INSTRUCTION / INSTALLATION SHEET

Selective Call Intercom Patio Unit 

 

IS-0388 Rev. B

 
301Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com 

©Copyright 2011 by Legrand All Rights Reserved. 

Page 1 of 3 

 

1. Introduction  

 

The Legrand Selective Call Intercom Patio Unit, PN IC5004-XX (see

 

Figure 1

),

 

is weather resistant for outdoor use, and supports responding 

to a selective call, initiating a page within the house, local control of the 
mute and monitor functions and the ability to talk to a Door Unit. A 
separate high quality speaker and microphone provide superior sound 
quality. It is available in white (-WH), shiny brass (-SB), antique brass (-
AB), brushed stainless (-BS) and oil-rubbed bronze (-OB). 

 
 

2. Description  

 

The Patio Unit is a 2-gang product that mounts within an outdoor 
weatherproof box (56” from the floor to the bottom of the box). There is 
also a two-gang surface-mount box available (P/N IC5006-BK) for unique 
or retrofit installation requirements. 

 

 

3. Installation  

 

Installation of the Selective Call Patio Unit is best accomplished at multiple times during new construction, at 
“Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and painted

 

A.   “Rough-in” steps: 
  

1.  Run a Cat 5 cable from the Enclosure where the Selective Call Intercom Module will be installed to the 

2 gang box at the Selective Call Patio Unit location. 

 

NOTE: The maximum Cat 5 cable run distance between the SCI Module and another unit (Module, 
Door, Patio or Room Unit) is 330’ with the following exception. One Door or Patio Unit may be placed 
up to 1000’ (up to 650’ for a Video Door Unit) from the SCI Module, but it needs to be locally powered 
and Legrand needs to be informed of and pre-approve this type of installation. If the Cat 5 run is 
buried in an underground conduit, it should maintain a 16” separation from any 110VAC wiring. 
Additional SCI Modules are recommended to be placed in the same enclosure, powered from the 
same power strip, and interconnected with the shortest Cat 5 connections possible.

  

NOTE: It is important to keep all in-wall Category 5e cable runs at least 12 inches away from AC 
electrical cables. If it proves necessary to cross an existing AC cable, do so only at a 90 degree angle. 

 
B. “Trim-out” 

steps: 

 

NOTE: All terminations can be correctly completed by following the T568A pin assignments. It is 
important that you accurately terminate using T568A at all locations. All terminations of the Selective Call 
Intercom System are RJ45 jacks. Refer to 

Figure 2

 for correct T568A termination of RJ45 plugs. 

 
 
 
 
 
 
 
 

Figure 1 

RJ-45

Pin

1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown

RJ-45

Pin

1 – White/Green
2 – Green
3 – White Orange
4 – Blue
5 – White/Blue
6 – Orange
7 – White/Brown
8 – Brown

Figure 2 