background image

Star Manufacturing International 

10 Sunnen Drive 

St. Louis, MO 63143 

Part Number: 2M-W358 

Phone: 314-781-2777   Fax: 314-781-2714 

Rev. F 

WWW.STAR-MFG.COM

 July 

9, 

2009 

 

 

 

 

 

Installation, 

Operations, and 

Maintenance Instructions 

Gas Griddle, Spark Ignition, “ACCU-TEMP” 

Model:  

224T 224TH 

224THG  224SHG 

236T 236THE 

236THG 

248T 248TC 

248TCHE 

248THE  248THG 

 

260T 260TC 

 

260TCHG 

260THE  260THG 

272T 272THG 

272TNTS 

 

Summary of Contents for 224TH

Page 1: ...e 314 781 2777 Fax 314 781 2714 Rev F WWW STAR MFG COM July 9 2009 Installation Operations and Maintenance Instructions Gas Griddle Spark Ignition ACCU TEMP Model 224T 224TH 224THG 224SHG 236T 236THE 236THG 248T 248TC 248TCHE 248THE 248THG 260T 260TC 260TCHG 260THE 260THG 272T 272THG 272TNTS ...

Page 2: ...GE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT IMPORTANT The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 LATEST EDITION AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN CGA B149 1 NATURAL GAS I...

Page 3: ...AD FIRST 4 3 EQUIPMENT DESCRIPTION 6 4 UNPACKING 8 5 INSTALLATION 10 6 GRIDDLE SURFACE CARE 11 7 CHROME WARRANTY 12 8 INITIAL START UP 13 9 OPERATION 14 15 10 MAINTENANCE CLEANING PROCEDURES 16 11 TROUBLESHOOTING 18 12 PARTS LIST 19 24 13 WIRING DIAGRAMS 25 26 ...

Page 4: ...TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located inside the control compartment of each griddle The griddle voltage serial number gas specifications and clearance specifications are on the data plate This information should be carefully read and understood before proceeding with the installation NOTICE The insta...

Page 5: ...an cause corrosion CAUTION GRILL CALIBRATION REQUIRES DISASSEMBLY OF THE THERMOSTAT AND SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY IT IS GENERALLY MORE COST EFFECTIVE TO REPLACE A THERMOSTAT THAT IS OUT OF CALIBRATION NOTICE Service on this or any other LANG appliance must be performed by qualified personnel only Consult your LANG Authorized Service Agent Directory or call the factory at 1 80...

Page 6: ...ddle 3 2 Operation Each twelve inch section has its own snap action thermostat and gas valves that are fully on or fully off 3 3 Controls The ACCU TEMP Griddle comes with thermostat controls 3 4 Technical Griddle operates on either Natural gas or Propane This must be specified when ordering It is shipped with a Power Cord and Plug attached Floor space required is 30 76 20cm Deep and width is 2 ft ...

Page 7: ...T 2 SUPPLIED 272T 72 INCHES 162 000 162 000 TWO 3 4 NPT 115 VOLT 2 SUPPLIED SPECIFICATIONS AND INFORMATION GRILL SURFACE OVERALL CLEARANCE FROM COMBUSTIBLE SURFACES MODEL NUMBER WIDTH DEPTH SQUARE INCHES OF GRIDDLE NUMBER OF BURNERS NUMBER OF CONTROLS NUMBER OF GREASE DRAWERS SIDES BACK BOTTOM SHIPPING WEIGHT 224T 24 INCHES 23 INCHES 552 2 2 1 5 INCHES 5 INCHES 4 INCH LEG 260 236T 36 INCHES 23 INC...

Page 8: ... near its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 4 3 Un crating The griddle will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid Remove the cardboard cover cut the straps and remove the wood frame CAUTION THE GRIDDLE EXTREMELY HEAV...

Page 9: ...ust be wired by a licensed electrician and in accordance with local codes or in the absence of local codes with NFPA No 70 latest edition in Canada use CSA STD C221 5 2 Gas Connection This griddle is manufactured for use with the type of gas indicted on the nameplate Contact the factory if your type of gas does not match the nameplate data All gas connectors must be in accordance with local codes ...

Page 10: ...hould be used that is resistant to the action of liquid petroleum gas Initial adjustments are the responsibility of the installer and are not chargeable to Star Manufacturing International After the griddle is in its final position adjust the legs to create 1 8 inch slant from back to front This will allow the grease to run into the grease gutter and provide the proper combustion air for the burne...

Page 11: ...wash in the same way as an ordinary cooking utensil The drawers are removed by pulling forward until they are released from their track GRIDDLE CARE CHROMIUM SURFACES It takes very little time and effort to keep this Industrial Chromium griddle surface sparkling clean and performing at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent t...

Page 12: ...Incorporated or one of its authorized representatives that the chrome surface has been misused or abused or subjected to the following situations 1 Improperly installed 2 Incorrect voltage applied to electric Chrome Max units allowing the surface to overheat and discolor 3 The misuse of any instrument or tool which scratches or makes indentations in the surface which could cause the surface to pee...

Page 13: ...ch to STANDBY 6 2 Seasoning the Griddle Plate NON CHROME ONLY Set the temperature dials to 300 F 148 C Observe the burners through the opening at the top of the control panel When the burners go OFF apply a thin coat of high grade non salted vegetable oil to the griddle surface Rub the oil into the griddle surface with the flat side of a spatula or a towel Recoat any dry spots that appear then wai...

Page 14: ...5 F 190 C 5 to 7 3 4 to 1 inch thick cooked medium 375 F 190 C 8 to 10 Lamb Chops 350 F 176 C 6 to 8 Pork Chops 350 F 176 C 6 to 8 Salmon 350 F 176 C 6 to 8 Halibut 325 F 162 C 6 to 8 Snapper 325 F 162 C 6 to 8 Hashbrown Potatoes 375 F 190 C 3 to 4 Bacon 350 F 176 C 3 to 4 Sausage Links or Patties 350 F 176 C 3 to 4 Ham Pre cooked 375 F 190 C 2 Eggs 275 F 135 C 2 to 4 Note The times and temperatur...

Page 15: ...iddle temperature 7 2 Sequence of Operation When the griddle is connected to 115 Volt Power the spark module for each section starts sparking While they are sparking the solenoid valve for the pilot burners are energized When the individual pilot burners ignite and the pilot flame is verified the spark module will stop sparking Note The pilot burners will remain lit until the griddle is removed fr...

Page 16: ...E COST EFFECTIVE TO REPLACE A THERMOSTAT THAT IS OUT OF CALIBRATION 8 1 Daily Cleaning Empty the grease drawer daily or whenever it is 3 4 full It is easily removed for washing Keep the non chromed griddle surface clean After each cooking load scrape the griddle surface to remove any carbonized grease Once a day or when necessary the non chromed griddle surface should be thoroughly cleaned and sea...

Page 17: ...e dials to 350 F 176 C Allow the burners to cycle ON and OFF at least five times before attempting to calibrate Place a surface thermometer in the center of each cooking section to be calibrated Allow the burners to cycle several times while recording the temperature at which the burners turn ON and OFF Average the temperatures together if the average temperature is within 10 of the set temperatur...

Page 18: ...tify test procedures SYMPTON POSSIBLE CAUSE Entire griddle not lighting Failed regulator or plugged regulator vent Failed transformer Power indicator is not lit No power to cord outlet Griddle unplugged from outlet Failed power cord or plug Failed power switch Failed pilot light Section will not heat Plugged pilot orifice Failed thermostat Failed gas valve Product burning Product is cooked too lon...

Page 19: ...ace thermostat Failed transformer Check transformer for correct voltage replace as necessary Failed igniter Replace as necessary Failed spark module Check for correct incoming voltage at module Failed power cord or plug Check cord and plug for proper voltage Failed power switch Check switch for continuity across poles Failed pilot light Check for continuity across pilot light leads Failed gas valv...

Page 20: ...HT 1 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 1 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2J 80300 03 SPRK IGNITR MODULE SM2 2 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2T 30402 27 ST...

Page 21: ...236T LP NAT THE NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 236T LP NAT THE NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 2 236T LP NAT THE NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 236T LP NAT THE NAT 2J 80300 03 SPRK IGNITR MODULE SM2 3 236T LP NAT THE NAT 2T 30402 27 STAT ADJ 450 DEG 48 PILOT 3 236T LP NAT THE NAT 2V 80501 04 GAS REG 3 4X3 4 CLS I 1 236T NAT THE NAT THG LP 2V 80501 05 GAS REG 3 4X3...

Page 22: ... HOLE 4 248T LP NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 248T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 3 248T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 248T LP NAT 2J 80300 03 SPRK IGNITR MODULE SM2 4 248T LP NAT 2T 30402 27 STAT ADJ 450 DEG 48 PILOT 4 248T LP NAT 2V 80501 04 GAS REG 3 4X3 4 CLS I 1 248T NAT 2V 80501 05 GAS REG 3 4X3 4 CLS II 2 248T LP 2V 80501 07 REGULATOR CONV SPRG NG ...

Page 23: ...EAD WHT 1 260T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 4 260T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 260T LP NAT 2J 80300 03 SPRK IGNITR MODULE SM2 5 260T LP NAT 2T 30402 27 STAT ADJ 450 DEG 48 PILOT 5 260T LP NAT 2V 80501 04 GAS REG 3 4X3 4 CLS I 1 260T NAT 2V 80501 05 GAS REG 3 4X3 4 CLS II 1 260T LP 2V 80501 07 REGULATOR CONV SPRG NG TO 1 260T NAT 2V 80502 03 SLENOID VLVE 24VAC 1 2...

Page 24: ... 42 HOLE 6 272T LP NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 272T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 4 272T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 2 272T LP NAT 2J 80300 03 SPRK IGNITR MODULE SM2 6 272T LP NAT 2T 30402 27 STAT ADJ 450 DEG 48 PILOT 6 272T LP NAT 2V 80501 04 GAS REG 3 4X3 4 CLS I 1 272T NAT 2V 80501 04 GAS REG 3 4X3 4 CLS I 2 272THG NAT 2V 80501 05 GAS REG 3 4X3 4 CL...

Page 25: ...25 ...

Page 26: ......

Page 27: ...VALVE THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT TERMINAL BLOCK POWER CORD YEL YEL 12 YEL 13 YEL 20 YEL 27 YEL 34 YEL 41 YEL 48 YEL BLK BLK WHT WHT GRN BLK BLK 7 BLK 14 BLK 21 BLK 28 BLK 35 BLK 42 BLK 1 BLK 2 WHT 8 WHT 15 WHT 22 WHT 29 WHT 36 WHT 43 WHT 4 YEL 19 YEL 26 YEL 33 YEL 40 YEL 47 YEL 11 BLU 10 BLU 18 BLU 17 BLU 25 BLU 24 BLU 32 BLU 39 BLU 31 BLU 38 BLU 46 BLU 45 BLU 5 BLU 6 B...

Page 28: ...STAR MANUFACTURING GROUP Star Holman Lang Wells Bloomfield 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com ...