background image

 

 

HFM 3500D 
combined mobile RFID- and 
Barcode- hand held reader with 
cable connection 

Short Description 

Version V 2.0 

Summary of Contents for HFM 3500D

Page 1: ...HFM 3500D combined mobile RFID and Barcode hand held reader with cable connection Short Description Version V 2 0 ...

Page 2: ...NTS 3 SAFETY NOTICES 4 GENERAL SAFETY NOTICES 4 APPROVED PURPOSE 4 WORKING SAFELY 5 INSTALLATION 6 CONNECTING THE DEVICE 6 HOW IS THE BEST WAY TO SCAN OR READ 7 TECHNICAL DATA 8 READ CHARACTERISTICS 9 USING THE HFM 3500D 10 FUNCTIONS 10 DEVICE RESET FACTORY DEFAULT 12 PARAMETER SETTING 12 TELEGRAM COMMAND STRUCTURE 13 MENU STRUCTURE 14 HFM 3500D AT THE SERIAL PC INTERFACE 17 HFM 3500D WITH MA 204I...

Page 3: ... 3 CONNECTION TO LEUZE MULTINET PLUS 22 CONNECTION TO PROFIBUS 22 CONNECTION TO PROFINET RT I O 22 CONNECTION TO ETHERNET TCP IP 22 Delivery contents HFM 3500D 1 Mobile combi RFID Barcode Hand held reader 2 RS232 spiral cable length 4m 3 Bypack paper ...

Page 4: ... Approved purpose Attention The protection of personnel and the device cannot be guaranteed if the device is operated in a manner not complying with its intended use Combined mobile Barcode and RFID readers of the HFM 35x0D series are conceived as mobile devices With integrated decoder for manual object identification with typical barcodes and HF transponders In particular unauthorized uses includ...

Page 5: ...ntion Laser radiation If you look into the beam path over a longer time period the retina of your eye may be damaged Never look directly into the beam path Do not point the beam at persons The combi devices HFM 35x0D comply to the safety standards EN60825 for a class 2 product The HFM35x0D uses a low power visible laser diode The average laser power is less than 1mW in accordance with the definiti...

Page 6: ...ou are using a RS232 USB cable converter the converter cable is just plugged into the 9 pol Sub D of the standard RS232 cable 2 The Standard RS232 cable allows either to use a separate Power supply NT Hx5x0 50110676 or using via PIN9 of the cable a power supply inside the PLC The pinning is printed further on 3 Plug in the power supply into a power socket 100 230VAC not necessary when PIN9 is used...

Page 7: ... The red LED Line is smaller and narrow if the device is close to the code Codes with small and thin bars should be read with a smaller distance for larger codes the distance should be bid enough to have the Complete code within the red line For reading the RFID tag the environment should have less possible metal and the device should be held very close above the tag The antenna of the device shou...

Page 8: ...ion USB COM Port with converter cable Code and Transponder types readable Barcodes Code 39 Code 128 Code 93 EAN 8 13 2 5 Int after release readable Transponder Phillips I Code SLI Texas TAG IT HFI Mechanical Data Display OLED 128x64 Key board 19 keys Weight 172 g without cable Dimensions 135 x 104 x 145 mm Material ABS silver grey Conncetion spiral cable 4m Environmental Data Valid Standards EN 30...

Page 9: ...er selectinog factory set Code 39 Code 128 EAN 13 UPC A EAN 8 UPC E Interleaved 2 5 Codabar Code 93 Chinese 2 5 Codablock F ITF 6 ITF 14 No of digits range 1 255 Modul recommended 0 2 to 1 0mm Working area RFID Antenna 0 5 10 25mm distance Readable Transponder Types I Code SLI TAG It HFI out of ISO15693 TFM08 TFM05 TFM03 HFM ...

Page 10: ...on Press Button und displays the Info Depending on the setting an output via interface of the information is possible too The data is always stored in hexadecimal format on the transponder A data output is possible in ASCII format too but Data Serial no only Error messages are shown in the display and Parameter possibly transmitted via interface Up to 32 Characters data 8Blocks can be read in one ...

Page 11: ...nd FCx directly without action from user e g to proceed application dependend process steps Command FC1 x selects function SCAN Barcode FC2 x function SCAN Barcode EDIT RFID FC3 x the function SCAN RFID FC4 x function EDIT RFID and FC5 x the function SCAN All The selection is shown on the display and is activated when used FC with the Trigger button The change of any function is shown via display ...

