www.kenall.com | P: 800-4-Kenall | F: 262-891-9701 | 10200 55th Street Kenosha, Wisconsin 53144, USA
This product complies with the Buy American Act: manufactured in the United State swith more than 50% of the component cost of US origin It may be covered by patents
found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. ©2019 Kenall Mfg.Co.
1
INSTALLATION INSTRUCTIONS
F-2189
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED. FOLLOW ANY SPECIFIC
INSTRUCTIONS ON LUMINAIRE LABELS.
Preparation
•
Read all fixture markings and labels to
insure correct installation of the fixture.
Additional information may be located on
the fixture or in supplemental instructions
sheets, separate from this instruction sheet,
regarding orientation,mounting restrictions
and optional equipment.
• For Peace of Mind Warranty, fixture must be
mounted to building with at least 4 fasteners
(4 point mounting). Attachment to the
electrical box only is NOT recommended.
• WARNING: Disconnect power to the circuit
before wiring fixture.
• Minimum 12” supply wire pigtails
must extend from electrical junction box
for field connections within fixture enclosure.
APPLICATIONS
MILLENIUM METREX
™
METEL SERIES
• Drilling Tip: Drill small pilot holes from
inside, using drill points as guides. Enlarge
holes from outside, using spade bits and
light pressure to reduce “digging in” and
slow drill speed to prevent material
overheating. Remove burrs and plastic
chips from parts prior to assembly.
WALL MOUNTING (Fig.1): Remove SHIELD
and STENCIL ASSEMBLY. RemoveELECTRICA
L CHASSIS by disengaging tabs in upper corners.
Remove REFLECTOR (if provided). Locate
appropriate REAR PANEL drillpoints and drill (4)
5/16” dia. mounting holes and (1) hole of
suitable size for supply wire entry. Place
HOUSING over an installed electrical
junction box (drill points provided for temporary
j-box attachment prior to permanent mounting).
Locate and drill 4 pilot holes in mounting surface
using REAR PANEL as a template. For wet
location installation, attach self-adhesive pad
GASKET to REAR PANEL. Using 1/4-20 fasteners
and anchors appropriate for the mounting
surface (not supplied), attach HOUSING
to structure.
IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
• DO NOT USE OUTDOORS.
• DO NOT MOUNT NEAR GAS OR ELECTRIC HEATERS.
• EQUIPMENT SHOULD BE MOUNTED IN LOCATIONS AND AT HEIGHTS WHERE
IT WILL NOT BE SUBJECTED TO TAMPERING BY UNAUTHORIZED PERSONNEL.
• THE USE OF ACCESSORY EQUIPMENT NOT RECOMMENDED BY THE
MANUFACTURER MAY CAUSE AN UNSAFE CONDITION.
• DO NOT USE THIS EQUIPMENT FOR OTHER THAN ITS INTENDED USE.
When using electrical equipment, basic safety precautions should always be followed, including the following:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH
THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS
BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO
AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE.
SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING
ORIENTATION, OR MOUNTING RESTRICTIONS.
SAVE THESE INSTRUCTIONS