____________________________________________________ _________________________________________________
LA-VST
(V.1.1 2011)
LA-VST
(V.1.1 2011)
CAUTION: NEVER connect a laser printer or scanner to the
UPS unit. This may cause the damage of the unit.
4 hours
1. Package Contents
You should have received the following items inside of package:
- UPS Unit
- Quick Guide
- USB Cable
- CD Software
- Power Cable (Only in LA-VST-1500/2000)
2. Product Overview
Front View:
LA-VST650/850 LA-VST-1000 LA-VST-1500/2000
X
Power Switch
[
Batt. Mode: yellow flashing
Y
UPS status LED
\
Fault LED: red lighting
AC Mode: green lighting
]
AC Mode: indicating load level
Batt. Mode: green flashing
Batt. Mode: indicating battery capacity
Z
AC Mode: green lighting
Back View:
LA-VST-650/850 LA-VST-1000 LA-VST-1500/2000
X
Output receptacles
[
USB port
Y
AC input
\
Modem/Phone surge protection
Z
Circuit breaker
3. Installation and Initial Startup
Line Interactive UPS LA-VST-650/850/1000/1500/2000
EN
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is
damaged.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow.
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT
operate the UPS where the temperature and humidity is outside the specific limits. (Please
check the specs for the limitations.)
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results,
suggest charging the battery at least 4 hours before initial use.
The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the
UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be
protected by UPS unit.
Connect Modem/Phone for Surge Protection
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the
UPS unit. Connect from “OUT” outlet to the computer with phone line cable.
Connect Communication Cable
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable one end to the USB port and the other to the communication port of
your PC. With the monitoring software installed, you can schedule UPS shutdown/start-up
and monitor UPS status through PC.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again
the power switch.