background image

Power

When connecting the 
cable to the device, turn 
the bayonet connector 
90° clockwise until it 
clicks into place.

Use only the supplied 
power adapter.

 

4

Please observe the  
following when setting 
up the device

a

  For devices to be 

operated on the 
desktop, please attach 
the adhesive rubber 
footpads

a

  Do not rest any objects 

on top of the device and 
do not stack multiple 
devices

a

  Keep the ventilation 

slots on the side of 
the device clear of 
obstruction

a

  In case of wall 

mounting, use the 
drilling template as 
suppliedn

a

  Rack installation with 

the optional LANCOM 
Rack Mount (not 
supplied)

LANCOM 1681V

Power

VDSL

Online

ETH 

1

ETH 2 

VP

N

ETH 

3

ETH 4 

 

ISDN Statu

s

VDSL / ADSL  interface

Use the supplied DSL cable 
for the IP-based line to 
connect the VDSL / ADSL 
interface and the provider’s 
telephone socket. For more 
information, please contact 
your Internet service 
provider.

LANCOM, LANCOM S

ystems and L

COS ar

e r

egister

ed tr

ademarks. All other names or descriptions used may be tr

ademarks or r

egister

ed

 

 tr

ademarks of their owners. Subject to change without notice. No liability for technical err

ors and/or omissions.                111634/0617 

  

TECHNIC

AL DET

AILS

Hardware

Power supply

12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection

Power consumption

Max. ca. 14 W

Environment

Temperature range 0–35 °C, humidity 0–95 %; non-condensing

Housing

Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock;  
measures 210 x 45 x 140 mm (W x H x D)

Number of fans

None; fanless design, no rotating parts, high MTBF

Interfaces

LANCOM 1783VAW over ISDN / over POTS

WAN: VDSL2

 

A

VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a

 

A

Compatible to VDSL2 from Deutsche Telekom AG (only over ISDN)

 

A

ADSL conformity according to: 
ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO (POTS: Annex A/Annex M), 
ADSL2 over ISDN as per ITU G.992.3 Annex B (POTS: Annex A/L), 
ADSL over ISDN as per ITU G.992.1 Annex B (POTS: Annex A)

 

A

Supports just one virtual connection at a time in ATM (VPI-VCI pair)

Wi-Fi

 

A

Frequency band: 2400-2483.5 MHz (ISM) or 5150-5825 MHz (restrictions vary between countries)

 

A

Radio channels 2.4 GHz: Up to 13 channels, max. 3 non-overlapping (2.4-GHz band)

 

A

Radio channels 5 GHz: Up to 26 non-overlapping channels (channels available vary according to 
country regulations; DFS for automatic dynamic channel selection required)

ETH

4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.  
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in 

the LCOS configuration.

USB

USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port 

server) or USB drives (FAT file system)

ISDN 1 / ISDN 2

ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the 
settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device. 
ISDN 2: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to the ISDN 
interface;

Analog 1 / Analog 2

Use the cable of your analog devices to connect them with the analog interfaces. If necessary, use the 
enclosed adapter.

Config (Com) / V.24

Serial configuration interface / COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for optio

-

nal connection of analog/GPRS modems. Supports internal COM-port server and provides transparent 
asynchronous serial-data transfer via TCP.

WAN protocols

VDSL, ADSL, Ethernet

PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP), RIP-
1, RIP-2, VLAN, GRE, EoGRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and 

IPv4/IPv6 dual stack session), IP(v6)oE (autoconfiguration, DHCPv6 or static)

ISDN

DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD

Declaration of Conformity

Hereby, LANCOM Systems declares that this radio equipment is in compliance with Directive 2014/53/EU. The full text of the EU 
declaration of conformity is available at the following internet address: www.lancom-systems.com/ce/

Package content

Manual

Quick Reference Guide (DE/EN), Installation Guide (DE/EN)

Cable

1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m; 
1 ISDN cable, 3 m (light-blue connectors)

Adapters

2 TAE adapters (RJ11 - TAE)

Power adapter

External power supply adapter (230 V); NEST 12 V / 1.5 A DC/S; barrel connector 2.1 / 5.5 mm  
bayonet; LANCOM Art.-Nr. 111301 (EU, 230 V); LANCOM Art.-Nr. 111302 (UK, 230 V)

