120 VAC Junction Box Kit
Cat. No. 47605-ACN
DI-016-47605-20F
DESCRIPTION
This AC Junction Box Kit, an accessory for Leviton’s Structured Media™ Center (SMC) features one 15
Amp receptacle housed in a white metal enclosure which drops into an opening in the bottom of the SMC.
The unit has several cable entry knockouts for power service connections.
1.
When positioning the SMC on the wall, ensure that adequate space is provided for the
Junction Box Kit and any associated AC wiring.
2.
Remove the rectangular knockout (A) in the bottom of the SMC
(figure 1).
3.
Remove a cable entry knockout (B) in the Junction Box Kit for electrical service to the unit.
User-supplied conduit fittings or cable clamps (C) are recommended to ready the cable entry holes for
electrical wiring
(figure 1).
4.
Install electrical wiring. An independent 15 Amp circuit should be used to provide power to the
Junction Box Kit.
Wire the receptacles as shown in
figure 2.
Wiring Schemes:
To Quickwire™ (Preferred wiring method): Remove insulation from wires according to "strip gauge" on
back of device (about 5/8"). Insert straight #14 AWG solid copper wires into round Quickwire holes. If
the receptacle must be replaced or rewired after Quickwiring, press the tip of a small screwdriver in the
release slot and back the wire out gradually. If the receptacle or Quickwire terminal becomes damaged,
DO NOT reuse. Quickwire terminals are for use on 15 Amp branch circuits only.
NOTE:
Use only #14 AWG solid copper conductors! Do not use Quickwire terminals on 20 Amp branch
circuits; use side wiring instead.
To Side Wire:
Remove insulation from wires according to "strip gauge" on back of device about 5/8".
Loop wires clock-wise 3/4 turn around terminal screws: HOT (Black) wire to BRASS screw, NEUTRAL
(White) wire to SILVER screw, GREEN or BARE (Ground) wire to GREEN screw. Tighten all screws
firmly. Terminal screws accept up to #10 AWG copper or copperclad wire.
5.
Drop the Junction Box Kit housing into the SMC opening. Attach the Junction Box to the SMC with the
four, #6 x 3/8-inch thread-forming screws provided. Tighten all screws securely
(figure 1).
6.
Place the wired receptacle into the housing. Verify that all wiring connections are inside the housing,
without pinched or otherwise damaged wires.
7.
Attach the receptacle to the Junction Box Kit with the two, #6-32 x 1/2 inch screws provided
(figure 1).
8.
Install the Decora-style wallplate using the two provided screws, attaching it to the mounted receptacle
(figure 1).
9.
Safety plugs are included with the unit to keep wire clippings and other foreign matter out of the outlets
during installation and when outlets are not in use.
INSTALLATION
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper
use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option.
For details visit www.leviton.com or call 1-800-824-3005.
This warranty
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose
, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a
particular purpose, is limited to two years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or profits or delay or failure to perform this warranty obligation
. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at
Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9
or by telephone at
1 800 405-5320.
WARNINGS AND CAUTIONS
•
WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
•
WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY:
- DO NOT
push objects of any kind into this product through openings, as they may touch dangerous voltages.
- DO NOT
touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.
• This device is intended for single branch circuit installations only.
• Use this device with
copper or copper-clad wire only.
• Use Quickwire™, if possible, to wire receptacle. Due to close tolerances, side wiring is the least preferred wiring method.
• Read and understand all instructions. Follow all warnings and instructions marked on the product.
•
Do not use this product near water - e.g.,
near a tub, wash basin, kitchen sink or laundry tub, in a wet basement, or near a swimming pool.
• Never install communications wiring or components during a lightning storm.
• Never install communications components in wet locations unless the components are designed specifically for use in wet locations.
• Use caution when installing or modifying communications wiring or components.
• SAVE
THESE
INSTRUCTIONS.
ENGLISH
INSTALLATION INSTRUCTIONS
White
/Bl
a
nc/
Blanco
Green
/Vert/
Verde
Black
/Noir/
Negro
B
C
A
1
2
WEB
VERSION