaning solution then immerse them in a bath of sanitizing solution for 15 minutes 2 Visually inspect around nozzle area for syrup residue Thi...

Page 18: ...bonator pump for efficiency 3 2 Noisy Carbonator Pump A Insufficient water supply or water leak allowing air to be pulled into pump B Loose pump coupling A Provide adequate water supply Check strainer...

Page 19: ...DIAGRAMS 5 1 LANCER ICE COOLED DISPENSER ACCESSORIES Illuminated Merchandiser PN 85 2304 T S Valve for Chilled Water PN 19 0036 Illuminated Marquee PN 85 2302 Water Spigot for Ambient Temperature Wate...

Page 20: ...SERIES 2300 DROP IN COVER MUST BE COMPL ET EL Y CLO SE D TO OPE RATE VALV ES SL ID IN G COVER DO NOT LIFT 35 34 33 32 31 30 23 22 21 20 19 18 17 16 15 14 13 12 8 6 11 10 9 5 4 3 1 2 29 28 27 24 25 26...

Page 21: ...52 0827 03 Wire Harness Assy 6 Valve 14 48 0776 Foamed Manifold 5 Valve 4 1 48 0767 Foamed Manifold 6 Valve 5 1 48 0851 Foamed Manifold 5 Valve 2 1 2 48 0850 Foamed Manifold 6 Valve 3 1 2 15 07 0360 P...

Page 22: ...00 FREE STANDING CL OS ED TO OP ER AT E VA LV ES CO VE R MUS T BE CO MPL ET EL Y SL ID IN G CO VER DO NOT LIFT 32 33 30 22 21 20 19 18 17 31 34 35 36 16 15 14 8 11 12 13 7 6 5 4 3 1 2 9 10 29 28 27 26...

Page 23: ...amed Manifold 5 Valve 4 1 48 0767 Foamed Manifold 6 Valve 5 1 48 0851 Foamed Manifold 5 Valve 2 1 2 48 0850 Foamed Manifold 6 Valve 3 1 2 14 07 0360 Plug 15 30 5986 Tower Cap 16 04 0148 Screw 10 32 X...

Page 24: ...P IN WITH PLUG IN TOWERS CL OS ED TO OP ER AT E VA LV ES CO VE R MUS T BE CO MPL ET EL Y DO NO T LIFT SL ID IN G CO VE R 30 22 21 20 19 18 17 31 33 34 35 16 13 14 32 29 15 12 11 10 9 8 7 2 1 3 4 5 6 2...

Page 25: ...re 15 06 0234 Coca Cola Sabre Sign 16 05 0332 Mounting Graphic Panel 17 48 1134 Foamed Manifold 5 Valve Sabre Plug In 48 0744 Foamed Manifold 6 Valve Sabre Plug In 48 1133 Foamed Manifold 5 Valve Stai...

Page 26: ...5 5 SERIES 2400 FREE STANDING WITH PLUG IN TOWERS 32 33 30 22 21 20 19 18 17 31 34 35 36 16 29 15 13 14 12 11 10 9 8 7 4 5 6 27 28 26 25 24 23 3 1 2 26...

Page 27: ...Cola Sabre Sign 16 05 0332 Mounting Graphic Panel 17 48 1134 Foamed Manifold 5 Valve Sabre Plug In 48 0744 Foamed Manifold 6 Valve Sabre Plug In 48 1133 Foamed Manifold 5 Valve Stainless Steel Plug I...

Page 28: ...5 6 SERIES 2300 DROP IN PRE MIX 28 27 23 20 26 18 17 25 16 11 15 10 7 6 5 3 2 1 24 22 14 12 13 19 21 8 9 4 28...

Page 29: ...30 5730 Faucet Plate 6 Valve 11 51 5161 01 Tower Body Stainless Steel 12 07 0360 Plug 13 30 5986 Tower Cap 14 04 0148 Screw 10 32 X 0 250 15 07 0555 Plug 16 C 15 0794 100 Yoke Fitting 17 01 0222 Fitt...

Page 30: ...5 7 SERIES 2400 FREE STANDING PRE MIX 28 27 23 20 26 18 17 16 11 15 10 7 6 5 3 2 1 25 22 14 12 13 19 21 8 9 4 29 24 30...

Page 31: ...0 Faucet Plate 6 Valve 11 51 5161 01 Tower Body Stainless Steel 12 07 0360 Plug 13 30 5986 Tower Cap 14 04 0148 Screw 10 32 X 0 250 15 07 0555 Plug 16 C 15 0794 100 Yoke Fitting 17 01 0222 Fitting 18...

Page 32: ...S NOT USED IN CONJUNCTION WITH ALTERNATE POWER SUPPLY 2F 2F 2M 2F 2M F M WHITE M WHITE F Y WHITE F M WHITE F BLACK BLACK F 2M 2F WHITE WHITE F F WATER SPIGOT BUTTON 2F REPLACES INTERNAL CHERRY SWITCH...

Page 33: ...PLY 2M BLACK WHITE 2M 2F 2F MARQUEE OR MERCHANDISER ALTERNATE POWER SUPPLY 2F 2M F F F F F Y WATER SPIGOT SOLENOID WATER SPIGOT BUTTON WHITE BLACK F Y BLACK WHITE BLACK VALVE MANIFOLD HARNESS 2M 3M 3F...

Page 34: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...