background image

L S I 005 -UK- REV. 04

I N S T R U C T I O N S   M A N U A L   F O R   T H E   I N S T A L L E R

Vivaldi

Vivaldi

Vivaldi

Summary of Contents for S1 Vivaldi

Page 1: ...LSI 005 UK REV 04 I N S T R U C T I O N S M A N U A L F O R T H E I N S T A L L E R Vivaldi Vivaldi Vivaldi ...

Page 2: ...EC 60335 2 75 IEC 60335 2 15 EC Declaration of Conformity to the Directive 97 23 EC Pressurised Equipment Directive PED MANUFACTURER La Spaziale SpA ADDRESS Via E Duse 8 Casalecchio di Reno BO ITALIA HEREBY DECLARES THAT On the espresso coffee machine S3 Via Spresso the pressure assembly is composed of a boiler complete with safety and adjustment devices used for rapid preparation of espresso coff...

Page 3: ... Optional page 10 3 1 VIEW OF PARTIAL AND TOTAL COFFEE COUNTERS 10 3 2 PARTIAL COFFEE COUNTER RESET 10 3 3 PROGRAMMING 11 Chap 4 LOCK TIMER MODULE Optional page 13 4 1 PROGRAMMING 13 4 2 LANGUAGE SETTING 14 4 3 CLOCK SETTING 14 4 4 ON OFF TIMER SETTING 15 Chap 5 ALARMS DESCRIPTION page 16 5 1 DAMAGED FLOWMETER 16 5 2 DAMAGED TEMPERATURE PROBE OF THE GROUP 16 5 3 DAMAGED TEMPERATURE PROBE OF THE BO...

Page 4: ...the packaging means that the product at the end of its lifetime must be disposed of separately from all the other waste The separate collection of this equipment coming at the end of its lifetime is organized and run by the importer distributor The user who should have to dispose of such equipment shouldgetintouchwiththeimporter distributorandfollowtheproceduretheyhaveadopted for the separate disp...

Page 5: ...e machine should not be enclosed The machine needs to be installed so that the disconnection plug from the electric main source remains accessible If in doubt regarding the above mentioned important requirements with reference to the system arranged by the customer please consult qualified staff The appliance is not supposed to operate in the external environment that is to say directly subject to...

Page 6: ... water inlet pipe in order to prevent impurities from damaging the motor pump or the machine 1 7 WATER MAINS INSTALLATION SCHEME 1 3 2 3 LEGEND Water tap prearranged by the customer Water softener optional Flexible pipes resisting high pressure provided with the machine 1 6 ELECTRIC INSTALLATION SCHEME 1 LEGEND Main switch prearranged by the customer When carrying out the electric connections plea...

Page 7: ...sure of 9 Bar 2 2 HOW TO ADJUST THE OPERATING TEMPERATURE OF S1 VIVALDI 1 While the appliance is operating press and hold down the ON OFF button 27 for about 3 seconds the line control light 22 and the set temperature led will flash For example if the set temperature is 105 C the led 18 will flash LIGHT No 13 14 15 16 17 18 19 20 21 22 TEMP 85 90 95 100 105 110 120 130 C 2 To change the operating ...

Page 8: ...rature will increase by 1 C each time the button is pressed and the relevant led will switch on and flash At the maximum temperature of 97 C led 20 the selection will start again from the minimum temperature of 91 C led 14 cyclical function 3 Once the required temperature has been selected press the ON OFF 27 button to confirm the setting the appliance will return to normal operation To set a deli...

Page 9: ... 10 placing two cups below the filterholder 9 Press the two coffees button 25 to start delivery and the lights 17 18 19 will switch on to show that the two coffee dose is being programmed 10 When the coffee inside the cup has reached the desired quantity press again the button 25 to stop the delivery 11 You automatically return to the initial visualization N B Once you have entered the programming...

Page 10: ...ed and the display shows the main screen as illustrated here below 01927 Number of cups of coffee that can still be delivered 02000 Number of pre set deliveries 3 1 VIEW OF PARTIAL AND TOTAL COFFEE COUNTERS Pressing the key during normal operation the display will show P 00286 shows the partial number of coffee deliveries made since the last reset the partial is the sum of 1 cup and 2 cup coffee d...

Page 11: ...e one to the right of the previously set digit which will start to flash To set the next digits proceed in the same way and after confirming the last digit of the PIN if correct the programming mode will open If the PIN is not correct it will return to the first zero on the left flashing To quit without setting the PIN wait 10 seconds to return to the main screen N B The default PIN is 1234 When t...