MOUNTING AND CONNEC

TING THE DEVICE

i

 

VPN

Off

VPN connection inactive

Green, permanently

VPN connection active

Green, flashing

VPN connecting

e

 

ISDN

Off

Interface deactivated

Green, permanently

D-channel active

Green, flickering

ISDN data transfer

Red, flickering

ISDN transfer error

Red/orange, blinking

ISDN hardware error

a

 

Power

Off

Device switched off

Green, permanently*

Device operational, resp. device paired / 
claimed and LANCOM Management Cloud 
(LMC) accessible

Green/red, blinking

No password set. Without a password 

the configuration data in the device is 

unprotected.

Red, blinking

Charge or time limit reached

1x green inverse 
blinking*

Connection to the LMC active, pairing OK, 
device not claimed

2x green inverse 
blinking*

Pairing error, resp. LMC activation code 
not available

3x green inverse 
blinking*

LMC not accessible, resp. communication 
error

b

 

Online

Off

WAN connection inactive

Green, permanently

WAN connection active

Red, permanently

WAN connection error

c

 

DSL

Off

Interface deactivated

Green, permanently

DSL connection active

Green, flickering

DSL data transfer

Red, flickering

DSL transfer error

Red/orange, blinking

DSL hardware error

Orange, blinking

DSL training

Orange, permanently

DSL sync

Green, blinking

DSL connecting

d

 

Analog

Off

Interface deactivated

Green, permanently

Interface activated

Orange, blinking

Incoming call

Green, blinking

Connection active

h

 

VoIP

Off

No SIP accounts defined or VCM is off

Green, permanently

All defined and active SIP accounts (outgoing) 

were successfully registered

Red, permanently

Not all of the defined and active SIP accounts 

were registered (possibly still in process)

Red or green, 

inverse flashing

Number of currently used lines  
(connecting or connected)

f

 

ETH

Off

No networking device attached

Green, permanently

Connection to network device operational,  

no data traffic

Green, flickering

Data transmission

g

 

WLAN

Off

No Wi-Fi network defined or Wi-Fi module 

deactivated. The Wi-Fi module is not  
transmitting beacons.

Green, permanently

At least one Wi-Fi network is defined and 

 

Wi-Fi module activated. The Wi-Fi module  
is transmitting beacons.

Green, blinking

DFS scanning or other scan procedure

j

 

Reset

Reset switch

Operated e.g. with a paper clip 
short press > Restart the device 
long press > Reset the device

Analog   interface

Connect analog terminal 
devices to the analog 
interfaces either directly  
via RJ11 or with the help  
of the enclosed TAE 
adapter.

Serial   interface 

Configuring the device 

via the serial interface 
requires a serial 

configuration cable 

 

(available as an 
accessory).

ISDN   interface 

ISDN 1
Internal (NT) or  
external (TE) ISDN bus. 
This feature is controlled 
by LCOS.

ISDN 2
Internal (NT) ISDN-bus.

A 100-Ohm resistor for 
line termination is 
switchable in LCOS.

USB   interface

You can use the USB 
interface to connect 
a USB printer or a 
USB drive.

Ethernet   interface

Use the cable with  
the green-colored  
connectors to connect 
one of the interfaces 
ETH 1 to ETH 4 to your 
PC or a LAN switch.

b

c

d

e

f

g

a

LANCOM 1783VAW

Quick Reference Guide

Cloud-ready

LANCOM 1783VAW

DSL

ETH 2

Power

ETH 1

Online

ISDN 1

ETH 4

ETH 3

VPN

Analog 1

Analog 2

ISDN 2

WLAN

Reset

VoIP

a c

e

b

g

f

d

i

h

j

*) The additional power LED statuses are displayed in 5-seconds 

rotation if the device is configured to be managed by the LANCOM 

Management Cloud.

This product contains separate open-source software components which are subject to their own licenses, in particular the 

General Public License (GPL). The license information for the device firmware (LCOS) is available on the device‘s WEBconfig 
interface under “Extras > License information“. If the respective license demands, the source files for the corresponding software 

components will be made available on a download server upon request.

Gigabit Ethernet 10/100/1000

ISDN 1

ISDN 2

TE / NT

NT

Analog 1

Analog 2

VDSL / ADSL

a

b

c

d

e

f

g

Reviews: