background image

Contents Page

General description / Technical data / Safety instructions 

 ............................................. 2

Care and maintenance / Factory settings / Functional description

 ................................. 3

Overview of transponder cards ...

 ................................................................................... 4

System components / Package contents / Installation

 .................................................... 5

Installation variant for internal RFID reader .

 .................................................................. 6

Dimensions

 ...................................................................................................................... 8

Getting started and changing batteries / Tips for programming steps ..

 ......................... 9

Using the installation card / Programming the master card

 .......................................... 10

Programming the user cards / Closing & opening

 ......................................................... 11

Unauthorised transponder cards / Facility Manager function / Emergency opening

 ... 12

Deleting individual transponder cards / Deleting all transponder cards

 ....................... 13

Changing the operating mode

 ....................................................................................... 14

Deactivating and activating acoustic signals / Resetting to factory settings

 .................. 15

Configure RFID system with LEGIC System Authorization Media (SAM)

 ....................... 16

Remove LEGIC MTSC configuration on RFID system / Battery warning 

 ........................ 17

External power supply / Firmware update

 .................................................................... 18

Reordering master cards

 ............................................................................................... 19 

Troubleshooting

 ............................................................................................................ 20

www.lehmann-locks.com

Operating instructions

GB

M300 LEGIC L043-A01 / -A02

BD

A M300 L043-A01 / -A02 2020-05-25 (GB)

L043-A02

L043-A01

Summary of Contents for M300 LEGIC L043-A01

Page 1: ...ards Closing opening 11 Unauthorised transponder cards Facility Manager function Emergency opening 12 Deleting individual transponder cards Deleting all transponder cards 13 Changing the operating mode 14 Deactivating and activating acoustic signals Resetting to factory settings 15 Configure RFID system with LEGIC System Authorization Media SAM 16 Remove LEGIC MTSC configuration on RFID system Bat...

Page 2: ...e locking system can be configured with master and programming cards or with the LEHMANN Management Software LMS These operating instructions describe how to use the locking system with master and programming cards The software LMS and the corresponding documents can be found at https lms lehmann locks com TECHNICAL SPECIFICATIONS SAFETY PRECAUTIONS U U When replacing the batteries make sure that ...

Page 3: ...EGIC System Authorization Media SAM see Configure RFID System with LEGIC System Authorization Media SAM P 16 LEGIC prime transponders are only supported in the mode assigned use without LEGIC stamp on the RFID system Only the M300 LEGIC L043 A02 with a spacer is suitable for use on metallic surfaces Please note that the distance between two or more RFID readers must be at least 5 cm This system is...

Page 4: ...he first time the lock is disabled for the installation card The use of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode The master card also enables the so called Facil...

Page 5: ...w 3x13 for E Box 4 3x batteries 1 5V AA 5 Cover for E Box 6 1x screw 3x13 for cover 7 Cable Optional components for RFID reader L043 A01 8 RFID reader L043 A01 9 2x thermoplastic screw 3x20 10 RFID reader housing for internal mounting 11 2x screw 3x13 for RFID reader housing 12 Double sided adhesive tape Optional components for RFID reader L043 A02 13 RFID reader L043 A02 14 2x thermoplastic screw...

Page 6: ...etween the transponder card and the RFID reader is then limited and light signals are no longer visible Please also note that an external power supply is only possible with an external RFID reader Please note the different mounting positions and drilling pattern for the RFID readers CAUTION For mounting the RFID reader L043 A02 without spacer please use drill holes of 5 5mm with spacer please use ...

Page 7: ...BDA M300 L043 A01 A02 2020 05 25 GB 7 Internal mounting of M300 and RFID reader L043 A01 1 2 3x30 6 4 5 7 8 3 3x13 Door ...

Page 8: ...the two housing screws by hand and then connect the optical cable to the lock 5 Remove the protective film from the rear side of the adhesive tape Then stick the entire reading unit to the inner side of the door Please position the RFID reader in such a way that you still have access to the micro USB port DIMENSIONS M300 4 5 1 2 3 RFID reader L043 A01 RFID reader L043 A02 RFID reader L043 A02 with...

