EPLC2-AMB-70LED-50 Instruction Guide

 

Explosion Proof 70W LED Light Fixture 

Thank you for your purchase of the Larson Electronics EPLC2-AMB-70LED-50 Portable Explosion Proof LED 
Light. Please follow the steps below in order to operate and maintain this product. 

IMPORTANT 

READ CAREFULLY BEFORE OPERATING  THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE 
REFERENCE. THE EPLC2-AMB-70LED-50 MUST BE OPERATED IN ACCORDANCE WITH NATIONAL ELECTRICAL 
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY. 

FOR PERSONAL SAFETY, ALWAYS CONFIRM THE RATING OF ANY KNOWN HAZARDOUS OR POTENTIALLY 
HAZARDOUS LOCATION WHERE THE LIGHT IS TO BE USED. 

 

WARNING:

  TO PREVENT IGNITION OF A HAZARDOUS ATMOSPHERE, THE SUPPLY CIRCUIT SHOULD BE 

DISCONNECTED WHEN INSTALLING OR PERFORMING ANY MAINTENANCE ON THIS UNIT. 

WARNING: 

WHEN INSTALLING THIS LIGHT  IN HAZARDOUS LOCATIONS, CHECK THE OPERATING 

TEMPERATURE LIMITS  PRIOR TO INSTALLATION TO BE SURE IT CONFIRMS TO THE ENVIRONMENTAL 
TEMPERATURE RESTRICTIONS AND NEC CLASSIFICATIONS. CHECK THE FIXTURE’S METAL NAMEPLATE FOR 
TEMPERATURE (T) RATINGS. 

WARNING: 

DO NOT SCRATCH OR CHIP  THE FRONT LENS. TURN THE POWER OFF BEFORE STARTING 

INSTALLATION OR REPAIR. 

WARNING: 

OPERATE THIS FIXTURE ONLY AT THE VOLTAGE OF YOUR SPECIFIC SUPPLY CIRCUIT. FAILURE 

TO DO SO WILL RESULT IN DAMAGE TO THE FIXTURE. 

WARNING: 

SUBSTITUTE COMPONENTS MAY IMPAIR EXPLOSION PROOF SAFETY. 

 

PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE. ELECTROMAGNETIC 
FIELDS IN CLOSE PROXIMITY TO HEART PACEMAKER COULD CAUSE PACEMAKER INTERFERENCE OR 
PACEMAKER FAILURE. 

 

KEEP FINGERS AWAY FROM MAGNET(S) WHEN MOUNTING AS INJURY COULD OCCUR. 

OPERATING 

Before  operation, confirm that the power source will provide the correct voltage 
indicated on the product nameplate. Ensure the receptacle will accept the cord cap 
attached to the light.  

Check product nameplate for Ratings and Approvals. 

Affix light in the desired location and run its power cord to a compatible power source. 
Mount light to a metal surface that can structurally support the load. Eight 100lb. grip 
magnets hold the fixture in any position. The magnets are arranged in groups of two 
and attached to the light via adjustable U-brackets, allowing operators to adjust the 
magne

 

ts to match the curvature of tank walls or other curved surfaces. Simply loosen 

the U-brackets, attach the magnetic mounting brackets to the desired surface, tighten 
the magnetic brackets, then adjust the lamp assembly from the  bracket.  This bracket 
system is constructed of non-sparking aluminum for light weight and durability, and the 
simple swing hinge design allows operators to easily adjust the lamp assembly to 
position the unit as a pedestal lamp if desired.  Always  ensure all safety requirements 
are followed for the haza

 

rdous area. 

Avoid excess tension between cord and light to reduce stress on the magnets. Mark 
area as needed to avoid potential trip hazards or cable snags causing the light to 
dismount. 

The light head can be adjusted by loosening the screws on each side. Once loose, position the light head in 