background image

Lenovo System x3550 M5 (Machine Type 8869)

Product Guide

Designed in a compact, versatile 1U two-socket rack server, the Lenovo System x3550 M5 (E5-2600 v4)

server (Machine Type 8869) fuels almost any workload in the software-defined data center from infrastructure

to high-performance computing (HPC) to cloud or big data with leadership security, efficiency, and reliability

features. With support for Intel Xeon processor E5-2600 v4 product family and faster, energy-efficient

TruDDR4 memory, the System x3550 M5 delivers exceptional performance. Flexible and scalable internal

storage configurations include up to 12x 2.5-inch or 4x 3.5-inch drives with a wide selection of drive sizes and

types.

Suggested use: Database, virtualization and cloud computing, infrastructure security, systems management,

enterprise applications, collaboration/email, streaming media, web, and HPC.

The following figure shows the System x3550 M5.

Figure 1. Lenovo System x3550 M5

Did you know?

The System x3550 M5 incorporates energy smart features for minimized costs and efficient performance. Dual

fan zones support operation in up to 40°C environments. 80 PLUS Titanium power supply units (PSUs) can

deliver 96% efficiency at 50% load.

The System x3550 M5 has outstanding memory performance that is achieved by supporting two-RDIMM-per-

channel configurations at speeds up to 12% faster than the Intel specification, while still maintaining world-

class reliability.

The System x3550 M5 integrates leadership security and reliability. System x Trusted Platform Assurance, an

exclusive set of System x features and practices, establishes a solid security foundation for your workloads.

Enterprise-class data protection is provided with optional self-encrypting drives, and advanced diagnostic

tools facilitate reduced downtime and costs.

Lenovo System x3550 M5 (Machine Type 8869)

1

Summary of Contents for 8869

Page 1: ...collaboration email streaming media web and HPC The following figure shows the System x3550 M5 Figure 1 Lenovo System x3550 M5 Did you know The System x3550 M5 incorporates energy smart features for minimized costs and efficient performance Dual fan zones support operation in up to 40 C environments 80 PLUS Titanium power supply units PSUs can deliver 96 efficiency at 50 load The System x3550 M5 h...

Page 2: ...ond processor thermal design power TDP Intel Hyper Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads Note Also...

Page 3: ...tems Analysis DSA Preboot speed up troubleshooting to reduce service time Manageability and security Powerful systems management features simplify local and remote management of the System x3550 M5 and deliver enterprise class data protection The server includes an Integrated Management Module II IMM2 1 to monitor server availability and perform remote management An integrated industry standard Un...

Page 4: ...r uses hexagonal ventilation holes a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system Lenovo XClarity Energy Manager provide advanced data center power notification analysis and policy based management to help achieve lower heat output and reduced cooling needs Components and connectors T...

Page 5: ...ced optional The following figure shows the front of the System x3550 M5 server with ten 2 5 inch drive bays Figure 5 Front view of the System x3550 M5 10x 2 5 inch drive bays The following figure shows the front of the System x3550 M5 server with eight 2 5 inch SAS SATA and two 2 5 inch PCIe drive bays Figure 6 Front view of the System x3550 M5 8x 2 5 inch SAS SATA 2x PCIe drive bays Lenovo Syste...

Page 6: ...our 3 5 inch drive bays Figure 7 Front view of the System x3550 M5 4x 3 5 inch drive bays The following figure shows the rear of the System x3550 M5 server with three PCIe low profile slots Figure 8 Rear view of the System x3550 M5 Lenovo System x3550 M5 Machine Type 8869 6 ...

Page 7: ...The following figure shows the locations of key components inside the server Figure 9 Internal view of the System x3550 M5 Lenovo System x3550 M5 Machine Type 8869 7 ...

Page 8: ...SD non hot swap front drive bays Up to 8x 2 5 SAS SATA hot swap drive bays 4x 2 5 front 4x 2 5 front 4x 3 5 SAS SATA hot swap drive bays front Maximum internal storage Up to 92 TB with 12x 7 68 TB 2 5 SAS SSDs Up to 40 TB with 4x 10 TB 3 5 NL SAS or NL SATA HDDs Up to 24 TB with 12x 2 TB 2 5 NL SATA HDDs Up to 28 8 TB with 12x 2 4 TB 2 5 SAS HDDs Up to 7 68 TB with 2x 3 84 TB NVMe PCIe SSDs Interm...

