WARNING
ADVERTENCIAS
PK-A3201-10-02-0B
FCC STATEMENT
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
IC STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may
cause undesired operation of the device.
This product is covered by U.S. Patents Nos. 6,040,967; 6,282,070;
6,381,112; 6,437,953; 6,646,838; 6,657,834; 6,944,001; 7,336,458;
8,054,595; 8,130,480; 6,288,882; 6,717,782; 6,788,173; 8,599,522;
6,088,205; 6,433,978; 6,639,769; 8,599,523, 9,577,420 and
corresponding foreign patents.
Ce produit est protégé par les brevets américains : 6,040,967;
6,282,070; 6,381,112; 6,437,953; 6,646,838; 6,657,834; 6,944,001;
7,336,458; 8,054,595; 8,130,480; 6,288,882; 6,717,782; 6,788,173;
8,599,522; 6,088,205; 6,433,978; 6,639,769; 8,599,523, 9,577,420
et les droits étrangers correspondants.
Este producto está cubierto por las patentes de EE.UU.: 6,040,967;
6,282,070; 6,381,112; 6,437,953; 6,646,838; 6,657,834; 6,944,001;
7,336,458; 8,054,595; 8,130,480; 6,288,882; 6,717,782; 6,788,173;
8,599,522; 6,088,205; 6,433,978; 6,639,769; 8,599,523, 9,577,420
y extranjeras correspondientes.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only) www.leviton.com
Ligne d’Assistance Technique : 1 800 824-3005
www.leviton.com
Para Asistencia Técnica llame al: 800-824-3005
(Sólo en EE.UU.) www.leviton.com
DÉCLARATION DE LA FCC
Cet équipement a fait l’objet de tests et a été jugé conforme aux normes en matière
de dispositifs numériques de classe B, en vertu de la partie 15 des règlements de la
FCC, et conforme aux normes en matière de brouillage (NMB) préjudiciable en vertu
de la réglementation du ministère canadien des Communications. Ces normes ont
été élaborées dans le but d’assurer une protection raisonnable contre le brouillage
préjudiciable quand l’équipement est utilisé en milieu résidentiel. Cet équipement
génère, utilise et peut irradier de l’énergie haute fréquence; s’il n’est pas installé et
utilisé conformément aux directives, il peut engendrer des perturbations susceptibles
de brouiller les radiocommunications. Il est cependant impossible de garantir
l’absence de telles perturbations dans une installation donnée. Si cet équipement
est source de parasites au niveau des récepteurs radio ou des téléviseurs, ce qu’on
peut déterminer en le mettant sous et hors tension, on recommande à l’utilisateur de
rectifier la situation en adoptant une ou plusieurs des mesures suivantes :
• réorienter ou déplacer l’antenne réceptrice;
• augmenter la distance entre l’équipement et le récepteur;
• brancher l’équipement à une prise sur un circuit autre que celui où est branché le
récepteur;
• consulter le détaillant ou un technicien expérimenté en matière de radios ou de
téléviseurs.
DÉCLARATION IC
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage
est susceptible d'en compromettre le fonctionnement.
DECLARACIÓN DE LA FCC
Este equipo ha sido probado y encontrado que cumple con los
límites de un producto Digital Clase B, y cumple con el artículo
15 de las reglas FCC. Estos límites están diseñados para dar
protección razonable contra interferencia dañina en instalaciones
residenciales. Este equipo genera, usa y puede irradiar energía
de radio frecuencia y si no se instala y usa de acuerdo con
las instrucciones puede causar interferencia dañina a las
comunicaciones de radio. Sin embargo, no hay garantía que no
ocurra interferencia en una instalación particular. Si este equipo
causa interferencia a la recepción de radio o televisión, la cual
se puede determinar APAGANDO O ENCENDIENDO el equipo, el
usuario puede tratar de corregir la interferencia con una o más de
las siguientes medidas:
• Reoriente o reubique la antena de recepción.
• Aumente la separación entre el equipo y el receptor.
• Conecte el equipo en un contacto en un circuito diferente al del
receptor.
• Para ayuda consulte con el vendedor o técnico con experiencia en
radio/ televisión.
DECLARACIÓN DE IC
Este producto cumple con el estándar(es) RSS exento de licencia de
la Industria de Canadá. La operación está sujeta a dos condiciones:
(1) Este producto no debe causar interferencia dañina, y (2) Este
producto debe aceptar cualquier interferencia recibida, incluyendo
interferencia que puede causar una operación no deseada.
•
TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER
SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER
IS OFF,
before installing, removing or servicing this
equipment.
• This equipment
MUST BE
installed and serviced by an
electrician.
• Replace all doors and covers before connecting power to
this equipment.
• To be installed and/or used in accordance with electrical
codes and regulations.
• To be used in permanently installed and listed enclosures
only.
• Install only on a single phase 120/240 VAC grounded
system in a residential application.
• Do not ground neutral on the load side of the AFCI.
•
DO NOT
reverse-feed or back-wire.
DO NOT
perform a
megger or a high voltage test with the breaker in place.
Remove the breaker prior to high-pot testing of the circuit.
•
PARA EVITAR FUEGO, DESCARGA ELÉCTRICA O MUERTE,
¡INTERRUMPA EL PASO DE ENERGÍA
mediante el interruptor
de circuito o fusible y pruebe que la energía esté desconectada
antes de instalar, sacarlo o hacer mantenimiento a este equipo!
• Este equipo
DEBE
ser instalado y mantenido por un
electricista.
• Reemplace todas las puertas y cubiertas antes de conectar
la energía a este equipo.
• Para instalarse y/o usarse de acuerdo con los códigos
eléctricos y normas apropiadas.
•
Para ser usado sólo en cajas listadas e instaladas
permanentemente.
•
Instálelo en una aplicación residencial sólo en un sistema a
tierra de una fase sencilla de 120/240VCA.
• No conecte el neutro a tierra en el lado de la carga del ICFA.
•
NO
invierta la alimentación o cableado posterior.
NO
haga
un megóhmetro o prueba de alto voltaje con el lugar del
interruptor. Retire el interruptor antes de hacer una prueba
de alta potencia en el circuito.
• Use this branch circuit AFCI breaker with copper or
copper-clad wire only.
•
DO NOT
install this branch circuit AFCI breaker on a
circuit that powers life support equipment because if the
AFCI trips it will shut down the equipment.
• Use este interruptor de circuito derivado ICFA sólo con cable
de cobre o revestido de cobre.
•
NO
instale el interruptor de circuito derivado ICFA en un
circuito que da energía a un equipo para mantener la vida
porque si el ICFA se dispara puede apagar el equipo.
SAFETY INSTRUCTIONS
INSTRUCCIONES DE SEGURIDAD
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING.
MEDIDAS IMPORTANTES DE SEGURIDAD
LEA TODAS LAS INSTRUCCIONES ANTES DE USARLO.
AVERTISSEMENT
•
POUR ÉVITER LES RISQUES D’INCENDIE, DE DÉCHARGE
ÉLECTRIQUE OU D’ÉLECTROCUTION, SECTIONNER LE
COURANT QUI ALIMENTE LE ET S’ASSURER QU’IL EST BIEN
COUPÉ,
avant de procéder à l’installation, à l’entretien ou au
retrait de ce dernier.
• L’installation et l’entretien du
DOIVENT ÊTRE
faits par un
électricien.
• Toutes les portes et tous les couvercles qui abritent le
disjoncteur doivent être fermés avant de le connecter à
l’alimentation.
• Le doit être installé et utilisé conformément aux codes de
l’électricité en vigueur.
• Le produit décrit aux présentes ne peut être installé que dans
des boîtiers homologués, installés de manière permanente.
• Le produit décrit aux présentes ne peut être installé que dans un
système résidentiel monophasé et mis à la terre de 120/240 V c.a.
• Ne pas mettre le neutre à la terre du côté charge du DDAA.
•
NE PAS
inverser l’alimentation ou raccorder par l’arrière.
Retirer le DDAA avant d’effectuer toute mesure de la résistance
d’isolement (Megger) ou tout autre test à tension élevée sur le
circuit.
• N’utiliser le DDAA qu’avec du fil de cuivre ou plaqué cuivre.
•
NE PAS
installer le DDAA sur un circuit qui alimente de
l’équipement de survie parce qu’en cas de déclenchement, ce
circuit sera coupé.
CONSIGNES DE SÉCURITÉ
IMPORTANTES CONSIGNES DE SÉCURITÉ
LIRE TOUTES LES DIRECTIVES AVANT D’UTILISER.
Nos.
LB1xx-AF
INSTALLATION INSTRUCTIONS - ENGLISH
AFCI Branch Circuit Breaker
LIMITED PRODUCT WARRANTY
For Leviton’s limited product warranty, go to
www.leviton.com
. For a printed copy of the warranty you may call
1-800-323-8920
.
Fig. 3
Fig. 2
Fig. 4
Fig. 5
Handle
OFF
Hooks
Hooks
Guides
Guides
Align hooks
and guides
Press until
breaker snaps
into place
Handle
ON
ON
“AF” LED
OFF / TE
S
T
ON
AF
Align guides
Press
Fig. 1
Main Breaker
OFF
ON
B
A
Load Power
(Brass Terminal)
Load Neutral
(Silver Terminal)
TRADEMARK DISCLAIMER:
Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective
owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
Handle Window
“AF” LED
Device Status
Green
OFF
ON
Red
OFF
Overload or short-circuit trip
Red
ON (solid)
Series arc-fault trip
Red
ON (blinking)
1 sec. delay -Parallel arc-fault trip
3 sec. delay -Neutral Miswired
Red
ON (blinking)
.1 sec. delay -Electronics self-test failure
(breaker will be locked out and must be replaced)
White
OFF
Manual OFF
HANDLE OPERATION AND LED DIAGNOSTICS
TERMINATIONS
Termination
Point
Branch
Wire
Wire Gauge
Strip Length
Torque
A (Brass)
Load
Power
#4 AWG - #8 AWG
#10 AWG - #14 AWG
0.40 in.
0.40 in.
45 in-lbs.
35 in-lbs.
B (Silver)
Load
Neutral
#4 AWG - #8 AWG
#10 AWG - #14 AWG
0.40 in.
0.40 in.
45 in-lbs.
35 in-lbs.
C
Ground
#4 AWG - #6 AWG
#8 AWG
#10 AWG - #14 AWG
0.50 in.
0.50 in.
0.50 in.
35 in-lbs.
25 in-lbs.
20 in-lbs.
INSTALLATION
WARNING: TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER
SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER IS OFF,
before
installing, removing or servicing this equipment.
1.
Turn OFF all power to the panelboard by moving the handle of the main breaker to
OFF position
(see fig. 1)
.
NOTE:
If installing the AFCI breaker in a sub-panel turn
power OFF from the breaker located in the main panel.
2.
Remove panel cover
(if necessary)
.
3.
Strip and connect the load power and load neutral conductors to appropriate
terminal lugs
(see fig. 1 and the Terminations table)
.
NOTE:
The load neutral
MUST
be connected to the load neutral terminal,
NOT
the main neutral terminal.
4.
Place handle of the AFCI branch circuit breaker to the OFF position
(see fig. 2)
.
NOTE:
The circuit breaker
CAN NOT
be switched to the ON position until the
installation is complete and power is supplied to the unit.
NOTE:
Leviton AFCI branch circuit breakers contain a Reset Lockout feature that
will prevent putting the breaker in the ON position if the AFCI cannot pass its
internal test, indicating that it may not be able to provide protection in the event of
an arc fault.
5.
Place AFCI branch circuit breaker into the panel as shown
(see fig. 4)
.
6.
Install test instruction label and occupant’s test reminder card
(supplied)
.
7.
Replace all doors and covers before turning ON power to this equipment.
TESTING INSTRUCTIONS
WARNING:
Test monthly to ensure continued protection.
1.
Turn power OFF or unplug all loads downstream of the AFCI branch circuit breaker.
2.
Turn power to the panelboard ON by moving the main breaker to the ON position
(see fig 1)
.
NOTE:
If installed in a sub-panel restore power from the breaker located
in the main panel.
3.
Place handle of the AFCI branch circuit breaker to the OFF position
(see fig. 2)
, then
place the handle to the ON position
(see fig. 3)
.
4.
If the AFCI branch circuit breaker can be put into the ON position, and the handle
window is green, it is working properly.
5.
If the AFCI branch circuit breaker handle cannot be put into the ON position, recheck
wiring and installation, or contact an electrician to make the repairs.
HANDLE OPERATION AND LED DIAGNOSTICS
Each circuit breaker’s rocker handle window displays its operational status using an
intuitive color scheme. In addition, LEDs indicate trip condition and are illuminated even
when the breaker is tripped - because the circuit breaker’s electronics are powered from
the line side instead of the load side, an industry first
(see Handle operation and LED
diagnostics table & fig. 5)
.
In the event that the circuit breaker trips move the handle to the OFF position and then
to the ON position. If the circuit breaker will not reset or trips again turn OFF or unplug
all loads downstream of the circuit breaker and try again. If the circuit breaker still will
not reset, contact an electrician to make repairs.
SAVE THESE INSTRUCTIONS