PL Instrukcja montażu i użytkowaniaEN Operating and installation instructionsDE Gebrauchs- und Montageanleitung
PL Okap kuchenny do zabudowyEN Built-in range hoodDE Einbau-Dunstabzugshaube
Seletio
Seletio 60
Page 1: ...strukcja monta u i u ytkowania EN Operating and installation instructions DE Gebrauchs und Montageanleitung PL Okap kuchenny do zabudowy EN Built in range hood DE Einbau Dunstabzugshaube Seletio Selet...
Page 2: ...POD CZENIE ELEKTRYCZNE CZYSZCZENIE I KONSERWACJA FILTR W GLOWY FILTR PRZECIWT USZCZOWY STEROWANIE PRAC OKAPU CO ROBI W RAZIE NAPOTKANIA PROBLEMU ETYKIETA ENERGETYCZNA SPOSOBY ZMNIEJSZENIA WP YWU PROC...
Page 3: ...jej zachowanie aby m c z niej skorzysta w ka dej chwili Zesp LANILIA Dla zapewnienia Pa stwu maksymalnego bezpiecze stwa w u ytkowaniu zakupionego urz dze nia najwa niejsze tre ci niniejszej instrukc...
Page 4: ...wo zapali Zasysane powietrze przez okap nie mo e by odprowadzane do kana u kominowego s u cego do odprowadzania spalin z urz dze spalaj cych gaz lub inne paliwo nie dotyczy to okap w z obiegiem zamkni...
Page 5: ...ektrycznego i elektronicznego oraz baterii Prowadz cy punkty zbi rki w tym lokalne punkty zbi rki sklepy oraz gminne jednostki tworz odpowiedni system umo liwiaj cy oddanie tego sprz tu oraz baterii j...
Page 6: ...ZBIE ZAGI K TY ZAGI NIE POWINNY BY WI K SZE NI 90 STOPNI NIE ZALECA SI STOSOWANIA ZMIAN PRZEKROJU PRZEWODU WI KSZEGO NA MNIEJSZY NP WYLOT POWIETRZA 15 CM NA WYLOT POWIETRZA 12 CM ZADBAJ ABY W POMIESZC...
Page 7: ...trukcji obs ugi urz dzenia grzewczego podana jest wi ksza od leg o ni wskazana powy ej dostosuj si do takich wskaza Monta okapu przedstawiony jest na rysunkach Rys 5 Rys 11 W trakcie jego przeprowa dz...
Page 8: ...y znajduj ce si w pobli u wykonywanych prac Sprawd czy w pobli u strefy montowania okapu znajduje si gniazdko wtykowe i czy mo na pod czy okap do przewodu wentylacyjnego odprowadzaj cego opary na zewn...
Page 9: ...9 PL INSTALACJA OKAPU 1 Przygotuj szafk do monta u okapu wycinaj c otw r w spodzie szafki zgodnie z rysunkiem Seletio 60 Rys 5 2 Wymontuj filtr aluminiowy przeciwt uszczowy Rys 6...
Page 10: ...10 PL 3 Wsu okap w otw r przytrzymuj c okap jedn r k od do u lub popro o pomoc Zamocuj okap wybieraj c jeden wariant mocowania a mocowanie do p ki szafki Rys 7 320 180 160 ruby do metalu 4x26 x4...
Page 11: ...oku szafki Listwy boczne nie s elementami zestawu Nale y je dobra w zale no ci od rozmiar w szafki Ich grubo mo na obliczy ze wzoru g D 430 2 mm gdzie D to wewn trzna szeroko szafki a g to grubo listw...
Page 12: ...12 PL Rys 9 c mocowanie do boku szafki wkr ty do drewna 4x16 x4...
Page 13: ...tuj filtr przeciwt uszczowy i zamknij jego os on 5 Pod cz rur do kr ca silnika Rys 10 Rys 11 UWAGA PO ZAKO CZENIU MONTA U NALE Y USUN WSZYSTKIE FOLIE ZABEZPIECZAJ CE Z OKAPU I JEGO ELEMENT W FILTRY MA...
Page 14: ...j agodne rodki myj ce Nie u ywaj rodk w ciernych Czyszczenie okapu wykonuj przynajmniej raz w miesi cu lub co 35 godzin pracy okapu Do mycia okapu w adnym wypadku NIE U YWAJ RODK W NA BAZIE ALKOHOLU E...
Page 15: ...zmywarce Po wyczyszczeniu mo esz zaobserwowa delikatne odbarwienie filtra co nie ma wp ywu na jego w a ciwo ci Filtr kt ry nie jest regularnie czyszczo ny zmniejsza wydajno okapu i mo e przyczyni si...
Page 16: ...y Wydajno jest niewystarczaj ca okap pracuje g o niej ni powinien Sprawd czy przekr j przewodu wentylacyjnego jest wystarczaj cy i czy nie ma zbyt du o za ama i ostrych k t w Sprawd czy w kanale wenty...
Page 17: ...w przy aktualnej intensywno ci gotowania SERWIS Je eli pomimo naszej dok adnej kontroli jako ci stwierdz Pa stwo nieprawid owo ci w pracy i funkcjonowaniu zakupionego urz dzenia prosimy o kontakt z n...
Page 18: ...no wyczyszczenia lub wymiany filtra przeciwt uszczowego Naci nij i przytrzymaj przez ok 6s pole na panelu dotykowym Umyj filtr lub wymie na nowy Wy wietlacz pokazuje jedynie znak minus oraz kropka w p...
Page 19: ...jest w tryb turbo kt ry po 5min pracy automatycznie zmienia bieg na trzeci w celu oszcz dzania energii Trybu turbo nale y u ywa jedynie przy intensywnym gotowaniu Okap mo na obs ugiwa jedynie za pomo...
Page 20: ...ZKODZENIA MECHANICZNE KT RY MIMO TO ZOSTA ZAMONTOWANY NIE PODLEGA WYMIANIE PRZED MONTA EM OKAPU NALE Y GO ROZPAKOWA DOKONA DOK ADNYCH OGL DZIN POWIERZCHNI ORAZ SPRAWDZI KOMPLETNO WYPOSA ENIA W CELU ZI...
Page 21: ......
Page 22: ...BEFORE HOOD INSTALLATION HOOD INSTALLATION POWER SUPPLY CONNECTION CLEANING AND MAINTENANCE CARBON FILTER ANTI GREASE FILTER SETTINGS IN CASE OF PROBLEMS ENERGY LABEL REDUCING THE IMPACT OF COOKING ON...
Page 23: ...asily accessible place so that you can consult it at any time LANILIA team In order to ensure the maximum safety of the device the most important information has been marked with the following symbol...
Page 24: ...eep frying overheated fat can easily ignite The air sucked in by the hood must not be discharged into a flue pipe used for exhaust fumes from appliances burning gas or other fuels this does not apply...
Page 25: ...ectrical and electronic equipment and batteries if any to special collection points for such items Operators of collection facilities including local collection points shops and municipal units must h...
Page 26: ...BENDING OF THE DUCT SHOULD BE LIMITED TO MINIMUM THE ANGLES SHOULD NOT EXCEED 90 COMBINING DUCTS WITH DIFFERENT CROSS SECTIONS IS NOT RECOMMENDED E G 15 CM WITH 12 CM ENSURE THAT THE SIZE OF THE SUCTI...
Page 27: ...he cooker manual indicates a greater distance than specified above follow the instructions in the cooker manual Installation of the product is shown in Figures 5 11 During installation follow the gene...
Page 28: ...is is not possible secure these ele ments Check whether there is a socket near the hood installation space and whether it is possible to connect the hood to a ventilation duct for fume extraction Make...
Page 29: ...29 EN Fig 5 Fig 6 Seletio 60 HOOD INSTALLATION 1 Prepare the hood installation cabinet by disassembling the bottom shelf as shown in the figure 2 Remove the aluminium anti grease filter...
Page 30: ...hood into the pre cut hole holding the bottom of the exhaust hood with one hand or ask for help Fix the exhaust hood by choosing one of the mounting options a fixing to the shelf of a kitchen cupboard...
Page 31: ...part of the set They must be selected according to the size of the kitchen cupboard Their thickness can be calculated using the formula g D 430 2 mm where D is the internal width of the kitchen cupbo...
Page 32: ...32 EN c fixing to the side of a kitchen cupboard Fig 9 wood screws 4x16 x4...
Page 33: ...33 EN Fig 10 Fig 11 CAUTION AFTER INSTALLATION REMOVE ALL PROTECTIVE FILMS FROM THE HOOD AND ITS COMPONENTS FILTERS GRILLES ETC 4 Install the grease filter 5 Connect the duct to the motor connection...
Page 34: ...tergents for cleaning Do not use abrasive cleaning products The hood should be cleaned at least once a month or every 35 hours of operation DO NOT USE ALCOHOL BASED CLEANING AGENTS Inox parts should b...
Page 35: ...ing you may notice a slight discolouration of the filter which does not affect its properties A regularly cleaned filter will help to maintain the efficiency of the hood and prevent the risk of fire S...
Page 36: ...it back in Insufficient efficiency noisy operation Check whether the cross section of the ventilation duct is sufficient and whether it has not too many bends and sharp angles Check if the return flap...
Page 37: ...me extraction at the current cooking intensity SERVICE AND MAINTENANCE If despite our strict quality control you find any irregularities in the operation and functioning of the purchased device please...
Page 38: ...or approx 6s the button on the panel Clean the filter or replace it with a new one The display only shows the sign minus and dot in the lower right corner the hood does not start when switched on The...
Page 39: ...and on the website Problem Possible reason Solution Number 4 on the display is blinking and after 5 min the speed level changes to 3 The hood is equipped with a turbo mode which automatically changes...
Page 40: ...ANY MISSING COMPONENTS OR DAMAGE ANY VISIBLE EXTERNAL DAMAGE CLAIMED AFTER INSTAL LATION IS EXCLUDED FROM THE WARRANTY LANILIA SHALL NOT BE HELD LIABLE FOR DAMAGE CAUSED DIRECTLY OR INDIRECTLY BY PERS...
Page 41: ...DER DUNSTABZUGSHAUBE ELEKTRISCHER ANSCHLUSS REINIGUNG UND WARTUNG KOHLEFILTER FETTFILTER STEUERUNG DER DUNSTABZUGSHAUBE WAS IST BEI PROBLEMEN ZU TUN ENERGIEETIKETT METHODEN ZUR REDUZIERUNG DER UMWELTE...
Page 42: ...diese Gebrauchs und Montageanleitung gut aufzubewahren damit Sie jederzeit auf sie zugreifen k nnen LANILIA Team Um Ihnen maximale Sicherheit bei Gebrauch des von Ihnen gekauften Ger tes zu gew hrlei...
Page 43: ...gshaube angesaugte Luft darf nicht in die Abgasleitung ber die bei der Verbrennung von Gas oder anderen Brennstoffen erzeugte Abgase abgeleitet werden eingeleitet dies gilt nicht f r Dunstabzugshauben...
Page 44: ...rische und elektronische Ger te und Batterien zu bergeben Die Betreiber von Abfallssammelstellen darunter auch von lokalen Abfallssammelstellen Gesch ften und kommunalen Abfallssammelstellen bilden ei...
Page 45: ...GRAD BETRAGEN ES WIRD NICHT EMPFOHLEN VON EINEM LEITUNGSDURCHMESSER IN EINEN ANDEREN ZU WECH SELN VON EINEM H HEREN DURCHMESSER IN EINEN GERINGEREN DURCHMESSER Z B VON EINEM LUFTAUSLAUF 15 CM IN EINEN...
Page 46: ...t in der Gebrauchsanleitung des jeweiligen Herdes ein Abstand angegeben der h her als der hier genannter Abstand ist ber cksichtigen Sie solche Vorgaben Die Dunstabzugshaubemontage ist auf den Abbildu...
Page 47: ...Installationsarbeiten vorhandenen Gegenst nde Pr fen Sie ob in der N he der Dunstabzugshaubemontagezone eine Steckdose vorhanden ist und ob die Dunstabzugshaube an eine L ftungsleitung die D nste nach...
Page 48: ...N DER DUNSTABZUGSHAUBE 1 Bereiten Sie einen Schrank zur Montage der Dunstabzugshaube indem Sie gem der Zeich nung eine Bohrung im Schrankboden herstellen Abb 5 2 Bauen Sie den Aluminium Fettfilter aus...
Page 49: ...ie Abzugshaube in die fr her hergestellte ffnung wobei Sie die Abzugs haube mit einer Hand halten oder bitten Sie jemanden dass er Ihnen dabei hilft Befestigen Sie die Abzugshaube indem Sie eine der B...
Page 50: ...and Abb 8 Die Seitliche leisten werden mit dem Set nicht mitgeliefert Sie sind je nach w Schrankma en anzupassen Ihre St rke kann man nach folgender For mel errechnen g D 430 2 mm wobei D innere Schra...
Page 51: ...51 DE Holzbohrschrauben 4x16 x4 Abb 9 c Befestigung and der seitlichen Schrankwand...
Page 52: ...4 Den Fettfilter einsetzen 5 Verbinden Sie das Rohr mit dem Motorstutzen ACHTUNG NACH DEM ABSCHLUSS DER INSTALLATION ENTFERNEN SIE ALLE SCHUTZFOLIEN VON DER DUNSTABZUGSHAUBE UND IHREN BESTANDTEILEN FI...
Page 53: ...enden Sie keine Schleifmittel Reinigen Sie die Dunstabzugshaube zumindest einmal im Monat oder immer nach 35 Betriebsstunden Zur Reinigung der Dunstabzugshaube VERWENDEN SIE AUF KEINEN FALL REINIGUNGS...
Page 54: ...rbung des Filters feststellen das hat aber keine Einwirkung auf sei ne Eigenschaften Ein Filter welches nicht regelm ig gereinigt wird verringert die Leistung der Dunstabzugshaube und kann auch dazu b...
Page 55: ...Die Leistung ist nicht ausreichend die Dunstabzugshaube funktioniert lauter als blich Pr fen Sie ob der Durchmesser der L ftungsleitung ausreichend gro ist und ob es nicht zu viele Knicke und spitze...
Page 56: ...ters zwischen den Reinigungsvorg ngen betr gt max 35 Betriebsstunden der Dunstabzugshaube Sorgen Sie daf r dass L ftungsleitungen nicht verstopft werden Beim Kochen stellen Sie immer die minimale Dreh...
Page 57: ...essionelle Hilfe bekommen k nnen Das Servicepersonal steht f r Sie von Montag bis Freitag von 9 00 Uhr bis 17 00 Uhr zur Ver f gung Tel Nr 48 17 78 52 251 und Mobil 48 609 055 660 oder E Mail serwis l...
Page 58: ...altfl che mit einem Plussymbol zu bet tigen und dann ca 10 Sekunden lang gedr ckt zu halten oder die Dunstabzugshaube ist auszuschalten Bei der vierten Drehgeschwindig keitsstufe blinkt die Ziffer 4 a...
Page 59: ...s Ger tes ACHTUNG WAREN MIT MECHANISCHEN SCH DEN DIE DENNOCH INSTALLIERT WURDEN WERDEN NICHT AUS GETAUSCHT VOR MONTAGE DER DUNSTABZUGSHAUBE IST SIE AUSZUPACKEN DIE OBERFL CHE GE NAU ZU BERPR FEN UND D...
Page 60: ...ma LANILIA ul Mak w 10 38 500 Sanok Polska Poland Polen Tel 48 17 78 52 251 https lanilia com e mail office lanilia com Serwis Service Kundendienst Tel 48 17 78 52 251 Kom 48 609 055 660 e mail serwis...