background image

LTO-QUEST & LTO-QUEST HD

USER GUIDE

14400 NW Greenbrier Pkwy | Beaverton, OR 97006 USA  |  1-800-538-7653  |  leupold.com

Summary of Contents for LTO-QUEST

Page 1: ...LTO QUEST LTO QUEST HD USER GUIDE 14400 NW Greenbrier Pkwy Beaverton OR 97006 USA 1 800 538 7653 leupold com...

Page 2: ...LTERS SCREEN 11 IMAGE CAPTURE SCREEN 12 MENU SCREEN 13 GALLERY 14 DEVICE SETTINGS 16 TEMPERATURE UNITS 19 POWER SETTINGS 20 DISPLAY SETTINGS 21 FLASHLIGHT SETTINGS 22 ABOUT SCREEN 23 POWER OFF THERMAL...

Page 3: ...or product damage caused by battery exposure to extreme heat store the device out of direct sunlight and away from other extreme heat sources Dispose of battery and device in a proper manner Mac is a...

Page 4: ...r and dust resistant 6 Individual images can be easily renamed for quick identification once they have been transferred to your PC All temperature readings stay affixed to the image on storage 7 Organ...

Page 5: ...pen and the USB port for charging highlighted For best results Leupold recommends charging your LTO Quest using the included micro USB cable by connecting it to your computer or a USB enabled wall out...

Page 6: ...ery Supplied 5 pin cable between charger and LTO Quest USB Port Note Not all OTG cables are built with the same specifications through all suppliers The cable provided in the box is built to our speci...

Page 7: ...TO Quest The Splash screen A long press of the CENTER button will cause the device to activate and start up the software The splash screen will then display Note that the version is also displayed The...

Page 8: ...the CENTER button and hold until the screen lights The button function ribbon at the top of the screen defines the meaning of the three buttons For each of the setup screens use the LEFT and RIGHT but...

Page 9: ...your LTO Quest The startup sequence Splash screen Select time format Setup complete screen Enter date and time Select your language Select date format Press the CENTER button to power on the device EN...

Page 10: ...10 QUICK START GUIDE Thermal Imaging Imaging screen options FILTERS MENU CAPTURE LEFT button RIGHT button CENTER button RETURN TO DEVICE...

Page 11: ...is cycled through the available filters technically known as look up tables or LUTs The name of the filter currently applied is displayed at the bottom of the image When you have reached your desired...

Page 12: ...red image are displayed at the bottom center of the screen while the temperature and units for the area within the reticle or target are displayed just below the reticle Every time the CAPTURE button...

Page 13: ...13 QUICK START GUIDE Menu Screen The Menu screen See the following sections for descriptions of the categories of settings found on the Menu screen...

Page 14: ...e and units for the area within the reticle or target is displayed Note that the current image number and the total number of images are also displayed at the bottom right If the Gallery is empty the...

Page 15: ...15 QUICK START GUIDE Gallery The Gallery Options screen The Empty Gallery screen...

Page 16: ...The Device Settings screen allows you to access general camera settings date and time language power as well as performing a factory restore The General Settings screen allows you to specify the unit...

Page 17: ...Time Format screen Choosing one of the two date formats causes LTO Quest to immediately set all date displays and captures to the desired format Choosing one of the two time formats causes LTO Quest t...

Page 18: ...reen Language screen Setting values for the date and time will cause LTO Quest to update all displays and captures of date and time Choosing a language causes LTO Quest to immediately set all dialogs...

Page 19: ...19 QUICK START GUIDE Temperature Units The Units screen The user can choose to display and capture temperatures in one of two available units Fahrenheit or Celsius...

Page 20: ...The Power Settings screen allows you to choose settings for the auto power management and the LCD display screen brightness Enabling the Auto Turn Off setting will automatically turn off the thermal...

Page 21: ...splay brightness setting This setting allows you to control the amount of light generated by the LCD display Managing this setting allows you to conserve battery power or limit the amount of light fro...

Page 22: ...22 QUICK START GUIDE Flashlight Settings Low intensity setting You can also adjust the flashlight s low intensity setting applied with the second button click...

Page 23: ...23 QUICK START GUIDE About The About screen This option displays your LTO Quest s model number serial number and software version...

Page 24: ...24 QUICK START GUIDE Power Off Thermal The Power Off Thermal option is an alternative to the long hold of the CENTER button Power off thermal CENTER button...

Page 25: ...than 10 remaining 35 to 65 remaining 65 to 85 remaining More than 85 remaining Battery Charge Select this option to turn off the thermal imager The device is connected to battery charger or USB port...

Page 26: ...FILTERS via the LEFT button press the LEFT or RIGHT button until the desired image filter is displayed then select it via the CENTER button Filters are subjective to the user and preferred based on ob...

Page 27: ...ng the SIDE button once powers the LED flashlight to its high intensity setting A second press of the SIDE button powers the flashlight to its low intensity setting and the third press causes the flas...

Page 28: ...High intensity setting The Flashlight screen allows you to adjust the intensity level of the two click levels of the LED flashlight You can adjust the flashlight s high intensity setting applied with...

Page 29: ...on allows the user to restore all of the settings to the default settings and options that reflect the state of the device when it left the factory After power cycling the user will then be required t...

Page 30: ...em to your computer etc Your microSD card can also be erased and reused whether on your PC via an adapter in your LTO Quest or via a USB connection The Leupold LTO Quest is designed to hold a maximum...

Page 31: ...the microSD card should become visible as a storage device or removable drive Once visible open the DCIM folder to access the photos You can copy or drag photos to your computer Mac or PC or Tablet Mo...

Page 32: ...sing should be replaced immediately and not used Repairing Do not open the device and do not attempt to repair it yourself Disassembling the device may damage it or may cause injury to you Disassembli...

Page 33: ...ber cloth with water and gently wipe the screen then go over it again with a dry section of the cloth to wipe away any moisture Avoid getting moisture in any of the openings Cables should be kept free...

Page 34: ...ty b Check if the microSD card is full If card is full delete images or insert a new microsSD card c Try accessing the microSD card on your PC or Mac through an adapter 3 The thermal image appears blu...

Page 35: ...he microSD Card will not stay inserted a Be sure that the microSD Card or the slot is not damaged b Be sure there are no foreign objects i e lint sand etc in the slot preventing the microSD Card from...

Page 36: ...Temperature Measurement Type Sensitivity F 1 Detection Range Accuracy 25 C 14 to 149 F 10 to 65 C 40 to 131 F 40 to 55 C 32 to 113 F 0 to 45 C Water and dust resistant Drop test per 1 meter onto pave...

Page 37: ...nology Focal Length F Focus Range Detection Distance Type Lumens Default Hi Default Low Spot Field of View Flood Field of View Chalcogenide Glass w Anti reflective Coating 4 mm F 1 2 6 inches to infin...

Page 38: ...y Capacity Voltage Charge Current On included power adapter In live USB port Battery Life Thermal Camera Only Light 100 In storage from 100 charge 2 4 TFT Color LCD LTO Quest HD 320x240 QVGA LTO Quest...

Page 39: ...USB Connection USB Port Mass Storage Class Accessories Belt Clip Tripod Mount Warranty Device Removable microSD up to 32GB FAT32 Portable Network Graphics PNG format Yes 2200 142000 Micro B Windows MA...

Page 40: ...n low voltage distribution systems Industrial scientific and medical ISM radio frequency Equipment Electromagnetic disturbance characteristics Limits and methods of measurement Electromagnetic compati...

Page 41: ...ompatibility EMC Part 4 5 Testing and measurement techniques Surge immunity test Electromagnetic compatibility EMC Part 4 6 Testing and measurement techniques Immunity to conducted disturbances induce...

Reviews: