FEATURES

• Works with incandescent, magnetic low-voltage, halogen, or neon/cold cathode lighting.

• Low-end adjustment available for setting the minimum brightness level.

• Works with any Dimensions 3200 Series Multizone Controller/Dimmer to extend load capacity on

any zone.

DESCRIPTION

The Leviton Power Extender, Cat. No. PE100-1, will emulate the characteristics of the dimmer that it is
connected to in terms of dimming range and resolution.

Compatibility

Box Mounted Dimmers –

 Must use a 120V, 600W Incandescent version of the following

families: Illumatech, Mural, True Touch, Toggle Touch, Touch Point, and Home Controls.

Monet Installations –

 Must use Monet Magnetic Low-Voltage (requires a Neutral wire).

Architectural Systems –

 Works with all families.

NOTE:

 For dimmers that include a Neutral wire (such as some scene capable dimmers), the dimmer

Neutral wire must be connected.

NOTE:

 The PE100-1 has a minimum level adjustment.

FCC COMPLIANCE STATEMENT

This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.

INSTALLATION INSTRUCTIONS

WARNING: 

TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE

ELECTRICAL CODES AND REGULATIONS.

WARNING: 

IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A

QUALIFIED ELECTRICIAN.

OTHER CAUTIONS:

1.

BOTH LIGHTING FIXTURE AND CONTROLLER MUST BE GROUNDED.

2.

DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.

3.

USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE
USE ONLY DEVICES MARKED CO/ALR OR CU/AL.

NOTE: 

The Power Extender must be installed in a 1900 Box with Raised Cover or a properly

grounded metal 2-gang wall box, 3.5" (8.9 cm) deep 

(refer to Figure 1A, 1B, 2A, and 2B)

. Depending

on the application and the number of connections, more space may be needed. If so, use an
appropriate size box or box extension. 

Refer to Step 4.

TO INSTALL:

1. WARNING: 

TO AVOID FIRE, SHOCK, OR DEATH; 

TURN OFF POWER

 AT CIRCUIT BREAKERS

OR FUSES AND TEST THAT POWER IS OFF BEFORE WIRING!

MORE THAN ONE CIRCUIT BREAKER CAN POWER THIS DEVICE. DISCONNECT “ALL” POWER
SOURCES BEFORE SERVICING CONTROL.

2.

 Remove 1/2" (1.3 cm) of insulation from each circuit conductor in wall box. Make sure that ends of

conductors are straight.

3.

Connect lead wires per appropriate WIRING DIAGRAM and FIGURE 2 as follows: All connections
to the output terminals should be made using #12 AWG wire. Each power terminal can accept up to
two(2) #12 wires. The recommended installation torque is 9.0 in.-lbs. for line voltage connections.

DI-000-PE100-00A-Pilot

Power Extender

Dimming Control

Cat. No. PE100-1

                 Rating: 1920W/VA-120VAC, 50/60Hz

Incandescent

Magnetic Low-Voltage

Neon/Cold Cathode

For more information go to

www.leviton.com

INSTALLATION INSTRUCTIONS

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to

Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of
Canada Ltd., 165 Hymus Blvd., Point Claire, (Quebec),
Canada H9R 1E9).

  This warranty excludes and there is

disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.

4.

Carefully position all wires to provide room in outlet box for Power
Extender. All Power Extenders must have 4-1/2" spacing above
and below each unit for proper ventilation and heat dissipation

(refer to Figure 4)

. Line voltage wiring should be at least 6 ft. away

from sound or electronic equipment wiring. Mount Power Extender
to wall box with “TOP” facing up as follows

 (refer to Figure 3)

.

For Wall Box Mounting:

 Refer to Figure 1A.

For Flush Mounting:

 Refer to Figure 1B.

For Panel Mounting (not shown), 

Proceed as follows

:

a.

The enclosure must be in accordance with all local and national electrical codes.

b.

Leviton DOES NOT recommend using a door to enclose the front of a panel, since this restricts
airflow to the controls.

c.

If mounting multiple controls in an enclosure:

Ambient temperature within an enclosure “MUST REMAIN BETWEEN” 32˚-104˚F (0˚-40˚C).

If not mounting in a metal enclosure, all units “MUST” be mounted in a wall box.

d.

To improve heat dissipation of controls, remove the faceplate from the unit.

5.

Restore power at circuit breaker or fuse.

6.

Turn ON the dimmer.

7.

Using the dimmer control, verify that the load DIMS and BRIGHTENS smoothly and the lamps do
not flicker.

8.

 Attach wallplate by aligning tabs on back of plate with grooves in fins on Power Extender 

(refer to

Figure 1A and Figure 1B)

INSTALLATION IS COMPLETE.

For Technical Assistance Call:

1-800-824-3005 (U.S.A. Only)

1 800 405-5320 (Canada Only)

www.leviton.com

DI-000-PE100-00A-Pilot

1900 Box

Raised Cover
Mounting Screws
(4 Places)

Power

Extender

Power Extender

Wallplate

TO

P

2 Gang Raised Cover

Figure 1A: Surface Mounting

1900 Box

Raised Cover
Mounting Screws
(4 Places)

TO

P

2 Gang Raised Cover

Power Extender

Wallplate

Power

Extender

Figure 1B: Flush Mounting

TOP

TOP

4-1/2" (11.4 cm)
Minimum

4-1/2" (11.4 cm)
Minimum

NEUTRAL

NEUTRAL

LO

AD

HO

T

SWITCH

HO

T

CONTR

OL

Figure 2: End View

Figure 3: Front View

Trim

Adjustment

TOP

Green LED

Figure 4: Front View Spacing

DI-000-PE100-00A-Pilot

6/25/03, 9:49 AM

1

Reviews: