background image

1  Closer handed at factory and must match hand of door.

Hand of closer stamped on finish plate.

2 Voltage shown on box label must match voltage sup-

plied to door frame.

3  If door & frame are not prepared for closer & track,

prepare according to details on opposite side.

4  A. Remove finish plate and wiring cover from closer.

B. Assemble flexible conduit connector to conduit

mounting bracket.

C. Connect input voltage to plug leads as shown in

wiring diagram at bottom left.

D. Replace wiring cover.

E. Insert closer into frame and secure with proper

screws.

F. Replace finish plates.

5. Insert track roller into track. Insert track in door cut out

and secure with proper screws.

6. Place arm on closer shaft and secure with shaft screw.

7. Loosen set screw in end of arm, open door part way

(about 30°), pull arm over top of door and connect to

track roller. Tighten set screw firmly.

8.

Do not allow door to slam into frame. A "normal" closing time from 90°

open position is 5 to 7 seconds. Use socket screw key furnished.

To slow MAIN SPEED of door, turn regulation

screw (nearest arm) clockwise. To show

LATCH SPEED of door, turn regulating

screw (nearest latch) clockwise.

REGULATION

BACKCHECK

To increase BACKCHECK, turn regulating

screw (nearest hinge) clockwise.

Using lightest BACKCHECK that will retard

door opening sufficiently.

9

Adjust CLOSING POWER only if more power is needed.

Closer is shipped with minimum closing power pre-set. To

increase CLOSING POWER turn spring adjusting screw

clockwise. Maximum adjustment of 18 turns.

CLOSING POWER

DO NOT USE AN ABPURT BACKCHECK

NOR EXPECT DOOR CLOSER TO ACT AS DOOR STOP

11

HOLDING FORCE ADJUSTMENT

IF DOOR IS HARD TO PULL OUT OF HOLD OPEN,

ADJUST AS SHOWN.

Holding Force is at maximum. This can be decreased and

increased again but not increased beyond original setting.

IMPROPER INSTALLATION OR

REGULATION MAY RESULT IN

PERSONAL INJURY OR

PROPERTY DAMAGE. FOLLOW ALL

INSTRUCTIONS CAREFULLY. FOR

QUESTIONS, CALL LCN AT

800 - 526 - 2400

CAUTION

!

2310-ME

INSTRUCTION SHEET

IF CLOSER HAS OPTIONAL HOLD-OPEN BYPASS FEATURE, BYPASS LABEL WILL BE ON CYLINDER

02/08                                                                                       © 2008 SCHLAGE LOCK Company. All rights reserved.

DP # 19911R4

WIRING DIAGRAM

INPUT VOLTAGE

12V AC/DC

24 AC/DC

OR

120V AC/DC

(USUALLY FROM

ALARM PANEL

OR DETECTOR)

A.

B. If not, push on/off switch.

C. If door does not stay open, verify electrical input in wiring diagram at right.

D. Turn power off, door should close completely.

E. To release hold open manually, pull door firmly. Door should close completely

under power of closer.

F. System should be checked at regular intervals. It is suggested that steps A & D

be repeated every 90 days.

With power on, open the door any position and release. The door should remain

in the hold-open position within 10°. For a bypass model to hold open, the door

must be opened beyond degree of door swing indicated on label.

10

ELECTRICAL CHECKOUT

1-800-526-2400

®