Page 9: ... power supplies or 900 W High Efficiency 48 V DC power supplies Hot swap parts Hard drives power supplies and fans Systems management Unified Extensible Firmware Interface UEFI Integrated Management Module II IMM2 1 based on Renesas SH7758 Predictive Failure Analysis light path diagnostics Automatic Server Restart ToolsCenter XClarity Administrator and XClarity Energy Manager Optional IMM2 1 Advan...

Page 10: ...50W HS 2 8869Q2x 1x E5 2667 v4 8C 3 2GHz 25MB 2400MHz 135W 1x 16GB M5210 2GB F 4x 2 5 HS 8 Open bay 4x GbE 2 4 Option Included 1x 750W HS 2 8869L2x 1x E5 2690 v4 14C 2 6GHz 35MB 2400MHz 135W 1x 16GB M5210 2GB F 4x 2 5 HS 8 Open bay 4x GbE 2 4 Option Option 1x 750W HS 2 8869N2x 1x E5 2697 v4 18C 2 3GHz 45MB 2400MHz 145W 1x 16GB M5210 2GB F 4x 2 5 HS 8 Open bay 4x GbE 2 4 Option Included 1x 900W HS ...

Page 11: ...3U 2x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 2x 16GB M5210 4x 2 5 HS 8 Open bay 4x GbE 1 4 Option Option 2x 900W HS 2 8869KGU 1x E5 2630 v4 10C 2 2GHz 25MB 2133MHz 85W 1x 16GB M5210 4x 2 5 HS 8 Open bay 4x GbE 1 4 Option Option 1x 900W HS 2 8869KHU 1x E5 2630 v4 10C 2 2GHz 25MB 2133MHz 85W 1x 16GB M5210 4x 3 5 HS 4 Open bay 4x GbE 1 4 Option None 1x 900W HS 2 8869KYU 1x E5 2630 v4 10C 2 2GHz 25MB 2...

Page 12: ...6GB M5210 4x 2 5 HS 8 Open bay 4x GbE 1 4 Option Option 1x 750W HS 2 8869EAG 1x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 1x 16GB M5210 4x 3 5 HS 4 Open bay 4x GbE 1 4 Option None 1x 750W HS 2 8869ENG 1x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 1x 8GB M5210 1GB F 8x 2 5 HS 8 Open bay 4x GbE 1 4 Option Option 1x 550W HS 2 8869E3G 1x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 1x 16GB M5210 2GB F 8x 2 5 HS 8 Ope...

Page 13: ...GbE 2 4 Option Option 1x 750W HS 2 886916F 1x E5 2620 v4 8C 2 1GHz 20MB 2133MHz 85W 1x 16GB M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Multi burner Included 1x 750W HS 2 886916G 1x E5 2640 v4 10C 2 4GHz 25MB 2133MHz 90W 1x 16GB M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Multi burner Included 1x 750W HS 2 886916H 1x E5 2650 v4 12C 2 2GHz 30MB 2400MHz 105W 1x 16GB M5210 4x 2 5 HS 8 Open bay 4x GbE 2 4 Multi b...

Page 14: ...135 W Yes Yes Yes Yes E5 2640 v4 2 4 3 4 GHz 10 20 25 MB 2133 MHz 8 0 GT s 90 W Yes Yes Yes Yes E5 2643 v4 3 4 3 7 GHz 6 12 20 MB 2400 MHz 9 6 GT s 135 W Yes Yes Yes Yes E5 2648L v4 1 8 2 5 GHz 14 28 35 MB 2400 MHz 9 6 GT s 75 W Yes Yes Yes Yes E5 2650 v4 2 2 2 9 GHz 12 24 30 MB 2400 MHz 9 6 GT s 105 W Yes Yes Yes Yes E5 2650L v4 1 7 2 5 GHz 14 28 35 MB 2400 MHz 9 6 GT s 65 W Yes Yes Yes Yes E5 26...

Page 15: ...r E5 2603 v4 6C 1 7GHz 15MB Cache 1866MHz 85W 00YE893 ATLT ATMH Intel Xeon Processor E5 2608L v4 8C 1 6GHz 20MB Cache 1866MHz 50W 00YJ695 ATMC ATN3 Intel Xeon Processor E5 2609 v4 8C 1 7GHz 20MB Cache 1866MHz 85W 00YE894 ATLU ATMJ Intel Xeon Processor E5 2618L v4 10C 2 2GHz 25MB Cache 2133MHz 75W 00YJ696 ATMD ATN4 Intel Xeon Processor E5 2620 v4 8C 2 1GHz 20MB Cache 2133MHz 85W 00YE895 ATLV ATMK I...

Page 16: ...W 00KA076 A5BM A5C1 Intel Xeon Processor E5 2697 v3 14C 2 6GHz 35MB 2133MHz 145W 00MU404 ASCQ ASD1 Description Part number Feature codes The first feature code is for the first processor the second feature code is for the second processor Memory The System x3550 M5 supports TruDDR4 memory TruDDR4 memory uses the highest quality components sourced from Tier 1 DRAM suppliers and only memory that mee...

Page 17: ...esigns that support memory speeds beyond Intel memory specifications which provides benefits for workloads that require memory speed and density System x TruDDR4 memory is fully supported up to the speeds that are shown in the following tables Table cells highlighted with a gray background indicate when the DIMMs are allowed to operate at a higher speed than Intel specifications define Table 7 Sys...

Page 18: ...Hz LP LRDIMM 46W0841 ATGG 12 24 One processor two processors Not supported with the Intel Xeon processor E5 2600 v3 product family Internal storage The System x3550 M5 server supports the following internal drive bay configurations 1 4x 2 5 inch SAS SATA hot swap drive bay server models that can be upgraded to 8x 2 5 inch SAS SATA hot swap drive bays 2 10x 2 5 inch SAS SATA hot swap drive bay serv...

Page 19: ...5 front IO cage Advanced 00MV368 ATLK 1 The following table shows the internal storage options available for the System x3550 M5 server Table 10 Internal storage options Description Part number Feature code Maximum supported Base drive kits System x3550 M5 4x 2 5 HS HDD Kit None A59W 1 System x3550 M5 4x 3 5 HS HDD Kit None A5A4 1 System x3550 M5 10x 2 5 HS HDD Kit None A5A0 1 System x3550 M5 NVMe...

Page 20: ...led 1x System x3550 M5 10x 2 5 HS HDD Kit FC A5A0 and 1x System x3550 M5 2x 2 5 HS HDD Rear Kit FC A5A2 Field upgrade for the 10 drive bay model 1x System x3550 M5 2x 2 5 HS HDD Rear Kit PN 00KA058 4x 3 5 inch SAS SATA hot swap 1x RAID or HBA Factory installed 1x System x3550 M5 4x 3 5 HS HDD Kit FC A5A4 In the Storage controller column RAID or HBA means any supported controller for internal stora...

Page 21: ...ID M5200 Series SSD Caching Enabler 47C8712 A3Z8 1 Features on Demand upgrades for the M1215 system wide ServeRAID M1200 Zero Cache RAID 5 Upgrade 00AE930 A5H5 1 PCIe extenders for NVMe PCIe SSDs System x NVMe PCIe SSD Extender Adapter 00ML997 AS95 1 2 Requires cache memory upgrade 47C8656 47C8660 47C8664 or 47C8668 One FoD upgrade enables the feature on all ServeRAID M5200 Series adapters M5210 M...

Page 22: ...e controllers drive types and internal drive bays Drive bays Storage Controller Drive type SAS HDD NL SAS HDD NL SATA HDD SAS SED SAS SSD SATA SSD PCIe SSD Front drive bays 4 8 10x 2 5 inch SAS SATA hot swap front M1215 Yes Yes Yes Yes Yes Yes No M5210 Yes Yes Yes Yes Yes Yes No N2215 Yes Yes Yes No Yes Yes No 4x 3 5 inch SAS SATA hot swap front M1215 Yes Yes Yes No No Yes No M5210 Yes Yes Yes No ...

Page 23: ... 2TB 7 2K 6Gbps NL SATA 2 5 G3HS 512e HDD 00NA526 AT81 12 2 5 inch hot swap SEDs 12 Gbps SAS 300GB 10K 12Gbps SAS 2 5 G3HS SED 00WG705 AT8D 12 600GB 10K 12Gbps SAS 2 5 G3HS SED 00WG710 AT8E 12 900GB 10K 12Gbps SAS 2 5 G3HS SED 00WG715 AT8F 12 1 2TB 10K 12Gbps SAS 2 5 G3HS SED 00WG720 AT8G 12 2 5 inch hot swap SEDs 12 Gbps NL SAS 2TB 7 2K 12Gbps NL SAS 2 5 G3HS 512e FIPS 140 2 SED 01GR670 AUCF 12 2...

Page 24: ...e Mainstream SATA G3HS 2 5 SSD 01GV848 AXFW 12 5100 960GB Enterprise Mainstream SATA G3HS 2 5 SSD 01GV853 AXFX 12 5100 1 92TB Enterprise Mainstream SATA G3HS 2 5 SSD 01GV858 AXFY 12 5100 3 84TB Enterprise Mainstream SATA G3HS 2 5 SSD 01GV863 AXFZ 12 2 5 inch hot swap SSDs S3610 Enterprise Mainstream 6 Gbps SATA Intel S3610 480GB Enterprise Mainstream SATA G3HS 2 5 SSD 00YK212 AU3C 12 Intel S3610 8...

Page 25: ...ATA G3HS 2 5 SSD 01GR841 AVHQ 12 PM863a 960GB Enterprise Entry SATA G3HS 2 5 SSD 01GR846 AVHR 12 2 5 inch hot swap SSDs Enterprise Value 6 Gbps SATA 120GB SATA 2 5 MLC G3HS Enterprise Value SSD 00AJ395 A577 12 240GB SATA 2 5 MLC G3HS Enterprise Value SSD 00AJ400 A578 12 480GB SATA 2 5 MLC G3HS Enterprise Value SSD 00AJ405 A579 12 800GB SATA 2 5 MLC G3HS Enterprise Value SSD 00AJ410 A57A 12 2 5 inc...

Page 26: ...6Gbps NL SATA 3 5 G2HS 512e HDD 00FN143 A5VH 4 6TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00FN173 A5VM 4 8TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00WH126 ATRT 4 10TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 00YK341 AU7S 4 3 5 inch hot swap SEDs 12 Gbps NL SAS 2TB 7 2K 12Gbps NL SAS 3 5 G2HS 512e FIPS 140 2 SED 01GR676 AUCM 4 4TB 7 2K 12Gbps NL SAS 3 5 G2HS FIPS 140 2 SED 01GR682 AUCN 4 6TB 7 2K 12Gbps N...

Page 27: ...HT 4 PM863a 960GB Enterprise Entry SATA HS 3 5 SSD 01GR856 AVHU 4 3 5 inch hot swap SSDs S3520 Enterprise Entry 6 Gbps SATA Intel S3520 240GB Enterprise Entry SATA HS 3 5 SSD 01GR741 AUF0 4 Intel S3520 480GB Enterprise Entry SATA HS 3 5 SSD 01GR746 AUF1 4 Intel S3520 800GB Enterprise Entry SATA HS 3 5 SSD 01KR471 AXGC 4 Intel S3520 960GB Enterprise Entry SATA HS 3 5 SSD 01GR751 AUF2 4 Intel S3520 ...

Page 28: ...ported external optical drive can be used instead Server models with up to 8x 2 5 inch drive bays require the Front IO cage Standard 00MV367 or Advanced 00MV368 for optical drive support Ultraslim 9 5mm SATA DVD ROM part number 00AM066 supports the following media and speeds for reading CD ROM 24X CD DA DAE 24X CD R 24X CD RW 24X DVD ROM 8X DVD R 8X DVD R 8X DVD R DL 6X DVD R DL 8X DVD RW 8X DVD R...

Page 29: ...troller The locations of the PCIe slots are shown in the following figure Figure 12 PCIe slot locations Riser 1 supplies slot 1 and Riser 2 supplies slots 2 and 3 The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed One or two processors and no riser cards Slot 4 is available for use One or two processors and one ...

Page 30: ...ected the x16 Riser 1 option feature code A5AG cannot be used If both ML2 Riser 1 feature code A5AH and FHHL x8 or x16 Riser 2 option feature code A5AE or A5AD are selected one of the following ML2 network adapters is allowed for selection Broadcom NetXtreme II ML2 Dual Port 10GbaseT part number 00D2026 Broadcom NetXtreme II ML2 Dual Port 10GbE SFP part number 00D2028 Emulex VFA5 ML2 Dual Port 10G...

Page 31: ...frames up to 9600 bytes Optionally the System x3550 M5 server supports ML2 adapters that are installed in the custom ML2 slot provided by the PCIe ML2 riser card part number 00KA063 This slot supports adapters with either two or four 10 Gb ports or four Gigabit ports and supports direct connectivity to the IMM2 1 service processor for out of band systems management The following table lists additi...

Page 32: ...and FCoE iSCSI SW 00AG580 AT7T 3 1 2 3 Intel X520 Dual Port 10GbE SFP Adapter 49Y7960 A2EC 3 1 2 3 Intel X540 T2 Dual Port 10GBaseT Adapter 49Y7970 A2ED 3 1 2 3 Intel X550 T1 Single Port 10GBase T Adapter 00MM850 ATRY 3 1 2 3 Intel X550 T2 Dual Port 10GBase T Adapter 00MM860 ATPX 3 1 2 3 Intel X710 DA2 2x10GbE SFP Adapter 01DA900 AU2Y 3 1 2 3 Mellanox ConnectX 3 10 GbE Adapter 00D9690 A3PM 3 1 2 3...

Page 33: ...ers Cables for Mellanox FDR InfiniBand QSFP adapters Transceivers and cables for 100 GbE QSFP28 network adapters Cables for Mellanox EDR InfiniBand QSFP28 adapters Cables for Intel Omni Path QSFP28 adapters The following table lists transceivers and cables for the 10 GbE SFP adapters Table 21 Transceivers and cables for 10 GbE SFP adapters Description Part number Feature code 10 GbE SFP SR transce...

Page 34: ... 00VX005 AT2V Passive copper cables for 40 GbE QSFP network adapters Lenovo 1m Passive QSFP DAC Cable 49Y7890 A1DP Lenovo 3m Passive QSFP DAC Cable 49Y7891 A1DQ The following table lists cables for the Mellanox FDR InfiniBand QSFP adapters Table 24 Cables for Mellanox FDR InfiniBand QSFP adapters Description Part number Feature code Passive copper cables for Mellanox FDR InfiniBand QSFP adapters 0...

Page 35: ...AC Cable 7Z57A03565 AV23 Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable 7Z57A03566 AV24 Active optical cables for 100 GbE QSFP28 network adapters Lenovo 3m 100G QSFP28 Active Optical Cable 7Z57A03546 AV1L Lenovo 5m 100G QSFP28 Active Optical Cable 7Z57A03547 AV1M Lenovo 10m 100G QSFP28 Active Optical Cable 7Z57A03548 AV1N Lenovo 15m 100G QSFP28 Active Optical Cable 7Z57A03549 AV1P Lenovo ...

Page 36: ...e 00WE051 AU0K 3m Intel OPA 100 Series Passive Copper QSFP28 Cable 00WE055 AU0L Active optical cables for Intel Omni Path QSFP28 adapters 5m Intel OPA 100 Series Active Optical QSFP28 Cable 00WE059 AU0M 10m Intel OPA 100 Series Active Optical QSFP28 Cable 00WE063 AU0N 15m Intel OPA 100 Series Active Optical QSFP28 Cable 00WE067 AU0P 20m Intel OPA 100 Series Active Optical QSFP28 Cable 00WE071 AU0Q...

Page 37: ...8 LSI SAS3008 Host interface PCIe 3 0 x8 PCIe 3 0 x8 Port interface 12 Gbps SAS 12 Gbps SAS Number of external ports 8 8 External port connectors 2x Mini SAS HD SFF 8644 2x Mini SAS HD SFF 8644 Drive interface SAS SATA SAS SATA Drive type HDD SED SSD HDD SSD Maximum number of devices 240 1024 RAID levels 0 1 10 5 50 Optional 6 60 PN 47C8706 None JBOD mode No Yes Cache 2 GB included None Cache prot...

Page 38: ... 3 QLogic 16Gb Enhanced Gen5 FC Single port HBA 01CV750 ATZB 3 1 2 3 QLogic 16Gb FC Single port HBA 00Y3337 A3KW 3 1 2 3 QLogic 16Gb Enhanced Gen5 FC Dual port HBA 01CV760 ATZC 3 1 2 3 QLogic 16Gb FC Dual port HBA 00Y3341 A3KX 3 1 2 3 8 Gb Fibre Channel PCIe Emulex 8Gb FC Single port HBA 42D0485 3580 3 1 2 3 Emulex 8Gb FC Dual port HBA 42D0494 3581 3 1 2 3 QLogic 8Gb FC Single port HBA 42D0501 357...

Page 39: ...3 Not supported with the Intel Xeon processor E5 2600 v3 product family Supported only in the PCIe slot 2 and requires the FHHL x16 Riser Card 2 feature code A5AD and the second processor or the FHHL x8 Riser Card 2 feature code A5AE Configuration notes The Flash Adapters might require the use of the additional system fans see Cooling for details Low profile Flash Adapters are supported in low pro...

Page 40: ...ers 01GT711 00YA812 and 00YA815 The following table lists the additional system fan option for the System x3550 M5 The option contains two additional fans Table 33 Additional system fans Description Part number Feature code Maximum supported x3550 M5 Fan Gen 2 00MV373 ATL1 1 Power supplies and cables The System x3550 M5 server supports up to two redundant power supplies and is capable of N N redun...

Page 41: ...e 6400 2 8m 10A 100 250V C13 to IEC 320 C20 Rack Power Cable 39Y7938 6204 4 3m 10A 100 250V C13 to IEC 320 C14 Rack Power Cable 39Y7932 6263 Country specific line cords Argentina 10A 250V C13 to IRAM 2073 2 8m line cord 39Y7930 6222 Australia NZ 10A 250V C13 to AS NZ 3112 2 8m line cord 39Y7924 6211 Brazil 10A 125V C13 to 2P Gnd 1 8m line cord None 6599 Brazil 10A 250V C13 to 2P Gnd 1 8m line cord...

Page 42: ...ity is handled internally by the SD Media Adapter The following table lists virtualization options Table 36 Virtualization options Description Part number Feature code Maximum supported USB memory key USB Memory Key for VMware ESXi 5 1 Update 2 00ML233 ASN6 1 USB Memory Key for VMware ESXi 5 5 Update 2 00ML235 ASN7 1 USB Memory Key for VMware ESXi 5 5 Update 3B 00WH150 ATZG 1 USB Memory Key 4G for...

Page 43: ...crosoft Windows Server 2016 Microsoft Windows Server 2012 R2 Microsoft Windows Server 2012 Red Hat Red Hat Enterprise Linux 7 3 Red Hat Enterprise Linux 7 2 Red Hat Enterprise Linux 6 8 Server x64 Edition Red Hat Enterprise Linux 6 7 Server x64 Edition SUSE SUSE Linux Enterprise Server 12 SP2 SUSE Linux Enterprise Server with Xen 12 SP2 SUSE Linux Enterprise Server 12 SP1 SUSE Linux Enterprise Ser...

Page 44: ...ontents before the IMM2 1 restarts the server when the IMM2 1 detects an operating system hang condition A system administrator can use the blue screen capture to assist in determining the cause of the hang condition The following table lists the remote management option Table 37 Remote management option Description Part number Feature code Maximum supported Integrated Management Module Advanced U...

Page 45: ...ized systems management solution that helps administrators deliver infrastructure faster This solution integrates easily with Lenovo x86 servers Flex System and RackSwitch switches providing automated agent less discovery monitoring firmware updates configuration management and bare metal deployment of operating systems and hypervisors across multiple systems Lenovo XClarity Administrator is an op...

Page 46: ... should be ordered Lenovo XClarity Integrator for Microsoft System Center Lenovo XClarity Integrator for VMware vCenter Lenovo XClarity Integrators allow administrators to manage physical infrastructure from leading external virtualization management software tools from Microsoft and VMware Lenovo XClarity Integrators offer the following additional features Ability to discover manage and monitor L...

Page 47: ... North America AP Asia Pacific EMEA Europe Middle East Africa LA Latin America Rack installation The following table lists the rack installation options that are available for the System x3550 M5 server Table 41 Rack installation options Description Part number Feature code Maximum supported 4 post rail kits System x3550 M5 Non ball Bearing Slide 00MV369 ATL0 1 System x3550 M5 Slide Kit G4 00KA606...

Page 48: ...e of the front mounting flange to the rear most point of the rail Note The System x3550 M5 Slide Kit G4 00KA606 is included with the models that are listed in Standard models and TopSeller models Physical specifications The System x3550 M5 server has the following dimensions and weight approximate Height 43 mm 1 7 in Width 434 mm 17 1 in Depth 734 mm 28 9 in Weight Minimum configuration 13 8 kg 30...

Page 49: ...kVA Maximum configuration 0 732 kVA Models with 48Vdc 900 W power supplies 48 60 nominal V dc 25 8 A Input kilovolt amperes kVA approximately Minimum configuration 0 14 kVA Maximum configuration 1 237 kVA BTU output Minimum configuration 461 Btu hr 135 watts Maximum configuration 6667 Btu hr 1954 watts Acoustics 6 6 bels operating 6 4 bels idle Vibration Operating 0 21 G rms at 5 Hz to 500 Hz for ...

Page 50: ...ervice request registration in Lenovo s call management system and the restoration of the product to conformance with its specification by a Service Technician The following Lenovo warranty service upgrades are available Warranty and maintenance service upgrades Three four or five years of 9x5 or 24x7 service coverage Parts delivered or technician installed parts from next business day to 4 or 2 h...

Page 51: ...er priorities Your new systems will be configured and ready for your software installation Regulatory compliance The server conforms to the following regulations FCC Verified to comply with Part 15 of the FCC Rules Class A Canada ICES 003 issue 5 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class A Australia New Zealand AS NZS CISPR 22 Class A AS NZS 60950 1 ...

Page 52: ...Dual 3 port ESMs 12x 4TB 3 5 HDDs 4x 0 5m SAS cables 4587EJU D1212 LFF Chassis Dual 3 port ESMs 12x 6TB 3 5 HDDs 4x 0 5m SAS cables 4587EKU D1212 LFF Chassis Dual 3 port ESMs 12x 8TB 3 5 HDDs 4x 0 5m SAS cables 4587ELU D1212 LFF TopSeller models North America NA and Europe Middle East and Africa EMEA Lenovo Storage D1212 LFF Dual ESM Disk Expansion Enclosure US English documentation 4587E11 D1224 ...

Page 53: ...xternal storage systems Description Part number Lenovo ThinkSystem DS Series Storage SAS connectivity Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit US English documentation 4599A41 Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit Simplified Chinese documentation 4599A4C Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit Japanese documentation 4599A4J Lenovo ThinkSystem DS2200 SF...

Page 54: ...Lenovo Storage V Series SAS except V7000 V7000F iSCSI or FC connectivity Lenovo Storage V3700 V2 LFF Control Enclosure 6535C1D Lenovo Storage V3700 V2 LFF Control Enclosure TopSeller 6535EC1 Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2D Lenovo Storage V3700 V2 SFF Control Enclosure TopSeller 6535EC2 Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3D Lenovo Storage V3700 V2 XP LFF Con...

Page 55: ...2TB 4yr SW S S 5135Q3x Lenovo Storage DX8200D ServerSAN High 32TB 5yr SW S S 51356Wx Lenovo Storage DX8200N with 1x N2226 HBA Requires a supported external drive enclosure 5128C1x Lenovo Storage DX8200N with 2x N2226 HBAs Requires a supported external drive enclosure 5128C2x Lenovo Storage DX8200C Series S3 cloud storage Lenovo Storage DX8200C 56TB 14x 4TB HDDs with Cloudian HyperStore 3yr HW SW S...

Page 56: ...S 6171S7R External tape backup libraries IBM TS3100 Tape Library Model L2U 61732UL IBM TS3200 Tape Library Model L4U 61734UL Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 6173 LTO Ultrium 5 Fibre Channel Drive 00NA107 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA113 6173 LTO Ultrium 6 Fibre Channel Drive 00NA115 6173 LTO Ultrium 6 Half High Fibre Drive Sled 00NA119 6173 LTO...

Page 57: ...h Rear to Front 7159B1X Lenovo ThinkSystem NE1072T RackSwitch Rear to Front 7159C1X Lenovo RackSwitch G8124E Rear to Front 7159BR6 Lenovo RackSwitch G8264 Rear to Front 7159G64 Lenovo RackSwitch G8264CS Rear to Front 7159DRX Lenovo RackSwitch G8272 Rear to Front 7159CRW Lenovo RackSwitch G8296 Rear to Front 7159GR6 25 Gb Ethernet switches Lenovo ThinkSystem NE2572 RackSwitch Rear to Front 7159E1X ...

Page 58: ...DB400D 32Gb FC Director up to 192 ports 8U Enterprise SW 6684B2A Lenovo ThinkSystem DB800D 32Gb FC Director up to 384 ports 14U Enterprise SW 6682B1A For more information see the list of Product Guides in the Rack SAN Switches category http lenovopress com storage switches rack rt product guide Rack cabinets The following table lists the rack cabinets that are offered by Lenovo that can be used in...

Page 59: ...ard w Int Pointing Device USB Italian 141 RoHS v2 46W6725 Keyboard w Int Pointing Device USB Japanese 194 RoHS v2 46W6726 Keyboard w Int Pointing Device USB Korean 413 RoHS v2 46W6727 Keyboard w Int Pointing Device USB LA Span 171 RoHS v2 46W6728 Keyboard w Int Pointing Device USB Norwegian 155 RoHS v2 46W6729 Keyboard w Int Pointing Device USB Polish 214 RoHS v2 46W6730 Keyboard w Int Pointing De...

Page 60: ...19 Switched Monitored 32A 200 240V 346 415V 3Ph PDU w IEC60309 532P6 cord 00YJ782 0U 12 C13 12 C19 Switched and Monitored 48A 200 240V 3Ph PDU w IEC60309 460P9 line cord 00YJ783 1U 9 C19 3 C13 Switched and Monitored DPI PDU without line cord 46M4002 1U 9 C19 3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P Gnd cord 46M4003 1U 12 C13 Switched and Monitored DPI PDU without line cord 46M4004 ...

Page 61: ...ble power supply units The following table lists the uninterruptible power supply UPS units that are offered by Lenovo that can be used in System x3550 M5 solutions Table 53 Uninterruptible power supply units Description Part number RT1 5kVA 2U Rack or Tower UPS 100 125VAC 55941AX RT1 5kVA 2U Rack or Tower UPS 200 240VAC 55941KX RT2 2kVA 2U Rack or Tower UPS 100 125VAC 55942AX RT2 2kVA 2U Rack or ...

Page 62: ...g into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and payment re...

Page 63: ...re not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties Al...

Page 64: ...rProven System x ThinkServer ThinkSystem ToolsCenter TopSeller TruDDR4 UltraNav UpdateXpress System Packs The following terms are trademarks of other companies Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft PowerShel...

Reviews: