Included hardware
Tools Required
•
Safety glasses
•
Screwdrivers
•
Wiring tools and connectors, for performance or wayfinding bollard
•
1/2” wrench or socket
•
Hammer drill, with 1/2” dia bit
•
5/64 hex key, 5mm hex key
•
Epoxy anchoring system for concrete
ASSEMBLE WITH CARE!
Pangard II
Polyester Powdercoat is a strong, long-lasting finish. To protect this finish
during assembly, place unwrapped powdercoated parts on packaging foam or other non-marring surface. Do not
place or slide powdercoated parts on concrete or other hard or textured surface – this will damage the finish
causing rust to occur. Use touch-up paint on any gouges in the finish caused by assembly tools.
LIGHTING LAYOUT RECOMMENDATIONS:
Profile bollard spacing is the responsibility of others. Refer to the Product Data Sheet,
, for light distribution options.
Installation Guide
Profile
unlit perimeter bollard, wayfinding bollard, performance bollard
www.landscapeforms.com Ph: 800.521.2546
Date: May 20, 2022
Page 1 of 3
Fig. 1 – Recommended setback
from sidewalk
SIDEWALK
Fig. 3 – Minimum footing recommendation
[57mm]
2 1/4” MAX
[50mm]
2” MIN
Fig. 2 – Minimum concrete slab size
EDGE OR
EXPANSION
JOINT
Fig. 4 – Base plate detail
BW103-2
BW103-3
BW102-2
BW102-3
BW101-T4
BW101-T5
Anchor
Template
-1X
Concrete
Anchor
-4X
5/16-18 x
1-1/4” hex hd bolt
-4X
5/16 washer
-4X
footcover bracket
2X – unlit bollard
1X – lit bollard
footcover casting
2X – unlit bollard
1X – lit bollard
#8-32 Set screw for
footcover casting
2X – unlit bollard
1X – lit bollard
Installed in casting