Page 12: ...ATA only OFF pre set ON ON means complete telegram RFID Interface Baud rate and Databits can be set between 4800Bd and 115kBd pre set 9600Bd 8N1 Keyboard Password via Com Password ON OFF MoreMessages activation of different messages select with Green as character in Display The complete menu structure is in the chapter menu Device reset Factory default With selecting the menu point Reset device in...

Page 13: ...on by user needed device ready after key pressed e g scan Barcode FC1 FC 1 5 x functions select via interface and response FC3x OK without activiation from user device ready after beep e g scan RFID FC3x BP 1 2 activates buzzer for 1s with high low beep as signal MDTEXT Textinfo an the device display for feed back to user 16characters W05001xxxxxxxx Data string for writing onto Transponder Blockwi...

Page 14: ...input via key board Fixed Postamble after input via key board Select sequence Postamble Terminator Select Serial number Data for Data input Startblockno and No of Blocks Type in Start block no and No of Blocks Type in Telegram Start character Type in Telegram End character Select ASCII HEX Select ALL compl Telegram RFID Data only OFF no Data output via interface Select System Barcode Run Program R...

Page 15: ...e interface no change Key board block ON OFF Activation of Messages etc select with green key ON OFF for Send via Interface ON OFF for Send NORead Message ON OFF Input line Quantiy Set separator between code and quantity Interface Parity Databit Stopbit Def COMport Key board Password via Password Activation Baudrate More Send NO Read Use Qty Qty separator ...

Page 16: ...n Device Date time via Key board Set contrast and orientation of display Set Bieper volume key click shows Voltage select auto power off shows Version of Hardware Firmware select sets device to factry defaults Date Time Display Sound Power Reset Device Version ...

Page 17: ...ta 5 to 5V 3 RX Receive Data 5 to 5V 5 GND Signal Ground 9 Signal 4 5 6 VDC external Via Connector or direct with Power supply via separate power plug NT Hx5x0 Art Nr 501 10676 necessary parts 1x 50110552 HFM 3500D incl RS232 cable 1x 50110676 NT Hx5x0 Power supply 100 240VAC 6VDC Pinning of the 9 Pol D Sub female PIN No Signal Description 2 TX Transmit Data 5 to 5V 3 RX Receive Data 5 to 5V 5 GND...

Page 18: ...net 50112892 MA 208i or Profibus 50112893 MA 204i Please connect the HFM to the 9 PIN Sub D HFM 3500D with MA 21 multinet Separate power supply needed Note The RS 232 of the MA21 is set to 9600 Baud 7 Databits 1 Stoppbit Parity Even Postfixes CR LF Please change at HFM for proper functionality Necessary parts 1x 50110552 HFM 3500D incl RS232 cable 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 Pinning...

Page 19: ...ly needed Necessary parts 1x 50110552 HFM 3500D incl RS232 cable 1x 50110676 NT Hx5x0 Power supply 100 240VAC 6VDC 1x 50110677 KB USB RS232 converter cable 1m USB converter cable KB RS232 USB Length 1m Art No 50110677 Pinning of the USB connector 9 pin Sub d like above Note Operation with external power supply recommended USB Type A Plug Signal Description 1 VCC IN 5 VDC 2 Data Data 3 Data Data 4 ...

Page 20: ...rinted usually in the manual of the PLC PC 4 If you checked all steps before and the device is still not ready change the power supply to another one 5 Please check the used interface at the device and your PC PLC are compatible Information about that are printed in the PC s PLC s manual 6 Barcode Please check the quality of the Barcode Labels and the correct symbologies are released Damaged label...

Page 21: ...scription Interface Picture 50110552 HFM 3500D incl cable TTL RS232 Accessories Accessories for HFM 35xx Series Art No Discription Picture 50103403 NT Hx5x0 external Power supply for HFM HFU Base Hx520 for RS 232 cable 100 240VAC 6 Volt DC 50110677 USB converter cable for HFM HFU or Base Hx520 ...

Page 22: ...on to ProfiNet RT I O MA 248i ProfiNet Gateway with 5 VDC power supply for hand helds Art Nr 50112891 KB JST HS 300 connection cable MA 2xxi and 9 pin Sub D 5Volt via PIN9 300mm long Art Nr 50113397 Connection to Ethernet TCP IP MA 208i Ethernet Gateway with 5 VDC power supply for hand helds Art Nr 50112892 KB JST HS 300 connection cable MA 2xxi and 9 pin Sub D 5Volt via PIN9 300mm long Art Nr 501...

Reviews: