EPLC2-AMB-70LED-50
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
1
of
2
EPLC2-AMB-70LED-50 Instruction Guide
Explosion Proof 70W LED Light Fixture
Thank you for your purchase of the Larson Electronics EPLC2-AMB-70LED-50 Portable Explosion Proof LED
Light. Please follow the steps below in order to operate and maintain this product.
IMPORTANT
READ CAREFULLY BEFORE OPERATING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE EPLC2-AMB-70LED-50 MUST BE OPERATED IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
FOR PERSONAL SAFETY, ALWAYS CONFIRM THE RATING OF ANY KNOWN HAZARDOUS OR POTENTIALLY
HAZARDOUS LOCATION WHERE THE LIGHT IS TO BE USED.
WARNING:
TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, THE SUPPLY CIRCUIT SHOULD BE
DISCONNECTED WHEN INSTALLING OR PERFORMING ANY MAINTENANCE ON THIS UNIT.
WARNING:
WHEN INSTALLING THIS LIGHT IN HAZARDOUS LOCATIONS, CHECK THE OPERATING
TEMPERATURE LIMITS PRIOR TO INSTALLATION TO BE SURE IT CONFIRMS TO THE ENVIRONMENTAL
TEMPERATURE RESTRICTIONS AND NEC CLASSIFICATIONS. CHECK THE FIXTURE’S METAL NAMEPLATE FOR
TEMPERATURE (T) RATINGS.
WARNING:
DO NOT SCRATCH OR CHIP THE FRONT LENS. TURN THE POWER OFF BEFORE STARTING
INSTALLATION OR REPAIR.
WARNING:
OPERATE THIS FIXTURE ONLY AT THE VOLTAGE OF YOUR SPECIFIC SUPPLY CIRCUIT. FAILURE
TO DO SO WILL RESULT IN DAMAGE TO THE FIXTURE.
WARNING:
SUBSTITUTE COMPONENTS MAY IMPAIR EXPLOSION PROOF SAFETY.
•
PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE. ELECTROMAGNETIC
FIELDS IN CLOSE PROXIMITY TO HEART PACEMAKER COULD CAUSE PACEMAKER INTERFERENCE OR
PACEMAKER FAILURE.
•
KEEP FINGERS AWAY FROM MAGNET(S) WHEN MOUNTING AS INJURY COULD OCCUR.
OPERATING
Before operation, confirm that the power source will provide the correct voltage
indicated on the product nameplate. Ensure the receptacle will accept the cord cap
attached to the light.
Check product nameplate for Ratings and Approvals.
Affix light in the desired location and run its power cord to a compatible power source.
Mount light to a metal surface that can structurally support the load. Eight 100lb. grip
magnets hold the fixture in any position. The magnets are arranged in groups of two
and attached to the light via adjustable U-brackets, allowing operators to adjust the
magne
ts to match the curvature of tank walls or other curved surfaces. Simply loosen
the U-brackets, attach the magnetic mounting brackets to the desired surface, tighten
the magnetic brackets, then adjust the lamp assembly from the bracket. This bracket
system is constructed of non-sparking aluminum for light weight and durability, and the
simple swing hinge design allows operators to easily adjust the lamp assembly to
position the unit as a pedestal lamp if desired. Always ensure all safety requirements
are followed for the haza
rdous area.
Avoid excess tension between cord and light to reduce stress on the magnets. Mark
area as needed to avoid potential trip hazards or cable snags causing the light to
dismount.
The light head can be adjusted by loosening the screws on each side. Once loose, position the light head in