50W Tripod Mounted Food Safe LED Light 

Explosion Proof - C2D1 - 100' Cord - EXP Plug 

Instruction Manual

 

This explosion proof light tower is designed for illumination of industrial locations. It uses the 
latest in solid state lighting technology for long life, low maintenance and high efficiency. 

 

The unique design focuses the light where it is needed, giving improved efficiency over a 
conventional HID luminaire. 

 

An internal, universal input, power-factor-corrected switch-mode supply allows it to be used from any 

nominal 100-277V AC 50/60 Hz power supply without any variation in light output. 

 

WARNING 

To avoid the risk of fire, explosion or electric shock, this product should be installed, inspected 
and maintained by a qualified electrician only, in accordance with all applicable electrical codes. 

 

To avoid electric shock: 

 

 

Be certain electrical power is OFF before and during installation and maintenance. 

 

Luminaire must be connected to a wiring system with an equipment-grounding conductor. 

To avoid explosion: 

 

Make sure the supply voltage is within the luminaires’ voltage rating. 

 

Ensure the marked T rating is less than the ignition temperature of the Hazardous 
Atmosphere. 

 

Do not operate in ambient temperatures above those indicated on the luminaire nameplate. 

 

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated. 

 

For supply connections, use wire rated for at least 110°C 

 

 

TRIPOD ASSEMBLY 

The tripod assembly consists of 3 parts: 

1. 

Light head 

2. 

Pole w/Legs 

3. 

Wheel base 

To assemble tripod, begin by placing the legs over the wheel base. Tighten bolt to secure the wheels. 
The tripod can now be rolled around on its wheels. Ensure the legs are folded up before tilting tripod 
to maneuver.  

WARNING:

 

Use caution before tilting tripod with a heavy load. For heavy loads, it is recommended to 

remove the light head prior to transporting via wheel base! Failure to do so may cause serious injury 
or death. Larson Electronics shall not be held liable for injuries caused by misuse. 

1. 

Place tower in desired location that is flat and able to support the tripod without falling over. 