EPL-BS-70LED-6XMB-150X12
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
1
of
2
70 Watt Low Voltage Portable Explosion Proof LED Light
Magnetic Base - 150' SOOW Cord
Instruction Guide
Thank you for your purchase of the Larson Electronics EPL-BS-70LED series light. This light is completely assembled,
tested and ready for use when shipped from the factory. Please follow the steps below in order to operate and maintain
this product.
IMPORTANT
READ CAREFULLY BEFORE OPERATING THIS LIGHT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. IF UNSURE
ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICAL PROFESSIONAL. THE EPL-BS-70LED
MUST BE OPERATED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. PROPER
GROUNDING IS REQUIRED FOR SAFETY.
FOR PERSONAL SAFETY, ALWAYS CONFIRM THE RATING OF ANY KNOWN HAZARDOUS OR POTENTIALLY HAZARDOUS
LOCATION WHERE THE LIGHT IS TO BE USED.
WARNING:
OPERATE ONLY AT THE VOLTAGE LISTED ON THE PRODUCT LABEL.
WARNING:
TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, THE SUPPLY CIRCUIT SHOULD BE DISCONNECTED
WHEN INSTALLING OR PERFORMING ANY MAINTENANCE ON THIS UNIT.
WARNING:
WHEN INSTALLING THIS LIGHT IN HAZARDOUS LOCATIONS, CHECK THE OPERATING TEMPERATURE LIMITS
PRIOR
TO INSTALLATION TO BE SURE IT CONFIRMS TO THE ENVIRONMENTAL TEMPERATURE RESTRICTIONS AND NEC
CLASSIFICATIONS. CHECK THE FIXTURE’S METAL NAMEPLATE FOR TEMPERATURE (T) RATINGS.
WARNING:
DO NOT SCRATCH OR CHIP THE FRONT LENS. TURN THE POWER OFF BEFORE STARTING INSTALLATION OR
REPAIR.
WARNING:
OPERATE THIS FIXTURE ONLY AT THE VOLTAGE OF YOUR SPECIFIC SUPPLY CIRCUIT. FAILURE TO DO SO
WILL RESULT IN DAMAGE TO THE FIXTURE.
WARNING:
SUBSTITUTE COMPONENTS MAY IMPAIR EXPLOSION PROOF SAFETY.
INSTALLATION
Before operation, confirm that the power source will provide the
correct voltage indicated on the product nameplate. Ensure the
receptacle will accept the cord cap attached to the light.
Check product nameplate for Ratings and Approvals.
Place the light in the desired location and run its power cord to a
power source. Ensure all safety requirements are followed for the
hazardous area.
WARNING:
Transformer
MUST
remain
OUTSIDE
Hazardous Area!
This light is instant-on and will illuminate once energized.
Multi-voltage capability allows this light to be powered via
Voltage to Transformer: 110-277V AC 50/60Hz
ADJUSTMENT
Loosen the hand screw on side of the light to make vertical adjustments. Tighten hand screw once desired angle is
achieved.
The light can be mounted in any direction to a sturdy metallic surface. Ensure the mounting surface can withstand the
weight.
When removing, pull light straight off. Do not drag the magnets as this could scratch the surface light is mounted to.
Use the handle on top for easy maneuverability.