Page 12: ...amming mode will open moving with the keys the letter Y will start to flash and when the OK key is pressed to confirm the available doses and those stored to memory will be deleted before returning to the main screen If the letter N is confirmed from the screen for setting the COFFEE No the display will read with the letter N flashing press the OK key to confirm this setting to quit the programmin...

Page 13: ...iale for 3 seconds followed by the software version and then the current time and date If the timer is set alternatively to the date it is possible to see the time that the appliance will next switch on if it is switched off ON 14 30 or the time that the appliance will next switch off if it is on OFF 21 30 N B This only happens if the operations will occur before midnight of the current day If the...

Page 14: ...of the week Monday will flash Pressing the buttons will select the current day of the week and the OK button will confirm the selection at this point the display will read The month January will flash Pressing the buttons will select the current month and the OK button will confirm the selection at this point the display will read The date 30 will flash Pressing the buttons will select the current...

Page 15: ... on and off by timer the display will read The day of the week will flash pressing the buttons will scroll through the days of the week confirm the day to be set in this case Monday using the OK button and the display will show the switch on time for that day The two digits for the time 07 will flash pressing the buttons selects the time and to confirm press the OK button The minutes 35 will autom...

Page 16: ...utton for 3 seconds to copy all of the settings and the display will move to the next day Repeat the operations until the day in which different timer settings are required The day will flash press the OK button to set the times as described here above for Monday N B To leave the machine on for more than one day it is necessary to set the OFF time for the selected day and the ON time for the next ...

Page 17: ...n short circuit temperature above 145 C or is interrupted temperature inferior to 60 C The lights 19 20 21 turn on To eliminate the visualization deacivate the boiler pressing the button 26 and the machine can keep working even without the boiler being on If this alarm is visualized check the connections of the temperature probe to the control board or replace the probe 5 4 DAMAGED HEATING ELEMENT...

Page 18: ...EV 04 DIAGRAMS 6 1 ELECTRIC DIAGRAM 6 CONTROL BOARD GND 230 V 115 V SB 1 4 1 2 S2 1 4 F SER 1 SER 2 TOUCHPAD 1 2 1 2 TSC TRIAK GROUP 1 2 1 2 TRIAK BOILER TSB S1 1 2 JP3 JP4 SD SE 1 4 EXTERNAL DISPLAY 1 4 PHASE NEUTRUM E V GR RC E V H RB E V AL MP FUSE 5A ...

Page 19: ...RAM 6 4 LED CIRCUIT DIAGRAM 6 3 TRIAK DIAGRAM M1 P1 V M3 F1 F1 R3 R2 U1 R1 F1 in F1 out M2 M1 P2 M3 F1 F1 R3 R2 U1 1 3 R1 F2 in F2 out M2 M1 SER 2 1 3 F DISPLAY SE T2 SER1 PUMP PHASE EV GR EV H NEUTRUM NEUTRUM F2 F1 xxx F3 JP3 M1 M7 M3 JP4 T5A FUSE M3 M2 S2 P2 T1 M8 S1 SL EV A L SD ...

Page 20: ...ion control board on control panel Flowmeter Phase inlet into the triak feeding the boiler heating element Phase outlet from the triak feeding the boiler heating element Phase inlet into the triak feeding the group heating element Phase outlet from the triak feeding the group heating element Boiler temperature probe Brewing group temperature probe Boiler water level control Ventilator connection M...

Page 21: ...E V A P E U R V A POR STEA M D A M P F 24 23 25 26 27 8 12 16 6 5 7 8 9 2 4 3 11 1 10 12 28 13 14 15 16 17 18 19 20 21 22 8 12 8 12 16 29 4 24 23 25 26 27 13 14 15 16 17 18 19 20 21 22 91 92 93 94 95 96 97 II Vivaldi Vivaldi Vivaldi Vivaldi Vivaldi Vivaldi II Vivaldi Vivaldi Vivaldi ...

Page 22: ...DI II version 16 Water temperature led for coffee 95 C 93 C on the VIVALDI II version 17 Water temperature led for coffee 100 C 94 C on the VIVALDI II version 18 Water temperature led for coffee 105 C 95 C on the VIVALDI II version 19 Water temperature led for coffee 110 C 96 C on the VIVALDI II version 20 Water temperature led for coffee 120 C 97 C on the VIVALDI II version 21 Economy mode contro...

Page 23: ...INSTRUCTIONS MANUAL FOR THE INSTALLER LSI 005 UK REV 04 23 05 2009 Graphics and Printing X TYPE ENGINEERING S r l for LA SPAZIALE S p A ...

Page 24: ...La Spaziale S p A Via E Duse 8 40033 Casalecchio di Reno Bologna Italy Tel 39 051 611 10 11 Fax 39 051 611 10 40 E mail info laspaziale com Web Site www laspaziale com ...