background image

www.lemaitrefx.com

Neutron XS

Operations Manual

v.01.03.01

Summary of Contents for Neutron XS Hazer

Page 1: ...www lemaitrefx com Neutron XS Operations Manual v 01 03 01 ...

Page 2: ...roduction Page 2 Warning Page 3 Technical Specifications Page 4 Operating Procedure Page 5 Remote and External Control Features Page 7 Maintenance Page 10 Recommended Fluids Page 10 Warranty Page 11 Safety Precautions Page 12 Accessories Page 13 Notes Table of Contents ...

Page 3: ...y silent operation with instant effect The haze is generated without the use of oil eliminating any residue associated with cracked oil effects Silent operation combined with continuous output optional DMX and remote control places the Neutron XS in a class of its own Features Introduction Whisper Quiet Operation Continuous Haze Output 1 Gallon of fluid lasts 160 Hours Micro Processor Controlled D...

Page 4: ...sthma or allergenic sensitivity may experience irritation discomfort or allergic symptoms when exposed to heated fog effects IMPORTANT SAFETY INSTRUCTIONS Do not touch or place hands expose skin within 10 cm of discharge nozzle SAVE THESE INSTRUCTIONS READ THESE IMPORTANT SAFETY INSTRUCTIONS WARNING Ensure that this unit is grounded at all times Failure to do so may result in serious injury WARNIN...

Page 5: ...eutron XS Hazer with S T A R Technology Type Water Base Haze Generating System Dimensions Length 67 cm 11 25 Width 28 5 cm 9 Height 33 cm 10 94 Weight with Fluid 11 Kg 23 75 lbs Power Rating 115VAC 60HZ 3 15A 220VAC 50HZ 1 45A Neutron XS Illustration 3 ...

Page 6: ...machine into a suitable main power supply Set the Mains switch to the On position located on the rear panel The Mains switch will illuminate to indicate the presence of Mains power A clean power supply is essential to the operation of the Neutron For this reason we do not recommend the supply of mains power from a lighting dimmer 3 Set the Haze switch to the On position located on the rear panel T...

Page 7: ...tron XS is primed haze vapour will automatically be issued in a cycling fashion When the unit is operating normally the LED will flash in pulses 6 To stop haze issue set the Haze switch to the Off position The Neutron XS will not immediately stop issuing haze but will enter into an additional auto cleanse phase After this period the Neutron XS will shut down and the Monitor led will stop flashing ...

Page 8: ...minated as long as the Neutron Remote is receiv ing power it does not duplicate the flashing of the Monitor Led 6 Start haze output by selecting On at the Haze switch on the Neutron Remote Pinout for 3 Pin XLR Pin 1 Remote Signal Pin 2 GND Pin 3 12V The D M X Interface Part CLF 3320 will allow D M X 512 Protocol to activate the Haze output of the Neutron XS Haze machine See the publication include...

Page 9: ...ower Down procedure MUST be followed each time the power to the Neutron XS is turned off 1 Turn the Haze switch to the OFF position to initiate the cleansing cycle 2 The cleansing cycle will begin clearing the processing coil of unprocessed fluids The monitor light will continue to flash until the cleansing cycle has ended at which time the monitor light will go out 3 The Mains power switch can no...

Page 10: ...ed in this kit are extra abrazors cleaning solution and a spare Processing Tube To order this kit use Part CXP 2486 Warning Make certain the power cord is unplugged when servicing this unit Failure to disconnect may result in fatal electric shock fire or injury to persons To avoid possible burns allow sufficient time for the unit to cool 1 Disconnect power by unplugging unit from main power sup pl...

Page 11: ...ce port into the processing coil with an in and out motion The burrs on the Abrazor will de scale the walls resulting in a rejuvenated processing tube For a better grip on the Abrazor tool a few turns of electrical tape gives a better grip of the cleaning tool 6 The unit is now ready to reassemble Take note of the alignment studs when assembling the lid Tighten knob fasteners 7 The maintenance is ...

Page 12: ...or proof of sale must always accompany any warranty returns An RA return authorization number must be noted on the outside of any box returned to our facilities Any packages without a clearly marked RA number will not be accepted by our receiving department Proper maintenance and shut down procedure must be followed to ensure Hazing performance Should your Hazing Element Tube become plugged a clea...

Page 13: ...se in the application it was intended Le Maitre Special Effects takes no responsibility for misuse or incorrect use Always refer to equipment owners manual for proper use Safety Precautions 1 Ensure that operation of the machine is supervised by suitably trained and authorised personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow sufficient air circulatio...

Page 14: ...hands or exposed skin within the first 10cm of the discharge nozzle at any time during haze production Accessories Listed below are accessories available for your Neutron XS through your Le Maitre dealer 12 Model Description CLF 2415 Neutron Pro Remote CLF 3320 DMX Interface CLF 2420 Neutron Road Case CXP 2485 Replacement XS Hazer Coil CLF 2421 Neutron Hang nging B ng Bracket CXP 2486 Neutron XS C...

Page 15: ...www lemaitrefx com Notes 13 ...

Reviews: