PK-A3241-10-02-5A

2-POLE 3-WIRE

POWER INTERRUPTING RECEPTACLE

Cat. Nos. 23030-L, 23000-LHG

Rated: 20A-125VAC

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com

LIMITED 10 YEAR WARRANTY AND EXCLUSIONS

/HYLWRQZDUUDQWVWRWKHRULJLQDOFRQVXPHUSXUFKDVHUDQGQRWIRUWKHEHQH¿WRIDQ\RQHHOVHWKDWWKLVSURGXFWDWWKHWLPHRILWVVDOHE\/HYLWRQLVIUHHRIGHIHFWVLQPDWHULDOVDQGZRUNPDQVKLSXQGHUQRUPDODQGSURSHU

XVHIRUWHQ\HDUVIURPWKHSXUFKDVHGDWH/HYLWRQ¶VRQO\REOLJDWLRQLVWRFRUUHFWVXFKGHIHFWVE\UHSDLURUUHSODFHPHQWDWLWVRSWLRQ

For details visit www.leviton.com or call 1-800-824-3005.

7KLVZDUUDQW\

H[FOXGHVDQGWKHUHLVGLVFODLPHGOLDELOLW\IRUODERUIRUUHPRYDORIWKLVSURGXFWRUUHLQVWDOODWLRQ7KLVZDUUDQW\LVYRLGLIWKLVSURGXFWLVLQVWDOOHGLPSURSHUO\RULQDQLPSURSHUHQYLURQPHQWRYHUORDGHGPLVXVHG

RSHQHGDEXVHGRUDOWHUHGLQDQ\PDQQHURULVQRWXVHGXQGHUQRUPDORSHUDWLQJFRQGLWLRQVRUQRWLQDFFRUGDQFHZLWKDQ\ODEHOVRULQVWUXFWLRQV

There are no other or implied warranties of any kind, including 

PHUFKDQWDELOLW\DQG¿WQHVVIRUDSDUWLFXODUSXUSRVH

EXWLIDQ\LPSOLHGZDUUDQW\LVUHTXLUHGE\WKHDSSOLFDEOHMXULVGLFWLRQWKHGXUDWLRQRIDQ\VXFKLPSOLHGZDUUDQW\LQFOXGLQJPHUFKDQWDELOLW\DQG¿WQHVVIRU

DSDUWLFXODUSXUSRVHLVOLPLWHGWRWHQ\HDUV

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, 

ORVWVDOHVRUSUR¿WVRUGHOD\RUIDLOXUHWRSHUIRUPWKLVZDUUDQW\REOLJDWLRQ

7KHUHPHGLHVSURYLGHGKHUHLQDUHWKHH[FOXVLYHUHPHGLHVXQGHUWKLVZDUUDQW\ZKHWKHUEDVHGRQFRQWUDFWWRUWRURWKHUZLVH

FOR CANADA ONLY

)RUZDUUDQW\LQIRUPDWLRQDQGRUSURGXFWUHWXUQVUHVLGHQWVRI&DQDGDVKRXOGFRQWDFW/HYLWRQLQZULWLQJDW

Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 

165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9

RUE\WHOHSKRQHDW

1 800 405-5320.

ENGLISH

INSTALLATION

WARNINGS:

•   

TO AVOID FIRE, SHOCK OR DEATH, TURN OFF POWER 

DWFLUFXLWEUHDNHURUIXVHDQGWH

st

WKDWWKHSRZHULVRႇEHIRUHZLULQJ

!

• 

TO AVOID FIRE, SERIOUS INJURY OR DEATH, DO NOT COAT CONDUCTORS WITH TIN.

CAUTIONS:

  To be inst

DOOHGDQGRUXVHGLQDFFRUGDQFHZLWKHOHFWULFDOFRGHVDQGUHJXODWLRQV

‡ ,I\RXDUHXQVXUHDERXWDQ\SDUWRIWKHVHLQ

structions, consult an electrician.

•  Use the device with 

copper wire only

.

‡ 7HUPLQDOFDSDFLW\WR$:*VROLGRU

stranded building wire.

1. Wire receptacle

 )RUEDFNZLULQJVWULSFRQGXFWRUVFPLQ

  Terminate conductors as follows:

•  

20A

-125VAC:

)XOO\LQVHUWJURXQGLQJ

 

FRQGXFWRUJUHHQJUHHQ\HOORZRUEDUHZLUH

 

to terminal 

GR 

JUHHQVFUHZ

 ‡ )XOO\LQVHUWKRWFRQGXFWRUEODFNWRWHUPLQDO

Y

DQGQHXWUDOFRQGXFWRUZKLWHWRWHUPLQDO

Z.

NOTE:

7LJKWHQDOOWHUPLQDOVFUHZVWRLQOEV1P

2. Mount receptacle in electrical box with screws provided

PRISE SECTIONNEUSE BIPOLAIRE À TROIS FILS

N

os

 de cat. 23030-L, 23000-LHG

Valeurs nominales : 20 A, 125 V c.a.

INSTALLATION

FRANÇAIS

Z

Y

GR

Z

Y

GR

AVERTISSEMENTS

•  POUR ÉVITER LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU D’ÉLECTROCUTION, COUPER LE COURANT 

DXIXVLEOHRXDXGLVMRQFWHXUHWV¶DVVXUHU

TXHOHFLUFXLWHVWELHQFRXSpDYDQWGHSURFpGHUjO¶LQVWDOODWLRQ

•  POUR ÉVITER LES RISQUES D’INCENDIE OU ENCORE DE LÉSIONS CORPORELLES GRAVES OU MORTELLES, IL NE FAUT PAS ÉTAMER LES 

CONDUCTEURS

.

MISES EN GARDE

• 

/HVSURGXLWVYLVpVDX[SUpVHQWHVGRLYHQWrWUHLQVWDOOpVHWXWLOLVpVFRQIRUPpPHQWDX[FRGHVGHO¶pOHFWULFLWpHQYLJXHXU

• 

¬GpIDXWGHELHQFRPSUHQGUHOHVSUpVHQWHVGLUHFWLYHVHQWRXWRXHQSDUWLHRQGRLWIDLUHDSSHOjXQpOHFWULFLHQ

• 

1¶XWLOLVHUFHVGLVSRVLWLIVTX¶DYHFGX¿OGHFXLYUH

• 

)LOVDFFHSWpV

 

¿OVGHEkWLPHQWSOHLQVRXWRURQQpVGHFDOLEUHj$:*

1. Raccorder la prise.

3RXUOHFkEODJHDUULqUHVHXOHPHQWGpQXGHUOHVFRQGXFWHXUVVXUFPSR

(ႇHFWXHUOHVWHUPLQDLVRQVFRPPHVXLW

•  

20A

, 125 V c.a. :

 

LQVpUHUFRPSOqWHPHQWOHFRQGXFWHXUGHWHUUHYHUWYHUWMDXQHRXGpQXGpGDQVOD

borne 

GR

YLVYHUWH

• 

,QVpUHUFRPSOqWHPHQWOHFRQGXFWHXUDFWLIQRLUGDQVODERUQH

HWOHFRQGXFWHXUQHXWUHEODQFGDQVOD

borne 

Z

.

REMARQUE

 : 

VHUUHUOHVYLVGHVERUQHVHQDSSOLTXDQWXQFRXSOHGHj1PjSROE

2. Fixer la prise dans la boîte murale au moyen des vis fournies.

Z

Y

GR

Z

Y

GR

WEB 

VERSION

Reviews: