IMPORTANT SAFETY INSTRUCTIONS -
READ ALL INSTRUCTIONS BEFORE USING.
INSTALLATION INSTRUCTIONS
Nos.
LP8xx, LP8xx-MC, LP8xx-HMC, LP8xx-LMC, LP8xx-5MC, LP8xx-RMC
© 2017 Leviton Mfg. Co., Inc.
Outdoor Meter Main, OH/UG Service Entrance Enclosure
PATENTS PENDING
LIMITED PRODUCT WARRANTY
For Leviton’s limited product warranty, go to
www.leviton.com
. For a printed copy of the warranty you may call
1-800-323-8920
.
WARNING
INSTALLATION
WARNING: TO AVOID FIRE, SHOCK OR DEATH: TURN OFF
POWER SUPPLYING THIS EQUIPMENT, AND CONFIRM
POWER IS OFF,
before installing, removing or servicing
this equipment.
Step 1: Remove meter and wiring compartment covers
a.
Slide
securing latch (A)
upward.
b.
Slide
meter cover (B)
down and out.
c.
Slide
wiring compartment cover (C)
down and out
(fig. 1)
.
Step 2: Bottom feed applications
(Optional)
NOTE:
Install the closing plate (included) to the overhead opening
of the enclosure for bottom feed applications.
NOTE:
For bottom feed applications, wires and conductors
should be run through the wire trough on the left side. For top
feed applications, the wire trough can be removed if desired by
removing the top securing screw, and sliding upward and out.
NOTE:
Before removing any knockouts from the enclosure, consult
the local electrical code to determine the knockout requirements.
a.
Remove
deadfront (P)
by loosening the
securing screw (Q)
and
lifting the
deadfront (P)
off the enclsoure.
b.
To remove
knockouts (D)
, first strike the center of the
knockout.
c.
Pry each
ring (E)
up, one at a time, and grip both ends with a
pair of pliers.
d.
Use the pliers to bend the
rings (E)
until they disconnect from
the enclosure
(fig. 2)
.
Step 3: Enclosure Mounting
Surface Mounting
a.
Remove
mounting knockouts (F)
from the back of the enclosure
(fig. 3).
b.
Use outdoor approved screws or nails (not provided) in the
mounting knockouts (F)
to secure the enclosure to the wall.
Fig. 1
Fig. 2
a.
b.
c.
•
TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER IS OFF,
before installing, removing or servicing this equipment.
• This equipment
MUST BE
installed and serviced by an electrician.
• Replace all doors and covers before connecting power to this equipment.
• To be installed and/or used in accordance with electrical codes and regulations.