Page 9: ... the lock in accordance with these operating instructions Once the programming operation is completed ensure that the system is functioning correctly CAUTION Use only LR6 AA alkaline type batteries Rechargeable batteries zinc carbon batteries or lithium batteries are not permitted TIPS FOR THE FOLLOWING PROGRAMMING STEPS The last 5 seconds before the shutdown of the programming process are announc...

Page 10: ...HE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed after the master card has been programmed the next step must be an emergency opening s...

Page 11: ...e user cards see Closing and Opening P 10 After programming the user cards can open and close the lock Programming user cards Master Hold the master card in front of the reader User Hold the user card in front of the reader The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Master Hold the master card in front of the reader CLOSING ...

Page 12: ...ock opens for 30 seconds and then closes automatically After this automatic closure authorised user cards can continue to be used in Shared use mode as well as in Assigned use mode EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note that the lock remains open after emergency opening I...

Page 13: ...ser cards Master Hold the master card in front of the reader User Hold the user card to be deleted in front of the reader Master Hold the master card in front of the reader DELETING ALL TRANSPONDER CARDS only for Assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master ca...

Page 14: ...st be bought separately from LEHMANN Vertriebs gesellschaft mbH Co KG The cards are for universal use Changing the operating mode Master Hold the master card in front of the reader P1 Mode Hold the programming card No 1 P1 Mode in front of the reader Shared use mode is selected Shared use P1 Mode Hold the programming card No 1 P1 Mode in front of the reader again Assigned use mode is selected Assi...

Page 15: ...are for universal use Deactivating and activating acoustic signals Master Hold the master card in front of the reader P2 Sound Hold the programming card No 2 P2 Sound in front of the reader The acoustic signals are deactivated Acoustic signals are deactivated P2 Sound Hold the programming card No 2 P2 Sound in front of the reader again Acoustic signals are activated again Acoustic signals are acti...

Page 16: ...RE RFID SYSTEM WITH LEGIC SYSTEM AUTHORIZATION MEDIA SAM Special permissions and configurations are transferred to the RFID reader by using the SAM 63 card that is part of the LEGIC Master Token System Control MTSC Following this only LEGIC advant transponders or user cards with the associated digital stamp can be used on the RFID readers Master and programming cards are still usable The lock must...

Page 17: ...onders mentioned on page 2 under technical specifications can be used again The lock must be open when using the SAM 64 card Remove configuration with LEGIC SAM 64 card Master Hold the master card in front of the reader SAM 64 Hold the LEGIC SAM 64 card in front of the reader Master Hold the master card in front of the reader Master Hold the master card in front of the reader If the lock is in del...

Page 18: ...use a standard power bank additional rechargeable battery with a USB port complying with the USB 2 0 standard A micro USB Type B connector is required for the emergency power supply of the RFID reader Use the emergency power supply only for a short period of time for the one off opening of a lock Before use it is essential that you should read the operating instructions of the power bank Please pr...

Page 19: ... the firmware are described in the software RFID reader L043 A01 Micro USB port for emergency power supply and firmware updates RFID reader L043 A02 REORDERING MASTER CARDS With this locking system you have the option of ordering replacements for your master cards at your own expense For this you obtained a service key together with the master cards Please keep the service key carefully and secu r...

Page 20: ...end position Possible reasons Striker plate or lock not correctly installed Furniture door is not closed The bolt is being blocked by an object Battery warning Phase 1 It is recommended that you replace the batteries Battery warning Phase 2 The batteries must be replaced without delay Communication error between the RFID reader and the lock Possible reason Connecting cable between the lock and the...

Page 21: ...ck the functions open close with an authorised user card again when the furniture is open If the lock should work properly please check to see if the bolt can extend correctly when the furniture is closed see installation recommendation If you are using an existing user card not from the Lehmann company check to see whether the appropriate write permission has been given for the transponder card L...

Page 22: ...A01 A02 2020 05 25 GB 22 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2008 zertifiziert ...

Reviews: