background image

 

 

 

LDP1000 

 

Gas Purifier for noble gases and nitrogen 

 
 
 
 
 
 
 

USER’S MANUAL 

V1.0 

 
 
 
 
 
 

Printed in Canada 

Copyright 2010 

Summary of Contents for LDP1000

Page 1: ...LDP1000 Gas Purifier for noble gases and nitrogen USER S MANUAL V1 0 Printed in Canada Copyright 2010...

Page 2: ...ent 1 Forwarning 2 2 Warranty maintenance and service policies 3 3 Specifications 6 4 Cautions and installation information 6 4 1 Gas line connection 6 4 2 Installation steps 6 5 Lifetime and LED indi...

Page 3: ...tek makes assumption that all operators have taken the time to read this information prior to install operate and troubleshoot the purifier If any error is suspected by the reader please contact LDete...

Page 4: ...r the loss or damage directly or indirectly arising from the use of the equipment of goods from breach of any warranty or from any other cause All other warranties expressed or implied are hereby excl...

Page 5: ...VERED BY UMBRELLA INSURANCE AND OR INDEMNITY COVERAGE PROVIDED TO BUYER ITS ASSIGNS AND EACH SUCCESSOR INTEREST TO THE GOODS PROVIDED HERE UNDER Major force Seller is not liable for failure to perform...

Page 6: ...tions may apply to international shipments PROPRIETARY RIGHTS Buyer agrees that any LDetek s software firmware and hardware products ordered or included in the goods ordered are proprietary of LDetek...

Page 7: ...tion Maximum 200 watts Dimensions 12 304 8 high 4 12 104 mm deep 4 25 108 mm wide Weight 5 lbs 2 26 kg 4 Cautions and installation information 4 1 Gas line connection Be sure to connect the upcoming g...

Page 8: ...make sure you have the right operating voltage 7 With the power on the purifier let the gas vent to the atmosphere for about 3 hours 5 Lifetime and LED indication The LDP1000 getter has a lifetime of...

Page 9: ...nual 8 6 Drawings Wiring Diagram Cable 4 Cable 5 Cable 2 Cable 3 RS 232 Connector Cable 1 Thermocouple 1 Thermocouple 2 Yellow Led Green Led Red Led Heater 1 Heater 2 Pin A Corcom Pin C Module Pin B P...

Page 10: ...he lifetime is over Getter replacement procedure Step 1 Turn off the power on the LDP1000 unit Step 2 Remove the inlet and outlet tubing connections Step 3 Step 4 Remove the front part of the LDP1000...

Page 11: ...power up the unit for normal operation running NOTE MAKE SURE TO WELL PURGED THE LINE BEFORE TO CONNECT TO THE INLET 10 MINUTES PURGE DO NOT EXPOSE THE DEVICE TO AIR MAKE SURE TO QUICKLY CONNECT INLET...

Page 12: ...LDP1000 User s manual 11...

Reviews: