Contents Page

General Description / Technical Specifications / Safety Precautions ............................... 2
Care and Maintenance / Factory Settings / Functional Descrition .................................. 3
Overview of Transponder Cards ...................................................................................... 4
System Components / Package Contents / Installation ................................................... 5
Dimensions ...................................................................................................................... 7
Getting Started and Changing Batteries / Tips for Programming .................................... 8
Using the Installation Card / Programming the Master Card .......................................... 9
Programming the User Cards / Closing and Opening  ................................................... 10
Unauthorised Transponder Cards / Facility Manager Function /  

Emergency Opening  ..................................................................................................... 11
Deleting Individual Transponder Cards / Deleting all Transponder Cards ..................... 12
Changing the Operating Mode / Deactivating and Activating Acoustic Signals  ............ 13
Resetting to Factory Settings ......................................................................................... 14
Configure RFID system with LEGIC System Authorization Media (SAM) ....................... 15
Remove LEGIC MTSC configuration on RFID system / Battery Warning ........................ 16
Emergency Power Supply / Firmware Update ............................................................... 17
Reordering Master Cards /Troubleshooting .................................................................. 18

www.lehmann-locks.com

Operating Instructions

GB

Locker Lock  

M610 LEGIC L043-A03

BD

A M610 LE

GIC L043-A03 2022-07-12 (GB)

Summary of Contents for M610 L043-A03

Page 1: ...ing 10 Unauthorised Transponder Cards Facility Manager Function Emergency Opening 11 Deleting Individual Transponder Cards Deleting all Transponder Cards 12 Changing the Operating Mode Deactivating and Activating Acoustic Signals 13 Resetting to Factory Settings 14 Configure RFID system with LEGIC System Authorization Media SAM 15 Remove LEGIC MTSC configuration on RFID system Battery Warning 16 E...

Page 2: ...agement Software LMS These operating instructions describe how to use the locking system with master and programming cards The software LMS and the corresponding documents can be found at https lms lehmann locks com TECHNICAL SPECIFICATIONS SAFETY PRECAUTIONS U When replacing the batteries make sure that the polarity and position of the batteries are correct U Dispose of used batteries properly U ...

Page 3: ...em must be confi gured with LEGIC System Authorization Media SAM see Configure RFID System with LEGIC System Authorization Media SAM P 15 LEGIC prime transponders are only supported in the assigned use mode without LEGIC stamp on the RFID system Only the M610 LEGIC L043 A03 with a spacer is suitable for use on metallic surfaces Please note that the distance between two or more RFID readers must be...

Page 4: ...y After a master card has been programmed for the first time the lock is disabled for the installation card The use of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode T...

Page 5: ... screws for mounting the lock and the RFID reader must be adapted Components for M610 1 M610 2 4x screw 4 5x16 for M610 3 2x battery CR123A 4 Cover for M610 5 Striker plate 6 3 x flat headed screws 3 0 x 15 mm for striker plate only included in single set packaging 7 Pin for battery compartment Components for RFID reader L043 A03 8 Cabel 9 RFID reader L043 A03 10 2x thermoplastic screw 3x20 11 Spa...

Page 6: ...door surface except Omega profiles The locker lock M610 is available in two versions right or left mounting Please ensure the correct installation position of the lock and the RFID reader Tighten the screws hand tight with max 0 7 Nm Please note the different mounting positions and drilling pattern for the RFID readers M610 RFID reader L043 A03 with spacer 18 5 5 5 5 7 7 32 32 70 20 RFID reader L0...

Page 7: ... reader L043 A03 with spacer 6 8 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 6 8 14 4 4 22 14 6 27 39 1 15 5 4 5 44 10 Striker plate 105 94 94 105 14 25 27 5 5 4 9 4 5 25 8 5 5 2 ø 28 5 14 5 2 ø 29 5 64 76 14 14 8 5 5 2 ø 28 5 14 5 2 ø 29 5 64 76 14 14 5 2 28 5 14 75 64 5 2 29 5 76 14 64 ...

Page 8: ...ment and wait until a long acoustic signal and at the same time an optical signal yellow are given Close the cover of the battery compartment Press the cover until it snaps into all four latch positions Then program the lock in accordance with these operating instructions B Inserting the batteries Batteries are inserted correctly in the battery compartment Initialisation takes place During initia ...

Page 9: ...HE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed after the master card has been programmed the next step must be an emergency opening s...

Page 10: ...he user cards see Closing and Opening P 10 After programming the user cards can open and close the lock Programming user cards Master Hold the master card in front of the reader User Hold the user card in front of the reader The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Master Hold the master card in front of the reader CLOSING...

Page 11: ...lock opens for 30 seconds and then closes automatically After this automatic closure authorised user cards can continue to be used in Shared use mode as well as in Assigned use mode EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note that the lock remains open after emergency opening ...

Page 12: ...Master Hold the master card in front of the reader User Hold the user card to be deleted in front of the reader Master Hold the master card in front of the reader DELETING ALL TRANSPONDER CARDS only for Assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deletin...

Page 13: ... P1 Mode in front of the reader Shared use mode is selected Shared use P1 Mode Hold the programming card No 1 P1 Mode in front of the reader again Assigned use mode is selected Assigned use Master Hold the master card in front of the reader DEACTIVATING AND ACTIVATING ACOUSTIC SIGNALS Acoustic signalling is activated when the system is delivered You have the option of deactivating the acoustic sig...

Page 14: ... use Resetting to factory settings Master Hold the master card in front of the reader Please note that the acoustic signals for the battery warning and for changing the operating mode cannot be deactivated The programming card set must be bought separately from LEHMANN Vertriebsgesellschaft mbH Co KG The cards are for universal use Deactivating and activating acoustic signals Master Hold the maste...

Page 15: ... card that is part of the LEGIC Master Token System Control MTSC Following this only LEGIC advant transponders or user cards with the associated digital stamp can be used on the RFID readers Master and programming cards are still usable The lock must be open in order to program the SAM 63 card Detailed information about the LEGIC MTSC is available at www legic com Configuration with LEGIC SAM 63 c...

Page 16: ...he reader SAM 64 Hold the LEGIC SAM 64 card in front of the reader Master Hold the master card in front of the reader BATTERY WARNING The locking system is equipped with a battery management system which uses visual and acoustic signals to indicate the need for battery replacement in the event of reduced battery power The battery warning takes place in two phases Battery warning Phase 1 Before an ...

Page 17: ...nnect the charged power bank to the RFID reader using the micro USB port U Please take account of the operating instructions of the power bank e g for starting and ending the charging process U Please do not perform any further actions until the RFID reader gives an acoustic and a visual signal see Acoustic and visual signals when inserting the batteries U Then open the lock with an authorised tra...

Page 18: ...e Transponder card cannot be programmed Possible reasons Storage space is used up Card is not compatible Master card has not yet been programmed Available storage space in the lock is used up Possible reasons 50 user cards have already been programmed in the lock Bolt warning the bolt does not move to the end position Possible reasons Striker plate or lock not correctly installed Furniture door is...

Page 19: ...eck the functions open close with an authorised user card again when the furniture is open If the lock should work properly please check to see if the bolt can extend correctly when the furniture is closed see installation recommendation If you are using an existing user card not from the Lehmann company check to see whether the appropriate write permission has been given for the transponder card ...

Page 20: ...L043 A03 2022 07 12 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2008 zertifiziert ...