background image

 
 
 

 
 
 
 
 
 
 

 

 

 

Bypass Door Window Sensor Z-Wave

TM

 700

 

7AA-SS-VE-C0 

 
 
 
 
 
 
 

Bypass Door Window Sensor 
Quick Start Guide 

 

Summary of Contents for 7AA-SS-VE-C0

Page 1: ...Bypass Door Window Sensor Z WaveTM 700 7AA SS VE C0 Bypass Door Window Sensor Quick Start Guide ...

Page 2: ...lets you know when door or windows is opened and can trigger different actions in response to that open action or close action Detection Technology Hall Detective Range 20mm Communication Protocol Z Wave Radio Frequency 908 42MHz US 868 42MHz EU Wireless Range More than 200m outdoors Approximately 30m indoors depending on building materials Power Source 3V CR2 1 Battery Life 3 years Mounting Screw...

Page 3: ...battery cabinet Use a pin to reset the pinhole switch for 5 seconds to reset the sensor The sensor will be in pairing status Stick the slim magnet and device onto the door window no further than 20 mm from the sensor fix the device on the door window by screw or 3M tape The magnet and the main sensor must be less than 20 mm apart Main sensor must be affixed to the frame and the magnet must be affi...

Page 4: ... t know how to do this refer to its manual DSK usually print on the main body 2 Remove the battery from the Door Sensor A few seconds later reinsert battery in the DUT 3 The Door Sensor will send Z Wave protocol Command Class frameto start SmartStart Inclusion 4 LED will flash green during the inclusion and then solid green for 2 seconds to indicate that the inclusionis successful otherwise the LE...

Page 5: ...sending data Not on the network NOP Press and hold Z B utton more than 5 seconds Reset Door Sensor to factory default LED will blink red faster and faster within 5 seconds and then keep solid red until the button is released Device will reset itself to factory default by sending a Device Reset Locally Notification to gateway when the button is released Short press the Bypass Button Only on the net...

Page 6: ...ble harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environment safe recycling 7 Maintenance If need to clean the sensor please use a soft...

Page 7: ...uthority to operate the equipment Hereby Corporation declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU Special Rule Of Each Command Class Z Wave Plus Info Report Command Class Parameter Value Z Wave Plus Version 0x02 Role Type 0x06 ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPOR TING Node Type 0x00 ZWAVEPLUS_INFO_R...

Page 8: ... pressed 7 Device Reset Locally Z Button is press and hold for more than 5 seconds Group 2 0x05 1 Basic Set Sensor will send Basic Set when the sensor body and magnet removed or combined Association Group Info Command Class Association Group Info Grouping identifier Group Name Profile MS Profile LS 01 Lifeline 0x00 0x01 02 On Off control 0x71 0x06 Association Group Command List Group 1 Command Lis...

Page 9: ...s Home Security Tampering_Covering_Removed 0x03 the tamper button back the main body is released Previous Events cleared 0x00 the tamper button back the main body is pressed Access Control Door is open 0x16 the separation of the main body and the magnet Door is closed 0x17 the combination of the main body and the magnet Power Management REPLACE_BATTERY_SOON 0x0A When the Door Sensor first time det...

Page 10: ...ue Manufacturer ID 1 0x03 Manufacturer ID 2 0x00 Product Type ID 1 0x03 Product Type ID 2 0x00 Product ID 1 0x00 Product ID 2 0x41 5 6 Configuration Set Command Class 5 6 1 Command Format 7 6 5 4 3 2 1 0 Command Class COMMAND_CLASS_CONFIGURATION Command CONFIGURATION_SET Parameter Number Default Reserved Size Configuration Value 1 MSB Configuration Value 2 5 7 Central Scene 8 bit Configuration Val...

Page 11: ...erage magnetic field in ut Range 0x00000001 0x00004B00 or 0x00000001 0x0002EE00 640 4 0x03 7210PolHyst Set the offset about magnetic field Range 0x00000001 0x00002300 or 0x00000001 0x00015E00 200 4 0x0A LowBatPrecent This parameter defines a battery level as the low battery Range 0x05 0x32 10 1 0x0E BasicEnable Enable Disable BASIC SET command 0 Disable 1 Enable 0 1 0x0F BasicReverse Door Sensor r...

Page 12: ... 5 1 No read onl y Unsigne d integer true BasicEnable SendBasic 0x0E 0 1 0 1 No read onl y Unsigne d integer true BasicReverse BasicValue 0x0F 0 1 0 1 No read onl y Unsigne d integer true Bypass BypassSet 0x20 0 1 0 1 No read onl y Unsigne d integer true temp TemperatureInf o 0x21 15 255 15 1 No read onl y Unsigne d integer true LockConfig LockConfigSet 0xFE 0 1 0 1 No read onl y Unsigne d integer...