background image

•  For indoor applications only. DO NOT use outdoors.

•  DO NOT use this equipment for other than intended use.

•  DO NOT mount near gas or electric heaters.

•  Equipment should be mounted in locations and at heights where it will not 

be subjected to tampering by unauthorized personnel.

•  Use this device with COPPER OR COPPER CLAD WIRE ONLY.
• 

SAVE THESE INSTRUCTIONS.

Wireless Intelligent Fixture Controller

INSTALLATION INSTRUCTIONS

ENGLISH

PK-A3378-10-00-2A-X3

The Intellect™ Wireless Intelligent Fixture Controller integrates wireless 

control technology directly into lighting fixtures. The controller is designed 

to be installed into the wiring compartment of the fixture and interface 

to the driver via 0-10V or DALI, depending on the model. The fixture 

controller interfaces with Leviton’s wireless systems using its built-in radio. 

The controller is designed to be powered from the driver and in the case 

of 0-10V, requires a dim-to-off driver to be used. The controller may be 

installed into your fixture by the fixture manufacturer or may be added in 

the field if all requirements are met. When the controller is pre-installed on 

a fixture, refer to fixture documentation for installation methods, means, 

and requirements.

WARNINGTO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER 

at circuit breaker or fuse and test that power is off before wiring!

Installation

1.

    

Secure the controller within the wiring compartment using the included  
mounting screws. 

2.

    

Remove 4 to 5 mm of insulation from each circuit conductor.

3.

    

Make sure ends of conductor are straight.

4.

    

Push conductor firmly into appropriate wire connector.

5.

    For 

controllers with external antenna (ZL070-B0A, B2A,  

ZL0D0-B0A): The grommet on the end of the antenna wire is 

designed for installation into a 2 mm diameter hole to provide stability 

for the antenna wire outside the fixture. Locate a 2 mm hole as 

needed on the fixture housing. Thread antenna wire through hole. 
Push grommet into hole until secure. 

6.

    

If installing with Emergency Sense Module (ZL027-0ES): Connect 

the Emergency Sense Module to the Controller using the cable 

included with the ZL027-0ES.

7.

    

Connect the Emergency Sense Module to Normal Power.

8.

    

Restore power at circuit breaker or fuse.

9.

  

  Proceed to device enrollment per the included sheet and configuration 

per your system requirements. Installation is complete.

Installation Requirements 

  

Installation and servicing should always be performed by qualified 

personnel.

  

Mounts within fixture wiring compartment.

  

Dim-to-OFF LED driver with 12-24V AUX power supply and 0-10V or 

DALI control.

Wiring Diagrams

ZL070-B20, B2A

Emergency Wiring

When used for emergency lighting, the ZL027-0ES Emergency Sense 

Module is required and shall be connected using the supplied cable. 

The control input wires for the emergency light fixture are connected 

to emergency power, and the Emergency Sense Module is connected 

to normal power. Upon loss of normal power, the relay closes, and the 

controller or sensor 0-10V lines go to high impedance allowing the load to 

go to full output powered from the EM Source. Commands to change the 

device output from full are ignored when the Emergency Sense Module is 

in this mode. Upon restoration of normal power, the controller or sensor 

will automatically resume normal operation.

Emergency Self-Test: NFPA 101 Life Safety Code and NEC (Article 

700.3(B)) requires regular testing of all emergency equipment. To 

perform a test of these products, a Test Switch that is a normally open, 

momentary-break type, that returns the equipment to normal status when 

released can be installed locally to interrupt normal power and perform 

emergency system test. 
*The diagram below depicts a “Momentary-Break Type Test Switch” ($) 

on the normal power line to trigger the emergency systems test. Clarify 

requirements with all local authorities.

Intellect™

EMERGENCY

SENSOR
MODULE

ZL027-0ES

FIXTURE

LIGHT FIXTURE

EMERGENCY

POWER

LIGHTING CIRCUIT

LINE FEED

(NORMAL POWER)

AUX +

AUX -

VIOLET (DIM +)

GRAY (DIM -)

LINE

LINE

NEUTRAL

NEUTRAL

Controller or
Sensor

12 in. Cable
provided
with
Emergency
Sensor Module

$*

NL

LN

Neutral

Line

2-Channel

LED Driver

With Auxiliary

Power Output

GND

Earth

(-) LED-2

TO CH-2

LED Modules

TO CH-1

LED Modules

(+) LED-2

(-) LED-1

(+) LED-1

(+) AUX

(-) AUX

(+) DIM-1

AUX+

AUX-

DIM1+

DIM2+

DIM-

(-) DIM-1

(-) CCT-2

(+) CCT-2

NL

LN

Neutral

Line

1-Channel

LED Driver

With Auxiliary

Power Output

GND

Earth

(-) LED

(+) LED

(+) AUX

AUX+

AUX-

DIM1+

DIM-

(-) AUX

(+) DIM

(-) DIM

WC, 0-10V, DALI 

Cat. Nos. ZL070-B00, B0A; ZL070-B20, B2A; ZL0D0-B00, B0A

NL

LN

Neutral

Line

DALI

LED Driver

GND

Earth

(-) LED

(+) LED

(+) DALI

(-) DALI

DALI+

DALI-

ZL0D0-B00, B0A 

Reset 

Switch

LED Indicator

ZL070

Reset 

Switch

LED Indicator

ZL0D0

ZL070-B00, B0A

WARNINGS

• 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

•  TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR 

FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  Controller is intended to be installed by the fixture manufacturer, but in some cases may be 

installed in the field. Field installation must use approved electrical enclosures.  

NOTE: Suitable for use in air handling spaces (plenums).

•  The use of accessory equipment not recommended by the manufacturer may cause an 

unsafe condition.

Product Description

NOTE: Antenna applies to B0A and B2A models only.

Reviews: