background image

 

 

 

IPES/IES-5222T Series 

22 10/100TX + 2 1000T L2

+

 (w/8 PoE at/af) Industrial Managed 

Switch w/Enhanced G.8032 Ring 

 

 

User Manual (Hardware) 

 

   

     

 

 

                                                                     

IPES-5222T-8-67 

 

               

 

IES-5222T-67 

 

 

 

Dec.  2015 

Summary of Contents for IPES-5222T Series

Page 1: ...IPES IES 5222T Series 22 10 100TX 2 1000T L2 w 8 PoE at af Industrial Managed Switch w Enhanced G 8032 Ring User Manual Hardware IPES 5222T 8 67 IES 5222T 67 Dec 2015 ...

Page 2: ...oy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or wh...

Page 3: ...n consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does not include or infer any transfer of ownership Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules T...

Page 4: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipme...

Page 5: ...IP Protection 13 2 3 LED Indicators 16 Chapter 3 Hardware Installation 18 Chapter 4 Network Application 24 4 1 ITU G 8032 Scheme 24 4 2 Ring Coupling 24 4 3 Multiple Rings 25 4 4 Dual Homing 26 4 5 Chain 26 Chapter 5 Console Management 28 5 1 Connecting to the Console Port 28 5 2 Login in the Console Interface 28 ...

Page 6: ...l and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 1X User Authentication Radius IEEE802 1p Class of Service IEEE802 1Q VLAN Tag Switch Architecture Back plane Switching Fabric 8 4Gbps Packet through...

Page 7: ...0m Protocol CSMA CD Bypass Protection High speed optical switching 4ms Minimal insertion loss Max 1 6dB as Bypass Mode LED Per unit Power 1 Green Power 2 Green P Fail Red Ethernet port Link Activity Green Speed Green GigaT Link Activity Green DI DO 1 Digital Input DI Level 0 30 2V Level 1 10 30V Max input current 8mA 1 Digital Output DO Open collector to 40 VDC 200mA Operating Humidity 5 95 Non co...

Page 8: ...4 R25 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 2 Fire Smoke verification Warranty 5 years Future release Optional IPES 5222T 8 series Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE 802 3ab 1000BaseT IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1s Multiple Spanning Tree IEEE 802 3ad Lin...

Page 9: ...oded with auto MDI MDI X function RS 232 connector 1 x M12 5 pole A coded Power Input connector 1 x M23 5 pole A coded Relay contact 1 x M12 5 pole A coded Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Protocol CSMA CD PoE Budget 240W for 45 56V input 55V input is recommended for 802 3at 30W applicat...

Page 10: ...el 33 6 56VDC dual input 12V model 9 5 56VDC dual input 72V model 50 4 90VDC dual input Power Consumption Max 13W 12V 48VDC input Max 16W 72VDC Case Dimension IP67 Aluminum case 285mm W x201 4mm H x77 6mm D Weight 2 1kgs Installation DIN Rail and Wall Mount Design EMI EMS FCC Class A CE EN55022 Class A CE EN55024 CE EN61000 4 2 CE EN61000 4 3 CE EN61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE N61000 ...

Page 11: ...10 Future release Optional ...

Page 12: ... Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Aluminum case IP 67 285 W x 201 4 D x 84 4 H mm ...

Page 13: ...12 Port description of IP 67 series switch 2 2 Package Content Manual CD X1 Industrial Switch X1 Console cable X1 ...

Page 14: ...st access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and ingress of objects 1 50 mm Any large surface of the body such as the back of a hand but no protection against deliberate contact with a body part 2 12 5 mm Fingers or similar objects 3 2 5 mm Tools thi...

Page 15: ...to 15 from its normal position Test duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minutes Water volume 0 7 litres per minute Pressure 80 100 kPa 4 Splashing of water Water splashing against the enclosure from any direction shall have no harmful effect Te...

Page 16: ... 30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer Normally this will mean that the equipment is hermetically sealed However with certain types of equipment it can mean that water can e...

Page 17: ... not owner switch PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure P1 P8 Link Ack On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached PoE IPES model On The port is operating in PoE mode IPES model Off The port ...

Page 18: ...17 Off No device attached ...

Page 19: ...andard model The power input voltage can be from 9 5V to 60VDC 72V model The power input voltage can be from 50 4V to 90VDC 110V model The power input voltage can be from 43V to 137 5VDC PoE model 5 pin M23 connector Standard model The power input voltage can be from 33 6V to 56VDC to feed power on both the 802 3af and 802 3at standardized devices 12V model The power input voltage can be from 9 5V...

Page 20: ...or 802 3at operation with IPES 5222T 8 72V only 72VDC can power both the 802 3af and 802 3at PD The power consumption can satisfy the total power request from all PD devices required Non PoE model M12 PoE model M23 Pin assignment of Power input Dual Power Input The power input can be supported redundantly The supply voltage is electrically isolated from the housing Note With single power supply of...

Page 21: ...k status of at least one switch port 3 1 4 Fitting the device grounding Install the system in a dry and clean area to protect the switch to get exposed with dirt Plug the connector to the power supply plug then turn on the power supply Ground The chassis is grounded via a separate ground nut M3 Use toothed locking washers for a good electrical connection ...

Page 22: ...21 Ground screw of IPES 5408T switch 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding ...

Page 23: ...22 Pin assignment of M12 10 100Tx network connector Pin assignment of M12 10 100 100T network connector ...

Page 24: ... The protection class IP67 IP43 is only achieved when bolted together The other components attaching to the system have to meet with the IP67 IP43 protection class in order to reach the whole system IP 67 IP43 protection Empty ports must be sealed with the protective caps supplied ...

Page 25: ...mmunication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale 4 2 Ring Coupling ...

Page 26: ...25 4 3 Multiple Rings ...

Page 27: ...26 4 4 Dual Homing 4 5 Chain ...

Page 28: ...27 ...

Page 29: ...or to the console port of the switch The connected terminal or PC must support the terminal emulation program 5 2 Login in the Console Interface When the connection between Switch and PC is ready turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port Baud Rate 115200 bps Dat...

Page 30: ...pt appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html ...

Reviews: